Users Guide
Minimum Warning 
Threshold
: 900RPM
Maximum Warning 
Threshold
: 3500RPM
Minimum Failure 
Threshold
: 500RPM
Maximum Failure 
Threshold
: 6000RPM
You can use a text editor to insert the time that each block of data was captured. In comparing the two 
snapshots for fan probe 0, you can see that the second report shows several changes. The reading of fan 
RPM has increased by 621 RPM but is still within normal range. Someone has raised the minimum 
warning threshold by 200 RPM and has decreased the maximum warning threshold by 2000 RPM.
Selecting A Format For The CLI Command Output
You can specify a format for the CLI command results. The format determines how the command output 
is displayed. If the command results are directed to a file, the format is captured by the file to which you 
write the command results.
The available formats include:
• List (lst)
• Semicolon-separated values (ssv)
• Table (tbl)
• Custom delimited format (cdv)
The syntax for the formatting option is:
<command> -fmt <format option>
For example, type:
omreport system summary -fmt tbl
or
omreport servermodule summary -fmt tbl
where -fmt tbl specifies table format.
You can combine the formatting option with the option to direct output to a file. For example, type:
omreport system summary -fmt tbl -outa summary.txt
or
omreport servermodule summary -fmt tbl -outa summary.txt
where -fmt tbl specifies table format and -outa specifies that you append the command results to a file 
named summary.txt .
213