Reference Guide
MIB Name Agent / Hardware Supported Purpose of the MIB
iDRAC-SMIv1.mib iDRAC7 and iDRAC 8 Provides information about the SNMP data 
and traps supported by iDRAC7 and iDRAC8. 
This is the SMIv1 version of the iDRAC MIB.
iDRAC-SMIv2.mib iDRAC7 and iDRAC 8 Provides information about the SNMP data 
and traps supported by iDRAC7 and iDRAC8. 
This is the SMIv2 version of the iDRAC MIB.
dcs3rmt.mib Dell Remote Access controller 5 
(DRAC 5)
Provides information about remote access 
components monitored by the Server 
Administrator Remote Access Service.
rac_host.mib Remote access out-of-band 
agent
Provides information about the components 
monitored by the remote access out-of-
band software agent.
DELL-RAC-MIB.txt Chassis Management Controller 
(CMC)
Provides information about components 
monitored by the Chassis Management 
Controller for modular chassis. This MIB is 
the legacy iDRAC MIB. Changes made in this 
MIB are not for iDRAC. iDRAC does not 
support all the objects and traps defined in 
this MIB. The new and more extensive iDRAC 
MIB is available for iDRAC7 and later 
versions.
DcAsfSrv.mib Baseboard Management 
Controller (BMC)
Provides information about Dell server 
Platform Event Traps generated by the 
Baseboard Management Controller.
For further details see Release Notes for Management Information Base readme_mibs.txt.
Server Administrator Instrumentation MIB
The Server Administrator Instrumentation MIB ( filename 10892.mib ) provides instrumentation data that 
allows you to monitor the health of a system with SNMP management applications. It provides:
• Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at 
key points in the system
• Rapid access to detailed fault and performance information gathered by industry standard systems 
management agents
• Version information for Basic Input/Output System (BIOS), firmware, and operating system
• A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or 
MIB tables that provide related information. The below table describes each Server Administrator 
Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server 
Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB 
group number>, where <MIB group number> is the MIB group number assigned to the MIB group. See 
the relevant section for more information about the MIB objects defined in a MIB group.
8