SNMP Reference Guide

MIB Name Agent / Hardware Supported Purpose of the MIB
instrumentation software. This is the primary
MIB for PowerEdge systems.
dcs3fru.mib Server Administrator Provides the information about the system
Field Replaceable Unit (FRU) to SNMP
management applications.
dcstorag.mib Server Administrator Storage
Management
Provides the information about the storage
hardware components and RAID
configurations monitored by Server
Administrator.
iDRAC-SMIv1.mib iDRAC7 Provides information about the SNMP data,
and traps, supported by the iDRAC7. This is
for SMv1.
iDRAC-SMIv2.mib iDRAC7 Provides information about the SNMP data,
and traps, supported by the iDRAC7. This is
for SMv2.
dcs3rmt.mib Dell Remote Access controller 5
(DRAC 5)
Provides information about remote access
components monitored by the Server
Administrator Remote Access Service.
rac_host.mib Remote access out-of-band
agent
Provides information about the components
monitored by the remote access out-of-
band software agent.
DELL-RAC-MIB.txt Chassis Management Controller
(CMC)
Provides information about components
monitored by the Chassis Management
Controller for modular chassis.
DcAsfSrv.mib Baseboard Management
Controller (BMC)
Provides information about Dell server
Platform Event Traps generated by the
Baseboard Management Controller.
For further details see Release Notes for Management Information Base readme_mibs.txt.
Server Administrator Instrumentation MIB
The Server Administrator Instrumentation MIB ( filename 10892.mib ) provides instrumentation data that
allows you to monitor the health of a system with SNMP management applications. It provides:
Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at
key points in the system
Rapid access to detailed fault and performance information gathered by industry standard systems
management agents
Version information for Basic Input/Output System (BIOS), firmware, and operating system
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or
MIB tables that provide related information. The below table describes each Server Administrator
Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server
Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB
11