Dell OpenManage SNMP Reference Guide Version 8.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2016 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction................................................................................................................................. 6 What’s New in this release................................................................................................................................................... 6 Supported SNMP Versions..................................................................................................................................................
Remote Flash BIOS Group Table................................................................................................................................ 118 Remote Flash BIOS Variable Values.......................................................................................................................... 120 Port Group...........................................................................................................................................................................
Enclosure Management Module Table..................................................................................................................... 346 Enclosure Management Module Connection Table................................................................................................ 349 Battery Table................................................................................................................................................................ 351 Battery Connection Table..........
1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, Introduction to SNMP Reference Guide, explains the SNMP Reference Guide design.
Managed Object Used in This Document The MIB is divided into several major groups. The following table provides information about the MIB names, name of the agent that uses each MIB and the purpose: MIB Name Agent / Hardware Supported Purpose of the MIB 10892.mib Server Administrator Provides the information about the systems monitored by Server Administrator instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.
Table 1.
Server Administrator Baseboard Management Controller, ASF MIB The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides information about the traps sent by BMC. The Server Administrator BMC MIB structures its MIB objects that provide related information. The BMC MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.. The BMC MIB adheres to ASF 2.0 standard and hence the enterprise ID is wired for management (3183).
Server Administrator Change Management MIB The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications. The following table describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.
Table 5. UUID Table Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Table 6. UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex , uUIDchassisIndex Table 7. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Access Read-only Read-only Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables.
Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard. SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks.
The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community string, which is configured at each SNMP agent and is passed as a part of all SNMP request messages. There is no verification that the requester is actually a member of the specified community.
2 Server Administrator Group The Server Administrator group comprises of the following sections: • • • • • • • • • • • • • • • • • • • Instrumentation MIB Version Group Systems Management Software Group System State Group Chassis Information Group Operating System Group System Resource Group Power Group Thermal Group Remote Flash BIOS Group Port Group Device Group Slot Group Memory Group BIOS Setup Control Group Local Response Agent Group Cost of Ownership Group Cluster Group Baseboard Management Controlle
Management Information Base Major Version Number Name mIBMajorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.1.0 Description Defines the major version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the major version number is 1. A major version number change indicates a major change in object functionality.
https://:<1311 or user specified port number> or https://:<1311 or user specified port number> Systems Management Software The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table. Table 12.
Object ID 1.3.6.1.4.1.674.10892.1.100.6 Description Defines the preferred systems management standard for the systems management software. Syntax SMSSupportedTypes (Systems Management Software Supported Standards) Access Read-only Table 18. Systems Management Software Update Level Name Name systemManagementSoftwareUpdateLevelName Object ID 1.3.6.1.4.1.674.10892.1.100.7 Description Defines the update level of the system management software. Syntax DellString Access Read-only Table 19.
Syntax SMSSNMPAgentFeatureFlags (Systems Management Software SNMP Agent Feature Flags) Access Read-only Table 24. Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software.
System State Group Table The System State Group defines objects in the System State MIB table. System State Table The systemStateGlobalSystemStatus variable provides overall system health status and includes rolled-up (that is, worst) status for Instrumentation and Storage. This variable monitors the overall system health status. It reflects changes to systemStateChassisStatus variable, which represents Instrumentation health status and agentGlobalSystemStatus (dcstorag.
• • systemStateSDCardUnitStatusList systemStateSDCardDeviceStatusList System State Table The following object sets up the System State Table: Table 28. System State Table Name systemStateTable Object ID 1.3.6.1.4.1.674.10892.1.200.10 Description Defines the System State Table. Syntax SEQUENCE OF SystemStateTableEntry Access Not accessible Table 29. System State Table Entry Name systemStateTableEntry Object ID 1.3.6.1.4.1.674.10892.1.200.10.1 Description Defines the System State Table entry.
Description Defines the system status of this chassis. Syntax DellStatus Access Read-only Table 34. System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit.
Syntax DellStatus Access Read-only Table 39. System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.10 Description Defines the status of all power supplies in this chassis. The results are returned as a binary octet string, Each byte of the octet string represents the status of a specific power supply.
Access Read-only Table 44. System State Amperage Status Combined Name systemStateAmperageStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.15 Description Defines the status of all amperage probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only Table 45. System State Amperage Status Details Name systemStateAmperageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 49. System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device. The first byte returned represents the state of the first cooling device, the second byte returned represents the state of the second cooling device, and so on.
Table 54. System State Temperature Status Details Name systemStateTemperatureStatusDetailsly Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25 Description Defines the status of all temperature probes in this chassis. The first byte returned represents the status of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. Syntax Octet String Access Read-only Table 55.
Table 59. System State Chassis Intrusion Status Combined Name systemStateChassisIntrusionStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.30 Description Defines the intrusion status of all intrusion detection devices in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only Table 60. System State Chassis Intrusion Status Details Name systemStateChassisIntrusionStatusDetails Object ID 1.3.
Description Defines the individual state of all AC power cords for any AC power switches in this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on. Syntax Octet String Access Read-only Table 65. System State AC Power Cord Status Combined Name systemStateACPowerCordStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 70. System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only Table 71. System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis. Syntax DellStatus Access Read-only Table 72.
Access Read-only Table 76. System State AC Power Switch Status List Name systemStateACPowerSwitchStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47 Description Lists the status of each AC power switch of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch. The first byte returned represents the status of the first AC power switch, and so on. The bytes have the same definition type as DellStatus.
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.52 Description Defines the combined status of all batteries of this chassis. Syntax DellStatus Access Read-only Table 82. System State Battery Status List Name systemStateBatteryStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53 Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery.
Access Read-only Chassis Information Group The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
Description Defines the capabilities of the chassis. Syntax DellStateCapabilities Access Read-only Table 91. Chassis State Settings Name chassisStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.3 Description Defines the state settings for the chassis. Syntax DellStateSettings Access Read-only Table 92. Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the status of the chassis. Syntax DellStatus Access Read-only Table 93.
Access Read-only Table 97. Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis. Syntax DellString Access Read-only Table 98. Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10 Description Defines the user-assigned asset tag name for this chassis. Syntax DisplayString Access Read-only Table 99.
Table 103. Chassis System Name Name chassisSystemName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15 Description Defines the system name of this chassis. Syntax DellString Access Read-only Table 104. Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Table 105. Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.
Description Defines the status of the connection from the system chassis to an expansion chassis. Syntax DellConnectionStatus (See Connection Status) Access Read-only Table 110. Chassis Fan Control Capabilities Unique Name chassisFanControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.22 Description Defines the capabilities of the fan control function in this chassis. Syntax DellFanControlCapabilities (See Fan Control Capabilities) Access Read-only Table 111.
Access Read-only Table 116. Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Chassis Identification Control Capabilities) Access Read-only Table 117. Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Table 122. Chassis Watchdog Control Settings Unique Name chassiswatchDogControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.34 Description Defines the current settings and the values allowed to be set for the watchdog timer object. Syntax DellWatchDogControlCapabilities (See Watchdog Control Capabilities) Access Read-only Table 123. Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.
Table 128. Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString Access Read-only Table 129. Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41 Description Defines the chassis reseller contact information name. Syntax DisplayString Access Read-only Table 130.
Description Defines the properties of the system. Syntax DellSystemProperties (See System Properties) Access Read-only Table 135. Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47 Description Defines the revision number of the system where zero indicates the original version of the system. The revision number is not available on all systems. Syntax DellUnsigned8BitRange Access Read-only Table 136.
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex , uUIDchassisIndex Table 141. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 142. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Object ID 1.3.6.1.4.1.674.10892.1.300.30 Description Defines the POST Log Table. Syntax SEQUENCE OF PostLogTableEntry Access Not accessible Table 146. POST Log Table Entry Name postLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.30.1 Description Defines the POST Log Table entry. Syntax PostLogTableEntry Access Not accessible Index postLogchassisIndex , postLogRecordIndex Table 147. POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.
Table 151. POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 152. POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Log Format) Access Read-only Event Log Table Table 153.
Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Table 157. Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing the event log. Syntax DellStateCapabilitiesLogUnique Access Read-only Table 158. Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.
Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Table 163. System BIOS Table Name systemBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.300.50 Description Defines the System BIOS Table. Syntax SEQUENCE OF SystemBIOSTableEntry Access Not accessible Table 164. System BIOS Table Entry Name systemBIOSTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.50.
Access Read-only Table 168. System BIOS State Settings Name systemBIOSStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4 Description Defines the state of the system BIOS of this object. Syntax DellStateSettings Access Read-only Table 169. System BIOS Status Name systemBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.5 Description Defines the status of the system BIOS of this object. Syntax DellStatus Access Read-only Table 170.
Table 174. System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10 Description Defines the ending address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only Table 175. System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only Table 176.
Syntax Bit 18 Boot From PC Card (PCMCIA) is supported Bit 19 EDD (Enhanced Disk Drive) Specification is supported Bit 20 Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21 Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in, 360 RPM) is supported Bit 22 Int 13h - 5.25 in / 360 KB Floppy Services are supported Bit 23 Int 13h - 5.25 in /1.2MB Floppy Services are supported Bit 24 Int 13h - 3.
Bit 5 ATAPI ZIP Drive boot is supported Bit 6 1394 boot is supported Bit 7 Smart Battery supported Syntax DellUnsigned8BitRange Access Read-only Table 178. System BIOS Characteristics Ext 2 Name systemBIOSCharacteristicsExt2 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14 Description Defines additional characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 182. Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2 Description Defines the index (one-based) of the firmware in this chassis. Syntax DellObjectRange Access Read-only Table 183. Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Syntax DellFirmwareType Access Read-only Table 188. Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Table 189. Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.9 Description Defines the bitmap of supported methods for firmware update. Syntax DellUnsigned16BitRange Access Read-only Table 190.
Description Defines the Intrusion Table entry. Syntax IntrusionTableEntry Access Not accessible Index intrusionchassisIndex , intrusionIndex Table 194. Intrusion Chassis Index Name intrusionchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 195. Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.
Table 199. Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Table 200. Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Table 201. Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 205. Baseboard Index Name baseBoardIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2 Description Defines the index (one-based) of the base board. Syntax DellObjectRange Access Read-only Table 206. Baseboard State Capabilities Name baseBoardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.
Syntax DellBaseBoardType Access Read-only Table 211. Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Table 212. Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard. Syntax DellString Access Read-only Table 213.
Table 217. Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14 Description Defines the baseboard PPID. Syntax DellString Access Read-only Table 218. Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.15 Description Defines the baseboard asset tag name. Syntax DellString Access Read-only Table 219. Baseboard Express Service Code Name Name baseBoardExpressServiceCodeName Object ID 1.
portable(8) The chassis type is a portable. lapTop(9) The chassis type is a laptop. noteBook(10) The chassis type is a notebook. handHeld(11) The chassis type is a handheld. dockingStation(12) The chassis type is a docking station. allInOne(13) The chassis type is an all-in-one. subNoteBook(14) The chassis type is a subnotebook. spaceSaving(15) The chassis type is a spacesaver. lunchBox(16) The chassis type is a lunch box. mainSystemChassis(17 The chassis type is the main system chassis.
Possible Data Values Meaning of Data Value unknown(1) The LED control capabilities are unknown. alertOnErrorCapable( The LED control can be set to alert on an error condition. 2) alertOnWarningAndErr The LED control can be set to alert on an error and a orCap able(4) warning condition. alertOnWarningOrErro The LED control can be set to alert on an error or a warning rCapa ble(6) condition. Table 225.
Possible Data Values Meaning of Data Value none(0) The LEDs do not have any chassis identification capabilities. unknownCapabilities( The chassis identification control’s capabilities are unknown. 1) enableCapable(2) The chassis identification controls can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The chassis identification control’s capabilities are not ready.
manualFullyCapable(1 The operator can reboot, power on and off the power-cycle 5) capable host, and shut down the operating-system– shutdown capable host. manualRebootWithOSSh The operator can reboot with operating system shutdown. utdow nCapable(16) manualRebootWithoutO The operator can reboot without operating system SShut shutdown. downCapable(32) manualPowerOffWithOS The operator can power off with operating system Shutd ownCapable(64) shutdown.
automaticPowerOffCap Watchdog controls can be set to automatically power off able(16) host. automaticAllExceptNo Watchdog controls can be set to automatically perform all tificationCap functions except notification capable. able(27) automaticFullyCapabl Watchdog controls can be set to automatically perform all e(31) functions. Table 233.
none(0) The power button has no settings capabilities. unknown(1) The power button settings are unknown. enabled(2) The power button state is enabled. disabled(4) The power button state is disabled. Table 237. NMI Button Control Capabilities Variable Name : DellNMIButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no capabilities. unknownCapabilities( The NMI button capabilities are unknown.
processorModule(6) The baseboard type is a processor module. ioModule(7) The baseboard type is an I/O module. memoryModule(8) The baseboard type is a memory module daughterBoard(9) The baseboard type is a daughter board. motherboard(10) The baseboard type is a mother board. processorMemoryModul The baseboard type is a processor or memory module e(11) processorIOModule(12 The baseboard type is a processor or I/O module ) interconnectBoard(13 The baseboard type is an interconnect board. ) Table 241.
hotPlugPCI(11) The firmware type is Hot Plug Peripheral Component Interconnect (PCI) Controller. sensorData(12) The firmware type is Sensor Data Records. peripheralBay(13) The firmware type is Peripheral Bay Backplane. secondaryBackPlane(1 The firmware type is Secondary Backplane for ESM 2 4) systems. secondaryBackPlaneES The firmware type is Secondary Backplane for ESM 3 and 4 M3And4(15) systems. rac(16) The firmware type is Remote Access Controller.
Syntax SEQUENCE OF OperatingSystemMemoryTableEntry Access Not accessible Table 245. Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.20.1 Description Defines the Operating System Memory Table entry. Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Table 246. Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
Description Defines the total physical memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 251. Operating System Memory Available Physical Size Name operatingSystemMemoryAvailablePhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.6 Description Defines the available physical memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 252. Operating System Memory Total Page File Size Name operatingSystemMemoryTotalPageFileSize Object ID 1.
Syntax DellUnsigned64BitRange Access Read-only System Resource Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
Table 260. System Resource Map Index Name systemResourceMapIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2 Description Defines the index of system resource maps in this chassis. Syntax DellObjectRange Access Read-only Table 261. System Resource Map State Capabilities Name systemResourceMapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.3 Description Defines the capabilities of this system map. Syntax DellStateCapabilities Access Read-only Table 262.
Table 266. System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20.1 Description Defines the System Resource Owner Table entry. Variables in this group reference the System Resource Map index. Syntax SystemResourceOwnerTableEntry Access Not accessible Index systemResourceOwnerchassisIndex , systemResourceOwnerIndex Table 267. System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
Syntax DellStatus Access Read-only Table 272. System Resource Owner Interface Type Name systemResourceOwnerInterfaceType Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.6 Description Defines the interface type for this system resource owner. Syntax DellResourceOwnerInterfaceType (Resource Owner Interface Type) Access Read-only Table 273. System Resource Map Index Reference Name systemResourceMapIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
Access Not accessible Index systemResourceIOPortchassisIndex , systemResourceIOPortIndex Table 278. System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 279. System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.
Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only Table 284. System Resource I/O Port Share Disposition Name systemResourceIOPortShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7 Description Defines the share disposition of the system resource I/O port. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 285.
Table 289. System Resource Memory Chassis Index Name systemResourceMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 290. System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only Table 291.
Description Defines the share disposition of the system resource memory. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 295. System Resource Memory Starting Address Name systemResourceMemoryStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.8 Description Defines the 64 bits of the starting address of the system resource memory. Syntax DellUnsigned64BitRange Access Read-only Table 296.
Table 300. System Resource Interrupt Chassis Index Name systemResourceInterruptchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Not accessible Table 301. System Resource Interrupt Index Name systemResourceInterruptIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.2 Description Defines the index (one-based) of this interrupt resource. Syntax DellObjectRange Access Read-only Table 302.
Description Defines the share disposition of the system resource interrupt. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 307. System Resource Interrupt Level Name systemResourceInterruptLevel Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.8 Description Defines the interrupt request (IRQ) level of the system resource interrupt. Syntax DellUnsigned32BitRange Access Read-only Table 308.
Table 312. System Resource DMA Chassis Index Name systemResourceDMAchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 313. System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only Table 314.
Description Defines the share disposition of the system resource DMA. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 319. System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA. Syntax DellUnsigned32BitRange Access Read-only Table 320.
typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 324.
dmaIsOther(1) The DMA bus master capability is not one of the following: dmaIsUnknown(2) The DMA bus master capability is unknown. dmaIsNotABusmaster(3) The DMA does not have bus master capability. Table 329. Resource DMA Transfer Width Variable Name: DellResourceDMATransferWidth Data Type: Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther(1) The DMA transfer width is not one of the following: dmaTransferWidthIsunknown(2 ) The DMA transfer width is unknown.
Table 331. Power Unit Table Entry Name powerUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.10.1 Description Defines the Power Unit Table entry. Syntax DellObjectRange Access Read-only Index powerUnitchassisIndex, powerUnitIndex Table 332. Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 333.
Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy. Syntax DellString Access Read-only Table 338. Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7 Description Defines the name of the power unit in this chassis. Syntax DellString Access Read-only Table 339. Power Unit Status Name powerUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Table 344. Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (Power Supply State Capabilities Unique) Access Read-only Table 345.
Syntax DellString Access Read-only Table 350. Power Supply Maximum Input Voltage Name powerSupplyMaximumInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.9 Description This attribute defines the maximum input voltage of the power supply (in Volts). Syntax DellSigned32BitRange Access Read-only Table 351. Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Access Read-only Table 356. Power Supply FQDD Name powerSupplyFQDD Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.15 Description Fully qualified device descriptor (FQDD) of the power supply. Syntax FQDDString Access Read-only Table 357. Power Supply Current Input Voltage Name powerSupplyCurrentInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.16 Description This attribute defines the current input voltage to the power supply (in Volts).
Access Read-only Table 362. Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe. Syntax DellStateCapabilities Access Read-only Table 363. Voltage Probe State Settings Name voltageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.4 Description Defines the state and settings of the voltage probe. Syntax DellStateSettings Access Read-only Table 364.
Table 368. Voltage Probe Upper Nonrecoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.9 Description Defines the value of the voltage probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 369. Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.10 Description Defines the value of the voltage probe’s upper critical threshold.
Description Defines the probe capabilities of the voltage probe. Syntax DellProbeCapabilities Access Read-only Table 375. Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16 Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute.
Description Defines the index of amperage probes in this chassis. Syntax DellObjectRange Access Read-only Table 380. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Table 381. Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Table 385. Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis. Syntax DellString Access Read-only Table 386. Amperage Probe Upper Nonrecoverable Threshold Name amperageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
Access Read-only Table 391. Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.14 Description Defines the value of the amperage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 392. Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.15 Description Defines the probe capabilities of the amperage probe.
, aCPowerSwitchIndex Table 396. AC Power Switch Chassis Index Name aCPowerSwitchChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.1 Description Defines the index (one-based) of the chassis containing this AC power switch. Syntax DellObjectRange Access Read-only Table 397. AC Power Switch Index Name aCPowerSwitchIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.2 Description Defines the index (one-based) of this AC power switch. Syntax DellObjectRange Access Read-only Table 398.
Access Read-only Table 402. AC Power Switch Name Name aCPowerSwitchName Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7 Description Defines the name of this AC power switch. Syntax DellString Access Read-only Table 403. AC Power Switch Redundancy Mode Name aCPowerSwitchRedundancyMode Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.8 Description Defines the redundancy mode of this AC power switch. Syntax DellACPowerSwitchRedundancyMode Access Read-only Table 404.
Table 407. AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.1 Description Defines the index (one-based) of the chassis containing this AC power cord. Syntax DellObjectRange Access Read-only Table 408. AC Power Cord Index Name aCPowerCordIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.2 Description Defines the index (one-based) of this AC power cord. Syntax DellObjectRange Access Read-only Table 409.
Description Defines the location name of this AC power cord. Syntax DellString Access Read-only Battery Table Table 414. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 415. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry.
Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-only Table 420. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Table 421. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6 Description Defines the reading of the battery. Syntax DellBatteryReading (Battery Reading) Access Read-only Table 422.
Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 426. Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.2 Description Defines the index (one-based) of the power usage information. Syntax DellObjectRange Access Read-only Table 427. Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Access Read-only Table 432. Power Usage Cumulative Wattage Start Date Name Name powerUsageCumulativeWattageStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.8 Description Defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute. Syntax DellDateName Access Read-only Table 433. Power Usage Peak Watts Name powerUsagePeakWatts Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Syntax DellDateName Access Read-only Table 438. Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.14 Description Defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured. Syntax DellDateName Access Read-only Table 439. Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts).
Access Read-only Table 444. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Table 445. Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Description Defines the index (one-based) of the power profile information. Syntax DellObjectRange Access Read-only Table 450. Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3 Description Defines the supported power profiles. Syntax DellPowerProfileType Access Read-only Table 451. Power Profile Setting Name powerProfileSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.4 Description Defines the power profile setting.
Description Defines the custom memory power and performance management setting for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Table 456. Power Profile Custom Fan Management Capabilities Name powerProfileCustomFanManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.9 Description Defines the custom fan power and performance management capabilities that are available for the Custom power profile.
acSwitchIsON(64) The power supply is indicating that the AC power switch is on. onlineandAcSwitchIsON (66) The power supply is online and indicating that the AC power supply switch capability is activated. acPowerIsON(128) The power supply is indicating that the AC power is on. onlineAndAcPowerIsON (130) The power supply is online and indicating that the AC power is on. onlineAndPredictiveFail ure(210) The power supply is online and indicating that it has a problem.
processorMissing(3) The power supply configuration error type is processor missing. Table 463. Voltage Probe Type Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1) The voltage probe type is not one of the following: voltageProbeTypeIsUnknown(2) The voltage probe type is unknown (not known or not monitored). voltageProbeTypeIs1Point5Volt (3) The voltage probe type is a 1.5-volt (V) probe.
amperageProbeTypeIsIO(9) The amperage probe type is an I/O amperage probe. amperageProbeTypeIsCore(10) The amperage probe type is a core amperage probe. amperageProbeTypeIsFLEA(11) The amperage probe type is a FLEA (standby) amperage probe. amperageProbeTypeIsBattery(12) The amperage probe type is a battery amperage probe. amperageProbeTypeIsTerminator(13) The amperage probe type is a Small Computer System Interface (SCSI) termination amperage probe.
inputSourceCord2Return(16) Input source is AC power cord 2, with return. inputSourceShared(32) Input source is shared. Table 469. AC Power Switch Redundancy Mode Variable Name: DellACPowerSwitchRedundancyMode Data Type: Integer Possible Data Values Meaning of Data Value nonRedundant(1) The AC power switch is not expecting redundancy. redundant(2) The AC power switch is expecting redundancy. Table 470.
enable(1) Power cap can be enabled. disable(2) Power cap can be disabled. Table 474. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Table 475. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible.
mhz800(8) Memory power and performance is 800 MHz. minPower(16) Memory power and performance management type is Minimum Power. Table 478. Fan Power Performance Management Type Variable Name: DellFanPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Fan power and performance management type is Maximum Performance.
Table 481. Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Table 482. Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units. Syntax DellObjectRange Access Read-only Table 483.
Description Defines the cooling unit name in this chassis. Syntax DellString Access Read-only Table 488. Cooling Unit Status Name coolingUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.8 Description Defines the status of the cooling unit in this chassis. Syntax DellStatus Access Read-only Cooling Device Table Table 489. Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table.
Table 493. Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Table 494. Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device. Syntax DellStateSettings Access Read-only Table 495.
Access Read-only Table 499. Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9 Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 500. Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10 Description Defines the value of the fan’s upper critical threshold.
Table 505. Cooling Device Cooling Unit Index Reference Name coolingDevicecoolingUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.15 Description Defines the index for the associated system cooling unit in this chassis. Syntax DellObjectRange Access Read-only Table 506. Cooling Device Subtype Name coolingDeviceSubType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.16 Description Defines the cooling device subtype.
Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex , temperatureProbeIndex Table 511. Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 512. Temperature Probe Index Name temperatureProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.6 Description Defines the value of the temperature probe. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 517.
Table 522. Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12 Description Defines the user-assigned value of the temperature probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-only Table 523. Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored). coolingDeviceTypeIsAFan(3) The cooling device type is a fan. coolingDeviceTypeIsABlower(4) The cooling device type is a centrifugal blower. coolingDeviceTypeIsAChipFan(5) The cooling device type is a fan on an integrated circuit.
temperatureProbeTypeIsDiscrete(16) The temperature probe subtype is a temperature probe with discrete reading. Table 531. Temperature Probe Discrete Reading Variable Name: DellTemperatureDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value temperatureIsGood(1) The temperature probe discrete reading is good. temperatureIsBad(2) The temperature probe discrete reading is bad.
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system. Syntax DellObjectRange Access Read-only Table 536. Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.3 Description Defines the capabilities of the remote BIOS update hardware on this system.
Syntax DellUnsigned32BitRange Access Read-only Remote Flash BIOS Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 542. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown.
completionCodeIsNoExternalPower(10) An external power adapter must be connected. completionCodeIsNo12VoltSet(11) 12 volts (V) could not be set. completionCodeIsNo12VoltRemoval(12) 12 V could not be removed. completionCodeIsFlashMemoryFailed (13) A flash memory failure occurred. completionCodeIsGeneralFailure(14) A general failure occurred. completionCodeIsDataMiscompare(15) A data miscompare error occurred. completionCodeIsNoImageFound(16) The flash BIOS image could not be found in memory.
Table 547. Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 548. Pointing Port Index Name pointingPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.2 Description Defines the index of the pointing ports in this chassis. Syntax DellObjectRange Access Read-only Table 549.
Description Defines the connector type of the pointing port. Syntax DellPointingPortConnectorType (See Pointing Port Connector Type) Access Read-only Table 554. Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Table 555. Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.
Table 559. Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis. Syntax DellObjectRange Access Read-only Table 560. Keyboard Port State Capabilities Name keyboardPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.3 Description Defines the capabilities of the keyboard port. Syntax DellStateCapabilities Access Read-only Table 561.
Description Defines the name of the keyboard port. Syntax DellString Access Read-only Table 566. Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Table 567. Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.
Table 571. Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port. Syntax DellStateCapabilities Access Read-only Table 572. Processor Port State Settings Name processorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.4 Description Defines the state and settings of the processor port. Syntax DellStateSettings Access Read-only Table 573.
Description Defines the BIOS connector type of the processor port. Syntax DellGenericPortConnectorType Access Read-only Memory Device Port Table Table 578. Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Table 579. Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.
Table 583. Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port. Syntax DellStateSettings Access Read-only Table 584. Memory Device Port Status Name memoryDevicePortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.5 Description Defines the status of the memory device port. Syntax DellStatus Access Read-only Table 585.
Description Defines the index to the associated physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 590. Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any).
Syntax DellObjectRange Access Read-only Table 595. Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Table 596. Monitor Port State Settings Name monitorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.4 Description Defines the state of the monitor port. Syntax DellStateSettings Access Read-only Table 597.
Table 601. Monitor Port BIOS Connector Type Name monitorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.9 Description Defines the name of the BIOS connector type of the monitor port. Syntax DellGenericPortConnectorType Access Read-only Small Computer System Interface (SCSI) Port Table Table 602. Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table.
Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only Table 607. SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port. Syntax DellStatus Access Read-only Table 608. SCSI Port Status Name sCSIPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.5 Description Defines the status of the SCSI port.
Access Read-only Parallel Port Table Table 613. Parallel Port Table Name parallelPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.70 Description Defines the Parallel Port Table. Syntax IntegerParallelPortTableEntry Access Not accessible Table 614. Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry.
Table 618. Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-only Table 619. Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Table 620.
Description Defines the capabilities of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 625. Parallel Port Base I/O Address Name parallelPortBaseIOAddress Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.11 Description Defines the Base Input/Output (I/O) address of the parallel port. Syntax DellUnsigned64BitRange Access Read-only Table 626. Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.
Table 630. Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 631. Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis. Syntax DellObjectRange Access Read-only Table 632.
Description Defines connector type of the serial port. Syntax DellSerialPortConnectorType Access Read-only Table 637. Serial Port Name Name serialPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8 Description Defines the name of the serial port. Syntax DellString Access Read-only Table 638. Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.
Syntax IntegerUSBPortTableEntry Access Not accessible Table 643. USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex , uSBPortIndex Table 644. USB Port Chassis Index Name uSBPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 649. USB Port Security State Name uSBPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.6 Description Defines the security settings of the USB port. Syntax DellPortSecurityState Access Read-only Table 650. USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only Table 651.
connectorPortTypeIsMicroDIN(10) The pointing port connector type is micro Deutsche Industrie Norm (DIN). connectorPortTypeIsAccessBusUSB The pointing port connector type is Access (11) Bus USB. connectorPortTypeIsPC98(12) The port connector type is a PC-98. Table 653.
connectorPortTypeIsUnknown(2) The memory device port connector type is unknown. connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM). connectorPortTypeIsSIP(4) The memory device port connector type is a SIP. connectorPortTypeIsAChip(5) The memory device port connector type is a chip. connectorPortTypeIsDIP(6) The memory device port connector type is a dual in-line package (DIP).
Device Tables The following management information base (MIB) tables define objects in the Device Group: • • • • • • • • • • • • • • Pointing Device Table Keyboard Device Table Processor Device Table Processor Device Status Table Cache Device Table Memory Device Table Memory Device Mapped Address Table Generic Device Table PCI Device Table PCI Device Configuration Space Table Network Device Table Managed System Services Device Table SD Card Unit Table SD Card Device Table Pointing Device Table Table 658.
Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.2 Description Defines the index of the pointing device in this chassis. Syntax DellObjectRange Access Read-only Table 662. Pointing Device State Capabilities Name pointingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.3 Description Defines the capabilities of the pointing device. Syntax DellStateCapabilities Access Read-only Table 663. Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.
Syntax DellUnsigned8BitRange Access Read-only Keyboard Device Table Table 668. Keyboard Device Table Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20 Description Defines the Keyboard Device Table. This table references the Keyboard Port Index (Keyboard Port Index). Syntax SEQUENCE OF KeyboardDeviceTableEntry Access Not accessible Table 669. Keyboard Device Table Entry Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20.
Table 673. Keyboard Device State Settings Name keyboardDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.4 Description Defines the state of the keyboard device. Syntax DellStatesSettings Access Read-only Table 674. Keyboard Device Status Name keyboardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5 Description Defines the status of the keyboard device. Syntax DellStatus Access Read-only Table 675.
Table 679. Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry. Syntax ProcessorDeviceTableEntry Access Not accessible Index processorDevicechassisIndex , processorDeviceIndex Table 680. Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 685. Processor Port Index Reference Name processorPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6 Description Defines the index to the associated processor port in this chassis. Syntax DellObjectRange Access Read-only Table 686. Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device.
Table 691. Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 692. Processor Device External Clock Speed Name processorDeviceExternalClockSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Table 697. Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18 Description Defines the number of processor cores enabled for the processor device. Syntax DellUnsigned32BitRange Access Read-only Table 698. Processor Device Thread Count Name processorDeviceThreadCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.19 Description Defines the number of processor threads detected for the processor device.
Table 701. Processor Device Extended Settings Name processorDeviceExtendedSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22 Description This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Table 706. Processor Device Status Table Entry Name processorDeviceStatusTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1 Description Defines the Processor Device Status Table Entry. Syntax ProcessorDeviceStatusTableEntry Access Not accessible Index processorDeviceStatusChassisIndex , processorDeviceStatusIndex Table 707. Processor Device Status Chassis Index Name processorDeviceStatusChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.
Syntax DellStatus Access Read-only Table 712. Processor Device Status Reading Name processorDeviceStatusReading Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6 Description Defines the reading of the processor device status probe. Syntax DellProcessorDeviceStatusReading Access Read-only Table 713. Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.
Table 717. Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 718. Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Table 719.
Description Defines the type of cache device. Syntax DellCacheDeviceType (See Cache Device Type) Access Read-only Table 724. Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Cache Device Location) Access Read-only Table 725. Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.
Syntax DellUnsigned32BitRange Access Read-only Table 730. Cache Device Speed Name cacheDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.14 Description Defines the speed of the cache device in nanoseconds. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 731. Cache Device Write Policy Name cacheDeviceWritePolicy Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.15 Description Defines the write policy of the cache device.
Table 736. Cache Device Current Type Name cacheDeviceCurrentType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20 Description Defines the current type of SRAM for the cache device. Syntax DellCacheDeviceSRAMType (See Cache Device Static Random-Access Memory (SRAM) Type) Access Read-only Memory Device Table Table 737. Memory Device Table Name memoryDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.50 Description Defines the Memory Device Table.
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device. Syntax DellStateCapabilities Access Read-only Table 742. Memory Device State Settings Name memoryDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.4 Description Defines the state of the memory device. Syntax DellStateSettings Access Read-only Table 743. Memory Device Status Name memoryDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.9 Description Defines the total number of Error Checking and Correction (ECC) errors detected by the memory device. Writing a 0 (zero) to this variable resets the devices error counts. Syntax DellSigned32BitRange Access Read-only Table 748. Memory Device Bank Location Name Name memoryDeviceBankLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.10 Description Defines the bank location name of the memory device.
Table 753. Memory Device Speed Name memoryDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.15 Description Defines the attribute defines the maximum capable speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed. Syntax DellUnsigned32BitRange Access Read-only Table 754. Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device.
Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks. Syntax DellMemoryDeviceFailureModes Access Read-only Table 759. Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.21 Description Defines the manufacturer of the memory device.
Value Meaning deviceRankIsUnknown(1) Rank is unknown deviceRankIsSingle(2) Rank is Single deviceRankIsDual(4) Rank is Dual deviceRankIsQuad(8) Rank is Quad deviceRankIsOctal(16) Rank is Octal deviceRankIsHexa(32) Rank is Hexa Syntax DellMemoryDeviceRank Access Read-only Table 765. Memory Device Extended Size NOTE: This attribute replaces the memoryDeviceSize. Name memoryDeviceExtendedSize Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Table 769. Memory Device Mapped Address Table Entry Name memoryDeviceMappedAddressTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1 Description Defines the Memory Device Mapped Address Table entry. Syntax MemoryDeviceMappedAddressTableEntry Access Not accessible Index memoryDeviceMappedAddresschassisIndex , memoryDeviceMappedAddressIndex Table 770. Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Syntax DellStatus Access Read-only Table 775. Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Table 776. Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Syntax DellUnsigned64BitRange Access Read-only Generic Device Table Table 781. Generic Device Table Name genericDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.70 Description Defines the Generic Device Table. Syntax SEQUENCE OF GenericDeviceTableEntry Access Not accessible Table 782. Generic Device Table Entry Name genericDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1 Description Defines the Generic Device Table entry.
Table 786. Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device. Syntax DellStateSettings Access Read-only Table 787. Generic Device Status Name genericDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5 Description Defines the status of the generic device. Syntax DellStatus Access Read-only Table 788.
Table 792. PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1 Description Defines the PCI Device Table entry. Syntax PCIDeviceTableEntry Access Not accessible Index pCIDevicechassisIndex , pCIDeviceIndex Table 793. PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 794.
Access Read-only Table 798. PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.6 Description Defines the index number of the system slot that this PCI device is in. Syntax DellObjectRange Access Read-only Table 799. PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis.
PCI Device Configuration Space Table Table 804. PCI Device Configuration Space Table Name pCIDeviceConfigurationSpaceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.82 Description Defines the PCI Device Configuration Table. Syntax SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry Access Not accessible Table 805. PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.82.
Description Defines the state of the PCI device configuration. Syntax DellStateSettings Access Read-only Table 810. PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only Table 811. PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.
Access Read-only Network Device Table Table 816. Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table. Syntax SEQUENCE OF NetworkDeviceTableEntry Access Not accessible Table 817. Network Device Table Entry Name networkDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1 Description Defines the Network Device Table Entry.
Table 821. Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.4 Description Defines the connection status of the network device. Syntax DellNetworkDeviceConnectionStatus (See Network Device Connection Status) Access Read-only Table 822. Network Device Description Name Name networkDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5 Description Defines the description of the network device.
Description Defines the version of the driver for the network device. Syntax DellString Access Read-only Table 828. Network Device IP Address Name networkDeviceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.11 Description Defines the IP address of the network device. Syntax IpAddress Access Read-only Table 829. Network Device IP Subnet Mask Name networkDeviceIPSubnetMask Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Access Read-only Table 834. Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17 Description Defines the PCI bus number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 835. Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 836.
Table 840. Network Device TOE Capability Flags Name networkDeviceTOECapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23 Description Defines the TCP/IP Offload Engine (TOE) capability flags of the network device. Syntax DellNetworkDeviceTOECapabilityFlags (See Network Device TOE Capability Flags) Access Read-only Table 841. Network Device TOE Enabled Name networkDeviceTOEEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.29 Description Defines the capabilities of the network device. Syntax DellNetworkDeviceCapabilities (See Network Device Capabilities) Access Read-only Table 847. Network Device NParEP Enabled Name networkDeviceNParEPEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.30 Description Defines if NParEP mode is enabled for the network device.
Table 851. Managed System Services Device Index Name managedSystemServicesDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.2 Description Defines the index (one-based) of the managed system services device. Syntax DellObjectRange Access Read-only Table 852. Managed System Services Device Status Name managedSystemServicesDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3 Description Defines the status of the managed system services device.
Table 857. SD Card Unit Table Entry Name sdCardUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1 Description Defines the SD Card Unit Table Entry. Syntax SdCardUnitTableEntry Access Not accessible Index sdCardUnitChassisIndex , sdCardUnitIndex Table 858. SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit.
Access Read-only Table 863. SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy. Syntax DellObjectRange Access Read-only Table 864. SD Card Unit Name Name sdCardUnitName Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.7 Description Defines the name of the SD Card unit. Syntax DellString Access Read-only Table 865.
Table 868. SD Card Device Chassis Index Name sdCardDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card device. Syntax DellObjectRange Access Read-only Table 869. SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device. Syntax DellObjectRange Access Read-only Table 870.
Description Defines the location of the SD Card device. Syntax DellString Access Read-only Table 875. SD Card Device Card Present Name sdCardDeviceCardPresent Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.8 Description Defines whether the SD Card is present for the SD Card device. Syntax DellBoolean Access Read-only Table 876. SD Card Device Card State Name sdCardDeviceCardState Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.9 Description Defines the state of the SD Card.
Access Read-only Device Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 881. Pointing Device Type Variable Name: DellPointingDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAMouse(3) Device type is a mouse. deviceTypeIsATrackBall( Device type is a track ball.
processorDisabled(25 6) The processor is disabled terminatorPresent(51 2) The terminator is Present processorThrottled(1 024) The processor is throttled Table 884. Processor Device Type Variable Name:DellProcessorDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) The processor device type is not one of the following values: deviceTypeIsUnknown( 2) The processor device type is unknown.
processorUpgradeIsBy SlotM(12) Upgrade is by Slot M. processorUpgradeIsBy Scoket423(13) Upgrade is by Socket 423. processorUpgradeIsBy SocketA(14) Upgrade is by Socket A (Socket 462). processorUpgradeIsBy Socket478(15) Upgrade is by Socket 478. processorUpgradeIsBy Socket754(16) Upgrade is by Socket 754. processorUpgradeIsBy Socket940(17) Upgrade is by Socket 940. processorUpgradeIsBy Socket939(18) Upgrade is by Socket 939. processorUpgradeIsBy SocketmPGA604(19) Upgrade is by Socket mPGA604.
deviceFamilyIs80387( 9) The processor family is 80387. deviceFamilyIs80487( 10) The processor family is 80487. deviceFamilyIsPentiu m(11) The processor family is Intel Pentium. deviceFamilyIsPentiu mPro(12) The processor family is Pentium Pro. deviceFamilyIsPentiu m2(13) The processor family is Pentium II. deviceFamilyIsPentiu mMMX(14) The processor family is Pentium MMX. deviceFamilyIsCelero n(15) The processor family is Celeron. deviceFamilyIsXeon(1 6) The processor family is Xeon.
deviceFamilyIsPowerP C603Plus (35) The processor family is Power PC 603+. deviceFamilyIsPowerP C604(36) The processor family is Power PC 604. deviceFamilyIsPowerP C620(37) The processor family is Power PC 620. deviceFamilyIsPowerP Cx704(38) The processor family is Power PC x704. deviceFamilyIsPowerP C750(39) The processor family is Power PC 750. deviceFamilyIsIntelC oreDuo(40) The processor family is Intel Core Duo.
deviceFamilyIsMIPS(6 4) The processor family is MIPS deviceFamilyIsMIPSR4 000(65) The processor family is MIPS R4000. deviceFamilyIsMIPSR4 200(66) The processor family is MIPS R4200. deviceFamilyIsMIPSR4 400(67) The processor family is MIPS R4400. deviceFamilyIsMIPSR4 600(68) The processor family is MIPS R4600. deviceFamilyIsMIPSR1 0000(69) The processor family is MIPS R10000. deviceFamilyIsSPARC( 80) The processor family is SPARC.
deviceFamilyIsWeite k(128) The processor family is Weitek. deviceFamilyIsIntelC eleronM(130) The processor family is Intel Celeron M. deviceFamilyIsAMDAth lon64(131) The processor family is AMD Athlon 64. deviceFamilyIsAMDOpt eron(132) The processor family is AMD Opteron. deviceFamilyIsAMDSem pron(133) The processor family is AMD Sempron. deviceFamilyIsAMDTur ion64Mobile(134) The processor family is AMD Turion 64 Mobile Technology.
deviceFamilyIsDualCo reIntelXeon3000(162) The processor family is Dual-Core Intel Xeon processor 3000 Series. deviceFamilyIsQuadCo reIntelXeon5300(163) The processor family is Quad-Core Intel Xeon processor 5300 Series. deviceFamilyIsDualCo reIntelXeon5100(164) The processor family is Dual-Core Intel Xeon processor 5100 Series. deviceFamilyIsDualCo reIntelXeon5000(165) The processor family is Dual-Core Intel Xeon processor 5000 Series.
deviceFamilyIsIntelC oreSolo (189) The processor family is Intel Core Solo processor. deviceFamilyIsIntelC ore2(190) The processor family is Intel Core 2 processor. deviceFamilyIsIntelC ore2Duo (191) The processor family is Intel Core 2 Duo processor. deviceFamilyIsIntelC ore2Solo (192) The processor family is Intel Core2 Solo processor. deviceFamilyIsIntelC ore2Extreme(193) The processor family is Intel Core2 Extreme processor.
deviceFamilyIsQuadCo reIntelXeo n3xxx(216) The processor family is Quad-Core Intel Xeon processor 3xxx Series. deviceFamilyIsVIANan o(217) The processor family is VIA Nano. deviceFamilyIsDualCo reIntelXeo n5xxx(218) The processor family is Dual-Core Intel Xeon processor 5xxx Series. deviceFamilyIsQuadCo reIntelXeo n5xxx(219) The processor family is Quad-Core Intel Xeon processor 5xxx Series.
deviceFamilyIsAMDOpt eron4200 (61) The processor family family is AMD Opteron 4200 Series Processor. Table 887. Cache Device Type Variable Name:DellCacheDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) System cache type is not one of the following: deviceTypeIsUnknown( 2) System cache type is unknown. deviceTypeIsInstruct ion(3) System cache type is instruction. deviceTypeIsData(4) System cache type is data.
Table 890. Cache Device Status State Variable Name:DellCacheDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 891.
deviceAssociativityI sEightWaySetAssociat ive(7) Device is eight-way set associative. deviceAssociativityI sSixteenWaySetAssoci ative(8) Device is sixteen-way set associative. deviceAssociativityI s12WaySetAssociativ e(9) Device is 12-way Set-Associative. deviceAssociativityI s24WaySetAssociativ e(10) Device is 24-way Set-Associative. deviceAssociativityI s32WaySetAssociativ e(11) Device is 32-way Set-Associative. deviceAssociativityI s48WaySetAssociativ e(12) Device is 48-way Set-Associative.
deviceSRAMTypeIsAsyn chronous(7) Device SRAM type is asynchronous. Table 895. Memory Device Type Form Factor Variable Name:DellMemoryDeviceFormFactor Data Type:Integer Possible Data Values Meaning of Data Value deviceFormFactorIsOt her(1) Device form factor is not one of the following: deviceFormFactorIsUn known(2) Device form factor is unknown. deviceFormFactorIsSI MM(3) Device form factor is SIMM. deviceFormFactorIsSI P(4) Device form factor is SIP.
deviceTypeIsSRAM(6) Device type is SRAM. deviceTypeIsRAM(7) Device type is RAM. deviceTypeIsROM(8) Device type is ROM. deviceTypeIsFLASH(9) Device type is FLASH. deviceTypeIsEEPROM(1 0) Device type is EEPROM. deviceTypeIsFEPROM(1 1) Device type is FEPROM. deviceTypeIsEPROM(12 ) Device type is EPROM. deviceTypeIsCDRAM(13 ) Device type is CDRAM. deviceTypeIs3DRAM(14 ) Device type is 3DRAM. deviceTypeIsSDRAM(15 ) Device type is SDRAM. deviceTypeIsSGRAM(16 ) Device type is SGRAM.
deviceTypeDetailIsED O(512) The detailed device type is EDO. deviceTypeDetailIsWi ndowDRAM (1024) The detailed device type is Window DRAM. deviceTypeDetailIsCa cheDRAM (2048) The detailed device type is Cache DRAM. deviceTypeDetailIsNo nVolatile (4096) The detailed device type is Non-volatile. deviceTypeDetailIsRe gistered (8192) The detailed device type is registered. deviceTypeDetailIsNo nRegister ed(16384) The detailed device type is nonregistered. Table 898.
Table 900. Network Device Connection Status Variable Name:DellNetworkDeviceConnectionStatus Data Type:Integer Possible Data Values Meaning of Data Value unknown(0) Unable to determine connection status. connected(1) Media reports that device is connected. disconnected(2) Media reports that device is disconnected. driverBad(3) Driver cannot be opened to determine status. driverDisabled(4) Driver is disabled. hardwareInitalizing( 10) Hardware is initializing.
Table 903. Network Device RDMA Capability Flags Variable Name:DellNetworkDeviceRDMACapabilityFlags Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for RDMA capability is not supported. unknown(1) Querying for RDMA capability is supported but query returned an error. available(2) Device has RDMA capability. notAvailable(4) Device does not have RDMA capability.
Table 906. Network Device NParEPEnabled Variable Name:DellNetworkDeviceNParEPEnabled Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value Disabled(1) Device does not support NParEP mode. enabled(2) Device supports NParEP mode. unknown(3) Device does not recognize NParEP mode. Table 907.
Table 911. SD Card Device Card State Variable Name:DellSDCardDeviceCardState Data Type:Integer Possible Data Values Meaning of Data Value none(0) SD card state is none of the following states. present(1) Device is present. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected.
Syntax IntegerSystemStateTableEntry Access Not accessible Table 914. System Slot Table Entry Name systemSlotTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1 Description Defines the System Slot Table entry. Syntax IntegerSystemSlotTableEntry Access Not accessible Index systemSlotchassisIndex , systemSlotIndex Table 915. System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis.
Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5 Description Defines the status of the system slot. Syntax DellStatus Access Read-only Table 920. System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only Table 921. System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot.
Syntax DellUnsigned32BitRange Access Read-only Table 926. System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot. Syntax DellSystemSlotHotPlugBusWidth (Hot-Plug Bus Width) Access Read-only Table 927. System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
systemSlotHotPlugIsUnknown (1) The system slot’s capabilities are unknown. systemSlotCanProvide5Volts (128) The system slot can provide a 5-volt (V) supply. systemSlotCanProvide3Point 3Volts(256) The system slot can provide a 3.3-V supply. systemSlotCanSignalIfShared (512) The system slot’s opening, if shared with another slot, can be detected. systemSlotCanSupportCard16 (1024) The system slot can support PC Card-16. systemSlotCanSupportCardBus (2048) The system slot can support CardBus.
supportsPMEand3P3Vand5VhasAdapter OnandisHotPluggable(16806) The system slot supports PME, supplies 3.3 V, and supplies 5 V. The adapter is on and the system slot is hot pluggable. supportsPMEand3P3VIsSharedand5Vhas AdapterOnandisHotPluggable(17316) The system slot supports PME, supplies 3.3 V, supplies 5 V, and shares a slot opening. The adapter is on and the system slot is hot pluggable. Table 931.
systemSlotIsPCIExpressGen2X2(173) . The system slot type is PCI Express Gen 2 x2 systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express Gen 2 x4. systemSlotIsPCIExpressGen2X8(175) The system slot type is PCI Express Gen 2 x8. systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express Gen 2 x16. Table 932.
busWidthIs128bits(7) The system slot bus width is 128 bits. busWidthIs1xOrx1(8) The system slot bus width is 1x or x1. busWidthIs2xOrx2(9) The system slot bus width is 2x or x2. busWidthIs4xOrx4(10) The system slot bus width is 4x or x4. busWidthIs8xOrx8(11) The system slot bus width is 8x or x8. busWidthIs12xOrx12(12) The system slot bus width is 12x or x12. busWidthIs16xOrx16(13) The system slot bus width is 16x or x16. busWidthIs32xOrx32(14) The system slot bus width is 32x or x32.
Access Not accessible Table 937. Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Index physicalMemoryArraychassisIndex , physicalMemoryArrayIndex Table 938. Physical Memory Array Chassis Index Name physicalMemoryArraychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Description Defines the status of the physical memory array. Syntax DellStatus Access Read-only Table 943. Physical Memory Array Use Name physicalMemoryArrayUse Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.6 Description Defines the use of the physical memory array. Syntax DellPhysicalMemoryArrayUse (See Physical Memory Array ECC Type Definitions) Access Read-only Table 944. Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.
Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 949. Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.12 Description Defines the value of the physical memory array Error Checking and Correction (ECC) error nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 950.
Table 954. Physical Memory Array Mapped Table Name physicalMemoryArrayMappedTable Object ID 1.3.6.1.4.1.674.10892.1.1300.20 Description Defines the Physical Memory Array Mapped Table. Syntax PhysicalMemoryArrayMappedTableEntry Access Not accessible Table 955. Physical Memory Array Mapped Table Entry Name PhysicalMemoryArrayMappedTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1 Description Defines the Physical Memory Array Mapped Table entry.
Access Read-only Table 960. Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Table 961. Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis.
Description Defines the Physical Memory Configuration Table. Syntax SEQUENCE OF PhysicalMemoryConfigTableEntry Access Not accessible Table 966. Physical Memory Configuration Table Entry Name physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1 Description Defines the Physical Memory Configuration Table entry. Syntax PhysicalMemoryConfigTableEntry Access Not accessible Index physicalMemoryConfigChassisIndex , physicalMemoryConfigIndex Table 967.
Table 971. Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration. Syntax DellStatus Access Read-only Table 972. Physical Memory Configuration Redundant Capabilities Name physicalMemoryConfigRedundantCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.6 Description Defines the redundant capabilities of the physical memory.
Access Not accessible Table 977. Physical Memory Logging Table Entry Name physicalMemoryLoggingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1 Description Defines the Physical Memory Logging Table entry. Syntax PhysicalMemoryLoggingTableEntry Access Not accessible Index physicalMemoryLoggingChassisIndex , physicalMemoryLoggingIndex Table 978. Physical Memory Logging Chassis Index Name physicalMemoryLoggingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.
Description Defines the status of the physical memory logging. Syntax DellStatus Access Read-only Redundant Memory Unit Table This table reports the status of redundant memory within a particular system chassis. The following object sets up the Redundant Memory Unit Table: Table 983. Redundant Memory Unit Table Name redundantMemoryUnitTable Object ID 1.3.6.1.4.1.674.10892.1.1300.50 Description Defines the Redundant Memory Unit Table.
Syntax DellStateCapabilities Access Read-only Table 988. Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-only Table 989. Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1 Description Defines the Physical Memory Card Table Entry. Syntax PhysicalMemoryCardTableEntry Access Not accessible Index physicalMemoryCardChassisIndex , physicalMemoryCardIndex Table 994. Physical Memory Card Chassis Index Name physicalMemoryCardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 995.
Table 999. Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Table 1000. Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card. 2,147,483,647 indicates an unknown number of sockets.
memoryArrayUseIsCacheMemory(7) The memory array is cache memory. memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option card. memoryArrayLocationIsProprietary(9) The memory array location is a proprietary option card. memoryArrayLocationIsNUBUS(10) The memory array location is a NuBus bus. memoryArrayLocationIsPC98C20(11) The memory array location is a PC-98/C20 option card.
Table 1007. Physical Memory Configuration Redundant Capabilities Variable Name: DellPhysicalMemoryConfigRedundantCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory capabilities. unknownCapabilities(1) Redundant capabilities are unknown. The redundant capabilities are: Spare redundant memory feature is supported. spareCapable(2) mirrorCapable(4) Mirror redundant memory feature is supported.
BIOS Setup Control Group Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
Syntax DellStateCapabilities Access Read-only Table 1015. BIOS Setup Control Pointing Device Control Settings Name bSUCpointingDeviceControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.3 Description Defines the state of the pointing device. Syntax DellStateSettings Access Read-only Table 1016. BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4 Description Defines the status of the pointing device.
Table 1021. BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.9 Description Defines the setup BIOS name of the numeric lock. Syntax DellString Access Read-only Table 1022. BIOS Setup Control Processor Serial Number Control Capabilities Name bSUCprocessorSerialNumberControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.10 Description Defines if the processor serial number can be returned.
Description Defines the settings available for speaker control. Syntax DellSpeakerControlSettingsUnique (See Speaker Control Settings Unique) Access Read-only Table 1028. BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only Table 1029. BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.
Access Read-only Table 1034. BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.22 Description Defines the capabilities of the boot sequence. Syntax DellBootSequenceControlCapabilitiesUnique (See Boot Sequence Control Capabilities Unique) Access Read-only Table 1035. BIOS Setup Control Boot Sequence Control Settings Unique Name DellBootSequenceControlSettingsUnique Object ID 1.3.6.1.4.1.674.
Table 1040. BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28 Description Defines the status for administrator password control. Syntax DellStatus Access Read-only Table 1041. BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.29 Description Defines the setup BIOS name for the current administrator password.
Table 1046. BIOS Setup Control User Password Verify Name Name bSUCuserPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.34 Description Defines the setup BIOS name of the current user password. Syntax DellString Access Read-Only Table 1047. BIOS Setup Control User Password New Password Name Name bSUCuserPasswordNewPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.35 Description Defines the setup BIOS name of the new user password.
SCSI Control Table Table 1052. SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible Table 1053. SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description x Defines the SCSI Control Table entry.
Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only Table 1058. SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.5 Description Defines the status of the SCSI controller. Syntax DellStatus Access Read-only Table 1059. SCSI Control Name Name sCSIControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.6 Description Defines the setup BIOS name of the SCSI controller.
Table 1063. Parallel Port Control Index Name parallelPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.2 Description Defines the index (one-based) of the parallel port in this chassis. Syntax DellObjectRange Access Read-only Table 1064. Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3 Description Defines the capabilities of the parallel port.
Description Defines the mode settings of the parallel port. Syntax DellParallelPortControlModeSettingsUnique (See Parallel Port Control Mode Settings) Access Read-only Serial Port Control Table Table 1070. Serial Port Control Table Name serialPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.40 Description Defines the Serial Port Control Table. Syntax SerialPortControlTableEntry Access Not accessible Table 1071.
Table 1075. Serial Port Control Settings Unique Name serialPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.4 Description Defines the settings of the serial port. Syntax DellSerialPortControlSettingsUnique (See Serial Port Control Settings) Access Read-only Table 1076. Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Table 1077.
Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1081. USB Control Index Name usbControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2 Description Defines the index (one-based) of the USB in this chassis. Syntax DellObjectRange Access Read-only Table 1082. USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.
Object ID 1.3.6.1.4.1.674.10892.1.1400.60 Description Defines the IDE Control Table. Syntax IdeControlTableEntry Access Not accessible Table 1087. IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex , ideControlIndex Table 1088. IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.
Table 1092. IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only Table 1093. IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Table 1094. Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.4.1.
Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRange Access Read-only Table 1098. Diskette Control Capabilities Unique Name disketteControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.3 Description Defines the capabilities of the diskette controller. Syntax DellDisketteControlCapabilitiesUnique Access Read-only Table 1099. Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.
Description Defines the Network Interface Control Table entry. Syntax NetworkInterfaceControlTableEntry Access Not accessible Index networkInterfaceControlchassisIndex , networkInterfaceControlIndex Table 1104. Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1105.
Table 1109. Network Interface Control Name Name networkInterfaceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.6 Description Defines the setup BIOS name of the NIC. Syntax DellString Access Read-only BIOS Setting Table These MIB objects enable you to track the BIOS settings for your system. NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems. Table 1110. BIOS Setting Table Name biosSettingTable Object ID 1.3.6.1.4.1.674.10892.1.1400.
Table 1114. BIOS Setting Name Name biosSettingName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.3 Description Defines the name of the BIOS setting. Syntax DisplayString Access Read-only Table 1115. BIOS Setting Display Name Name biosSettingDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.4 Description Defines the display name of the BIOS setting. Syntax DisplayString Access Read-only Table 1116. BIOS Setting Value Type Name biosSettingValueType Object ID 1.3.6.1.4.1.674.10892.1.
Description Defines the possible values of the BIOS setting. Syntax DisplayString Access Read-only Table 1121. BIOS Setting Display Order Name biosSettingDisplayOrder Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.10 Description Defines the recommended display order of the BIOS setting within its BIOS setting group. Syntax DellUnsigned32BitRange Access Read-only Table 1122. BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.
unknown(1) Speaker control state is unknown. enabled(2) Speaker control is enabled. low(4) Speaker control volume is low. medium(8) Speaker control volume is medium. high(16) Speaker control volume is high. Table 1126. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown.
bootSequenceUnknown(1) Boot sequence state is unknown. bootFromDisketteFirst(2) Setup BIOS is set to boot by diskette first. bootFromHardDriveFirst(4) Setup BIOS is set to boot by IDE hard drive first. bootFromDeviceList(8) Setup BIOS is set to boot by a device list. bootFromCDROMFirst(16) Setup BIOS is set to boot by CD first. Table 1130.
Data Type: Integer Possible Data Values Meaning of Data Value off(0) TPM security is Off. onWithPrebootMeasurements(1) TPM security is On with Pre-boot Measurements. onWithoutPrebootMeasurements (2) TPM security is On without Pre-boot Measurements. Table 1135. Parallel Port Control Capabilities Variable Name: DellParallelPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS parallel port capabilities are unknown.
Table 1138. Serial Port Control Capabilities Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS serial port capabilities are unknown. enableCapable(2) Setup BIOS can enable the serial port. com1Capable(4) Setup BIOS can support serial port 1. enableAndCom1Capable(6) Setup BIOS can enable serial port 1. com2Capable(8) Setup BIOS can support serial port 2.
ideControlAutoConfigOrEnable Capable(2) IDE controller is autoconfigurable or enable capable. Table 1141. Diskette Control Settings Variable Name: DellDisketteControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Diskette control state is unknown. disketteControlAutoConfigEnabled OrEnabled(2) Diskette control is set as autoconfigurable or enabled. Table 1142.
LRA Group Tables The following management information base (MIB) tables define LRA variable attributes: • • LRA Global Settings Table LRA Action Table LRA Global Settings The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator. Some machines may support all or some of the capabilities described in DellLocalResponseAgentCapabilitiesUnique.
Access Read-only Table 1150. LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.4 Description Defines the set of global capabilities that all local response agents may or may not allow to be set or reset. Syntax DellLocalResponseAgentCapabilitiesUnique (LRA Capabilities Definitions) Access Read-only Table 1151. LRA Global Thermal Shutdown Capabilities Unique Name lRAGlobalThermalShutdownCapabilitiesUnique Object ID 1.3.
, lRAActionTableActionNumberIndex Table 1155. LRA Action Table Chassis Index Name lRAActionTablechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1156. LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
Table 1158. LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.4 Description Defines the LRA settings. Syntax DellLocalResponseAgentSettingsUnique (Local Response Agent Settings Unique) Access Read-only Local Response Agent Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 1159.
Data Type: Integer Possible Data Values Meaning of Data Value speakerControl(1) LRA is set to issue a speaker beep. consoleAlert(2) LRA is set to issue a console alert. broadcastMessage(4) LRA is set to issue a broadcast message. osShutDown(8) LRA is set to issue an operating system shutdown. reboot(16) LRA is set to issue a system reboot. powerCycle(32) LRA is set to issue a system power cycle. powerOFF(64) LRA is set to issue a system power off.
Access Not accessible Index coochassisIndex Table 1164. COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only Table 1165. COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.2 Description Defines the acquisition state of the system. Syntax DellStateSettings Access Read-only Table 1166.
Table 1170. COO Acquisition Purchase Date Name Name cooAquisitionPurchaseDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.7 Description Defines the purchase date and time of the system. Syntax DellDateName Access Read-only Table 1171. COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system.
Description Defines the extended warranty start date for this system. Syntax DellDateName Access Read-only Table 1177. COO Extended Warranty End Date Name Name cooExtendedWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.14 Description Defines the extended warranty end date for this system. Syntax DellDateName Access Read-only Table 1178. COO Extended Warranty Cost Name cooExtendedWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
Access Read-only Table 1183. COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-only Table 1184. COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system.
Table 1189. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-only Table 1190. COO Outsourcing Provider Service Level Name Name cooOutsourcingProviderServiceLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.27 Description Defines the service level agreement for the system.
Description Defines the name of the operating system on this system. Syntax DellCostofOwnershipString Access Read-only Table 1196. COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.33 Description Defines the name of the operating system patch level for this system. Syntax DellCostofOwnershipString Access Read-only Table 1197.
Access Read-only Table 1202. COO Registration Is Registered Name cooRegistrationIsRegistered Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.39 Description Specifies whether this system is registered or not. Syntax DellBoolean Access Read-only COO Service Contract Table The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system. Table 1203. COO Service Contract Table Name cooServiceContractTable Object ID 1.3.6.1.4.
Table 1207. COO Service Contract State Name cooServiceContractState Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3 Description Defines the status of the service contract for this system. Syntax DellStateSettings Access Read-only Table 1208. COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed. Syntax DellBoolean Access Read-only Table 1209.
Index cooCostEventLogchassisIndex , cooCostEventLogIndex Table 1213. COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1214. COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.2 Description Defines the index (one-based) of the cost event log.
Syntax DellCostofOwnershipString Access Read-only COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system. Table 1219. COO Warranty Table Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible Table 1220. COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.
Table 1224. COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty. Syntax DellUnsigned32BitRange Access Read-only Table 1225. COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.5 Description Defines the warranty duration type for the system. Syntax DellCOODayMonthDurationType Access Read-only Table 1226.
Index cooLeaseInformationchassisIndex , cooLeaseInformationIndex Table 1230. COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1231. COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system.
Syntax DellUnsigned32BitRange Access Read-only Table 1236. COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system. Syntax DellDateName Access Read-only Table 1237. COO Lease Information Fair Market Value Name cooLeaseInformationFairMarketValue Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.8 Description Defines the fair market value of this system.
Table 1241. COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1242. COO Schedule Number Index Name cooScheduleNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.2 Description Defines the index of the schedule number information. Syntax DellObjectRange Access Read-only Table 1243.
Table 1247. COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry. Syntax CooOptionsTableEntry Access Not accessible Index cooOptionschassisIndex , cooOptionsIndex Table 1248. COO Options Chassis Index Name cooOptionschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1249.
Access Read-only COO Maintenance Table Table 1253. COO Maintenance Table Name cooMaintenanceTable Object ID 1.3.6.1.4.1.674.10892.1.1600.80 Description Defines the COO Maintenance Table. Syntax SEQUENCE OF CooMaintenanceTableEntry Access Not accessible Table 1254. COO Maintenance Table Entry Name cooMaintenanceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1 Description Defines the COO Maintenance Table entry.
Table 1258. COO Maintenance Start Date Name Name cooMaintenanceStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4 Description Defines the start date for maintenance on this system. Syntax DellDateName Access Read-only Table 1259. COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-only Table 1260.
Index cooRepairchassisIndex , cooRepairIndex Table 1264. COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1265. COO Repair Index Name cooRepairIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.2 Description Defines the index (one-based) of the repair information for this system. Syntax DellObjectRange Access Read-only Table 1266.
Object ID 1.3.6.1.4.1.674.10892.1.1600.100 Description Defines the COO Support Information Table. Syntax SEQUENCE OF cooSupportInformationTableEntry Access Not accessible Table 1270. COO Support Information Table Entry Name cooSupportInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1 Description Defines the COO Support Information Table entry.
Table 1275. COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5 Description Defines the type of component, system, or network problem that occurred. Syntax DellUnsigned32BitRange Access Read-only Table 1276. COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided.
Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1281. COO Trouble Ticket Index Name cooTroubleTicketIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2 Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only Table 1282. COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.
rented(5) The ownership code is rented. offOfLease(6) The ownership code is off of lease. transfer(7) The ownership code is transfer. Table 1286. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 1287.
Description Defines the Cluster Table. Syntax SEQUENCE OF ClusterTableEntry Access Not accessible Table 1290. Cluster Table Entry Name clusterTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1 Description Defines the Cluster Table entry. Syntax ClusterTableEntry Access Not accessible Index clusterChassisIndex , clusterIndex Table 1291. Cluster Chassis Index Name clusterChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
Table 1295. Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Table 1296. Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Table 1297. Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
Baseboard Management Controller Group Tables The objects in the BMC group define information about the BMC and the serial and LAN interfaces that can be used to access the BMC remotely to perform management activities. Objects for the serial interface define the serial connection mode, flow control type and bit rate. Objects for the LAN interface define the media access control (MAC) address, internet protocol (IP) address, subnet mask and default gateway.
Table 1304. BMC State Capabilities Name bmcStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.3 Description Defines the state capabilities of the BMC. Syntax DellStateCapabilities Access Read-only Table 1305. BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-only Table 1306. BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC. Syntax Octet String Access Read-only Table 1311. BMC Type Name bmcType Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.10 Description Defines the type of the BMC. Syntax DellManagementControllerType Access Read-only Table 1312. BMC Module Name Name bmcModuleName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.11 Description Defines the module name for the BMC.
Object ID 1.3.6.1.4.1.674.10892.1.1900.20 Description Defines the BMC Serial Interface Table. Syntax SEQUENCE OF BmcSerialInterfaceTableEntry Access Not accessible Table 1317. BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1 Description Defines the BMC Serial Interface Table Entry.
Syntax DellStateCapabilities Access Read-only Table 1322. BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.5 Description Defines the state settings of the BMC serial interface. Syntax DellStateSettings Access Read-only Table 1323. BMC Serial Interface Status Name bmcSerialInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6 Description Defines the status of the BMC serial interface.
Table 1328. BMC Serial Interface Bit Rate Name bmcSerialInterfaceBitRate Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.11 Description Defines the bit rate of the BMC serial interface. Syntax DellBMCSerialBitRateType Access Read-only Baseboard Management Controller LAN Interface Table Table 1329. BMC LAN Interface Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table.
Table 1333. BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface. Syntax DellObjectRange Access Read-only Table 1334. BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.4 Description Defines the state capabilities of the BMC LAN interface. Syntax DellStateCapabilities Access Read-only Table 1335.
Description Defines the IP address of the BMC LAN interface. Syntax IpAddress Access Read-only Table 1340. BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.10 Description Defines the subnet mask of the BMC LAN interface. Syntax IpAddress Access Read-only Table 1341. BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.
modemPPP(2) BMC serial interface supports Modem Point to Point Protocol (PPP) mode. modemTerminal(4) BMC serial interface supports Modem Terminal mode. directBasic(8) BMC serial interface supports Direct Basic mode. directPPP(16) BMC serial interface supports Direct PPP mode. directTerminal(32) BMC serial interface supports Direct Terminal mode. Table 1345.
Table 1348. BMC LAN IP Address Source Type Variable Name:DellBMCLANIPAddressSourceType Data Type:Integer Possible Data Values Meaning of Data Value -- unspecified(0) Source is unspecified. static(1) IP address is static. dhcp(2) Dynamic Host Configuration Protocol (DHCP) used to obtain IP address. biosOrSystemSoftware(3) BIOS or system software provided IP Address. other(4) Other protocol used to obtain IP address. Table 1349.
formFactorTypeIsSingleWidthFull Form Factor Type is SingleWidthFullHeight. Height(3) formFactorTypeIsDualWidthFullHe Form Factor Type is DualWidthFullHeight. ight(4) formFactorTypeIsSingleWidthQuar Form Factor Type is terHeight(5) SingleWidthQuarterHeight. Form Factor Type is 1UHalfWidth. formFactorTypeIs1UHalfWidth(6) formFactorTypeIs1UQuarterWidth( Form Factor Type is 1UQuarterWidth. 7) formFactorTypeIs1UFullWidth(8) Form Factor Type is 1UFullWidth.
Access Read-only Table 1354. FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only Table 1355. FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.3 Description Defines the status of the FRU table entry. Syntax DellStatus Access Read-only Table 1356. FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.
Table 1360. FRU Part Number Name Name fruPartNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8 Description Defines the part number of the FRU Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1361. FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1362. FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.
3 Storage Management Group The Storage Management Group is composed of the following: • • • • • • Storage Management Group—information about the software product and system status. Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. Global Data Group—system status. Physical Devices Group—physical devices managed by the software. Logical Devices Group—logical devices managed by the software. Storage Management Event Group—SNMP traps.
Access Read-only Table 1367. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Table 1368. Software Product Name softwareProduct Object ID 1.3.6.1.4.1.674.10893.1.20.4 Description Identifies product information for the Storage Management software. Syntax DisplayString Access Read-only Table 1369.
Syntax DisplayString Access Read-only Table 1373. Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion. Syntax DisplayString Access Read-only Global Data Group The Global Data Management Information Base (MIB) Group defines the properties that identify status information about the system that the Storage Management software is managing and about the Storage Management SNMP agent. Table 1374.
Table 1378. Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When set, the modifier is active. Bit definitions: Bit 3: agent in debug mode. All other bits are product specific. Syntax Integer Access Read-only Table 1379. Agent Refresh Rate Name agentRefreshRate Object ID 1.3.6.1.4.1.674.10893.1.20.110.6 Description Identifies the rate, given in seconds, at which the cached data for SNMP is refreshed.
Table 1384. Agent MIB Version Name agentMibVersion Object ID 1.3.6.1.4.1.674.10893.1.20.110.11 Description Identifies the version of the Storage Management MIB. Syntax DisplayString Access Read-only Table 1385. Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Table 1386.
Access Read-only Table 1388. Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.15 Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures.
Description Defines the controller table, which is a table of managed Redundant Array of Independent disks (RAID) controllers. The number of entries is related to the number of RAID controllers discovered in the system. Syntax SEQUENCE OF ControllerEntry Access Not accessible Table 1390. Controller Entry Name controllerEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1 Description Defines the controller table entry, which is an entry in the table of RAID controllers.
6: Serial Attached SCSI (SAS) 9: PCIe SSD Syntax Integer Access Read-only Table 1395. Controller State Name controllerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.5 Description Identifies the status of the controller's subsystem (which includes any devices connected to it). Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Table 1396. Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Description Identifies the controller's current amount of cache memory in megabytes. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Table 1399. Controller Cache Size in Bytes Name controllerCacheSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.10 Description Identifies the controller's current amount of cache memory that is less than a megabyte. This combined with the controllerCacheSizeInMB is the total amount of memory.
Description Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Table 1405. Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte.
Syntax Integer Access Read-only Table 1411. Controller C0 Target Name controllerC0Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1412. Controller C0 Channel Name controllerC0Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.23 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Table 1417. Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1418. Controller C1 Target Name controllerC1Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1419.
Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1424. Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.35 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1425. Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.
6: Non-recoverable Syntax DellStatus Access Read-only Table 1428. Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Table 1429. Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates state, or setting for the controller's alarm.
99: Not Applicable Syntax Integer Access Read-only Table 1433. Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller. Syntax DisplayString Access Read-only Table 1434. Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Access Read-only Table 1439. Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.50 Description The rate for background initialization on the controller. Syntax Integer Access Read-only Table 1440. Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51 Description The rate for check consistency on the controller. Syntax Integer Access Read-only Table 1441.
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55 Description Provides current Windows OS storport driver version. Not applicable for Linux. Syntax Octet String Access Read-only Table 1445. Controller Minimum Required Storport Version Name controllerMinimumRequiredStorportVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56 Description Provides minimum required storport driver version for Windows OS only. Syntax Octet String Access Read-only Table 1446.
Description Indicates controller capability to put hot spare drives in power save mode. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined /Not applicable Syntax Integer Access Read-only Table 1450. Controller Spin Down Time Interval Name controllerSpinDownTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62 Description Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode.
Table 1455. Controller Configured Drives SpinUp Time Name controllerConfiguredDrivesSpinUpTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.67 Description Indicates configured drives spin up start time. Value: 1:00 AM to 12:59 PM, 9999 Undetermined Syntax DisplayString Access Read-only Table 1456. Controller Configured Drives SpinUp TimeInterval Name controllerConfiguredDrivesSpinUpTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Channel Table This table describes available properties for each channel on the managed system. The following object sets up the Channel Table. Table 1460. Channel Table Name channelTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.2 Description Defines the channel table. Syntax SEQUENCE OF ChannelEntry Access Not accessible Table 1461. Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry.
6: Degraded Syntax Integer Access Read-only Table 1465. Channel Severity Name channelSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1466. Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel.
Access Read-only Table 1469. Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1470. Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Access Read-only Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Table 1473. Enclosure Table Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Table 1474. Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1 Description Defines the enclosure table entry.
Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.4 Description The current condition of the enclosure (which includes any devices connected to it.) Possible values: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Table 1479. Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
Description Customer definable asset tag for the enclosure. Syntax DisplayString Access Read-only Table 1484. Enclosure Asset Name Name enclosureAssetName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 Description Customer definable asset name of the enclosure. Syntax DisplayString Access Read-only Table 1485. Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11 Description Identifies the enclosure's split bus part number.
Access Read-only Table 1490. Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure. Possible values: 1: Internal 2: Dell PowerVault 200S (PowerVault 201S) 3: Dell PowerVault 210S (PowerVault 211S) 4: Dell PowerVault 220S (PowerVault 221S) 5: Dell PowerVault 660F 6: Dell PowerVault 224F 7: Dell PowerVault 660F/PowerVault 224F 8: Dell MD1000 9: Dell MD1120 Syntax DisplayString Access Read-only Table 1491.
Table 1494. Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 Description Identifies the current status of the enclosure's alarm (PowerVault 220S and PowerVault 221S only.) Possible values: 1: Disabled 2: Enabled Syntax Integer Access Read-only Table 1495. Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane.
Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1499. Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.25 Description Durable unique ID for this enclosure. Syntax Integer Access Read-only Table 1500. Enclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.26 Description The firmware version of the enclosure.
Table 1504. Enclosure SAS Address Name enclosureSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.30 Description The specified SAS address if this is a SAS enclosure. Syntax DisplayString Access Read-only Table 1505. Enclosure Occupied Slot Count Name enclosureOccupiedSlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.31 Description Shows the number of physical disk slots occupied in a storage enclosure. NOTE: A value of 9999 indicates that the feature is not available.
Table 1509. Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1 Description Defines the array disk table entry. Syntax ArrayDiskEntry Access Not accessible Index arrayDiskNumber Table 1510. Array Disk Number Name arrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.1 Description Identifies the instance number of the array disk entry. Syntax Integer Access Read-only Table 1511. Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.
15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 22: Replacing - Indicates copyback operation is in progress. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 34: Predictive Failure 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.
Access Read-only Table 1518. Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Table 1519. Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected. Syntax Integer Access Read-only Table 1520.
Access Read-only Table 1524. Array Disk Target ID Name arrayDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.15 Description Identifies the SCSI target ID which this array disk is assigned. Syntax Integer Access Read-only Table 1525. Array Disk LUN ID Name arrayDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.16 Description Identifies the array disk's logical unit number. Syntax Integer Access Read-only Table 1526.
Syntax Integer Access Read-only Table 1530. Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.21 Description Identifies the bus type of the array disk. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: SSA 6: USB 7: SATA 8: SAS 9: PCIe Syntax Integer Access Read-only Table 1531. Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare.
6: Non-recoverable Syntax DellStatus Access Read-only Table 1533. Array Disk Component Status Name arrayDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.24 Description The status of the array disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1534. Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.
Access Read-only Table 1538. Array Disk Negotiated Speed Name arrayDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.29 Description Indicates the speed at which the drive is actually running in MPS (megabytes per second). Syntax Integer Access Read-only Table 1539. Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Description Indicates the four digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Table 1544. Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description The Media type of the array disk. Possible Values: 1:unknown 2:hdd 3:ssd Syntax INTEGER Access Read-only Table 1545. Array Disk Dell Certified Name arrayDiskDellCertified Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Table 1549. Array Disk Encryption Capable Name arrayDiskEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.40 Description Indicates if physical disk is encryption capable. Value: 1 - Capable, 0 - Not Capable, 99 - Not Applicable Syntax Integer Access Read-only Table 1550. Array Disk Encrypted Name arrayDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.41 Description Indicates if the physical disk has encryption enabled.
Table 1555. Array Disk Driver Version Name arrayDiskDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.46 Description Provides PCIe SSD device driver version. Syntax INTEGER Access Read-only Table 1556. Array Disk Device Life Status Name arrayDiskDeviceLifeStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.47 Description Provides PCIe SSD device life status.
Possible Values: 512 or 4096 Syntax INTEGER Access Read-only Table 1560. Array Disk PI Capable Name arrayDiskPICapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.51 Description Provides the information regarding T10 PI capability of array disk. Possible Values: 0 : T10 PI incapable or 1 : T10 PI capable Syntax INTEGER Access Read-only Table 1561. Array Disk Max Link Width Name arrayDiskMaxLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.55 Description Displays the current disk write cache policy of the array disk. Possible Values: Enabled - Disabled - Default Syntax DisplayString Access Read-only Array Disk Enclosure Connection Table This table describes the connections among array disks, their enclosure, and their associated controller.
Table 1569. Array Disk Enclosure Connection Array Disk Number Name arrayDiskEnclosureConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection. Syntax Integer Access Read-only Table 1570. Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
Table 1574. Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Table 1575. Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1 Description Defines the array disk channel connection table entry.
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.4 Description Identifies the name of the channel as represented in Storage Management to which is array disk is connected. Syntax DisplayString Access Read-only Table 1580. Array Disk Channel Connection Channel Number Name arrayDiskChannelConnectionChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.5 Description Identifies the instance number of the channel in the channelTable to which this array disk is connected.
Table 1584. Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Table 1585. Fan Number Name fanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1 Description Identifies the instance number of the fan entry. Syntax Integer Access Read-only Table 1586. Fan Name Name fanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
Table 1589. Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1590. Fan Probe Unit Name fanProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.6 Description This entry is obsolete for Storage Services. Syntax DisplayString Access Read-only Table 1591.
Table 1595. Fan Probe Current Value Name fanProbeCurrValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 Description Identifies the current speed of the fan. Syntax DisplayString Access Read-only Table 1596. Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Table 1597. Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.
4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1600. Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Table 1601. Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure.
Syntax Integer Access Read-only Table 1605. Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 Description Identifies the name of the fan in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1606. Fan Connection Fan Number Name fanConnectionFanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.3 Description Identifies the instance number of the fan in the fanTable in the connection.
Syntax PowerSupplyTableEntry Access Not accessible Index powerSupplychassisIndex, powerSupplyIndex Table 1611. Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1612. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply.
Access Read-only Table 1617. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (Power Supply Type Definitions) Access Read-only Table 1618. Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.8 Description Defines the location name of the power supply. Syntax DellString Access Read-only Table 1619.
Table 1623. Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.13 Description Defines a boolean value that reports whether the power supply is capable of monitoring power consumption. Syntax DellBoolean Access Read-only Table 1624. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.
Description Defines the power supply connection table entry. Syntax PowerSupplyConnectionEntry Access Not accessible Index powerSupplyConnectionNumber Table 1629. Power Supply Connection Number Name powerSupplyConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.1 Description Identifies the instance number of the power supply connection entry. Syntax Integer Access Read-only Table 1630.
Description Displays power supply connection firmware version. NOTE: Available above 1.04 firmware version. Syntax DisplayString Access Read-only Temperature Probe Table Table 1635. Temperature Probe Table Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10892.1.700.20 Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Table 1636. Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.
Description Defines the capabilities of the temperature probe. Syntax DellStateCapabilities Access Read-only Table 1640. Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-only Table 1641. Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.9 Description Defines the value of the temperature probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 1646. Temperature Probe Upper Critical Threshold Name temperatureProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.10 Description Defines the value of the temperature probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Table 1647.
Syntax DellProbeCapabilities Access Read-only Table 1652. Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.16 Description Defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, a value is not returned for this attribute.
Description Identifies the name of the temperature probe in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1657. Temperature Probe Connection Temperature Probe Number Name temperatureConnectionTemperatureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.3 Description Identifies the instance number in the temperatureTable of the temperature probe in this connection. Syntax Integer Access Read-only Table 1658.
Access Not accessible Index enclosureManagementModuleNumber Table 1662. Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 Description Identifies the instance number of the enclosure management module entry. Syntax Integer Access Read-only Table 1663. Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1667. Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6 Description Identifies the part number of the enclosure memory module. Syntax Display String Access Read-only Table 1668.
3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1672. Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.11 Description The status of the enclosure management module itself without the propagation of any contained component status.
Description Defines the enclosure memory module connection table. Syntax SEQUENCE OF EnclosureManagementModuleConnectionEntry Access Not accessible Table 1676. Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry.
Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs. Syntax Integer Access Read-only Battery Table Table 1682. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 1683. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.
Table 1687. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-only Table 1688. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Table 1689. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.
Syntax BatteryConnectionEntry Access BatteryConnectionEntry Index BatteryConnectionNumber Table 1693. Battery Connection Number Name batteryConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.1 Description Identifies the instance number of the battery connection entry. Syntax Integer Access Read-only Table 1694. Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
Table 1698. Tape Drive Table Name tapeDriveTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.17 Description A table of listed Tape Drives The number of entries is related to number of Tape Drives discovered in the system. The maximum number of entries is implementation dependent. NOTE: The properties in this table may not be applicable to all entries. Syntax SEQUENCE OF TapeDriveEntry Access Not accessible Table 1699. Tape Drive Entry Name tapeDriveEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.
Table 1704. Tape Drive Nexus ID Name tapeDriveNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.5 Description Durable unique ID for this tape drive Syntax DisplayString Access Read-only Table 1705. Tape Drive Bus Type Name tapeDriveBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.6 Description The bus type of the tape drive. Possible values: 8. SAS Syntax INTEGER Access Read-only Table 1706. Tape Drive SAS Address Name tapeDriveSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.
Table 1709. NVME Adapter Entry Name nvmeAdapterEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1 Description An entry in the NvmeAdapter table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax NvmeAdapterEntry Access Not accessible Table 1710. NVME Adapter Number Name nvmeAdapterNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.1 Description Instance number of this NVME Adapter entry. Syntax INTEGER Access Read-only Table 1711.
Table 1715. NVME Adapter Vendor Name nvmeAdapterVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.6 Description NVMe Adapter manufacturer. Syntax DisplayString Access Read-only Table 1716. NVME Adapter Product ID Name nvmeAdapterProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.7 Description The product id or part number of the NVMe Adapter. Syntax DisplayString Access Read-only Table 1717. NVME Adapter Serial Number Name nvmeAdapterSerialNumber Object ID 1.3.6.1.4.1.674.
Description The PCI device number of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1722. NVME Adapter PCI Func Number Name nvmeAdapterPCIFuncNum Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.13 Description The PCI device number of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1723. NVME Adapter Nexus ID Name nvmeAdapterNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.14 Description Nexus ID of the NVMe Adapter.
Table 1727. NVME Adapter Length Offset Bytes Name nvmeAdapterLengthOffsetBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.18 Description Number of bytes after total number of megabytes have been subtracted from the total size of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1728. NVME Adapter Device ID Name nvmeAdapterDeviceID Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.19 Description The device Id of the NVMe Adapter. Syntax INTEGER Access Read-only Table 1729.
Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.24 Description The form factor of the NVMe Adapter. Possible Values 2 : Card Syntax INTEGER Access Read-only Table 1734. NVME Adapter Supported Specification Name nvmeAdapterSupportedSpec Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.25 Description The NVMe specification supported by the device. Syntax DisplayString Access Read-only Table 1735. NVME Adapter Maximum Link Width Name nvmeAdapterMaxLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.
Virtual Disk Table This table describes available properties for each virtual disk on the managed system. The following object sets up the Virtual Disk Table. Table 1738. Virtual Disk Table Name virtualDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1 Description Defines the virtual disk table. Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible Table 1739. Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.
Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 3: Online 4: Offline - The disk is not accessible. The disk may be corrupted or intermittently unavailable. 6: Degraded - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online.
Table 1747. Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.8 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1748. Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete.
Table 1751. Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable Syntax INTEGER Access Read-only Table 1752. Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type.
Access Read-only Table 1757. Virtual Disk LUN ID Name virtualDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1758. Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Severity of the virtual disk state.
Access Read-only Table 1761. Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk. Possible values: 1: SAS 2: SATA 3: SCSI 4: IDE 99: Unknown Syntax INTEGER Access Read-only Table 1762. Virtual Disk Bad Blocks Detected Name virtualDiskBadBlocksDetected Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
SWRAID : 2 - Enabled, 4 - Disabled, 8 - Default, 10 - Undetermined Syntax INTEGER Access Read-only Table 1766. Virtual Disk PI Enable Name virtualDiskPIEnable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.28 Description Indicates if T10 PI is enabled on a virtual disk. Possible values are: 0 : T10 PI disabled, 1 : T10 PI enabled Syntax INTEGER Access Read-only Virtual Disk Partition Table 1767. Virtual Disk Partition Table Name virtualDiskPartitionTable Object ID 1.3.6.1.4.1.674.10893.1.20.
Syntax OCTET STRING Access Read-only Table 1771. Virtual Disk Partition State Name virtualDiskPartitionState Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.3 Description State of the partition. This is mapped stated of the associate virtual disk. • • • • Active - Mapped cache disk is working fine. No - Fluid cache is not enabled. Removing - This is a transient stage during the process of disabling the cache. Failed - Mapped cache disk has failed. Syntax INTEGER Access Read-only Table 1772.
Description Defines the array disk logical connection table entry. Syntax ArrayDiskLogicalConnectionEntry Access Not accessible Index arrayDiskLogicalConnectionNumber Table 1776. Array Disk Logical Connection Number Name arrayDiskLogicalConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.1 Description Identifies the instance number of the disk entry. Syntax Integer Access Read-only Table 1777.
Syntax DisplayString Access Read-only Table 1782. Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 Description Identifies the instance number of the disk group to which this array disk belongs. This property is currently not supported. Syntax Integer Access Read-only Storage Management Event Group The Storage Management Event Group defines the properties that are sent with SNMP traps. Table 1783.
Description MIB OID of the object causing the alert. Syntax DisplayString Access Read-only Table 1788. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1789. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable.
4 Change Management Group The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. NOTE: On systems running Linux, the optional srvadmin-cm RPM package must be installed for Dell OpenManage Server Administrator to respond to SNMP queries in this group. See the Server Administrator Installation Guide for more information.
Device Group Table The following object sets up the Device Group Table. Table 1794. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1795. Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.1 Description Defines a device entry. Syntax DeviceEntry Access Not accessible Table 1796. Device Index Name deviceIndex Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Table 1800. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device. Syntax Octet String Access Read-only Table 1801. Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Table 1802. Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.7 Description Provides additional vendor identification.
Table 1805. Application Index Name aplicationIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.1 Description Defines the unique index for this application. Syntax Unsigned16BitRange Access Read-only Table 1806. Application Device Index Name applicationDeviceIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.2 Description Defines a cross-index to the device table for the application. Syntax Unsigned16BitRange Access Read-only Table 1807.
Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Inventory Collector Product Information The following objects describe the fields for the Inventory Collector.
5 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Table 1813. Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.3 Description Describes the alert. Syntax DisplayString Table 1814.
Object ID 1.3.6.1.4.1.674.10892.4.5000.10.9 Description Specifies the system service tag of the system generating the alert. Syntax DisplayString Table 1820. Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.4.5000.10.10 Description Specifies the chassis service tag of the system generating the alert. Syntax DisplayString Understanding The Trap Description The below table lists in alphabetical order each line item that may appear in the trap description.
Description Line Item Explanation Device location: Specifies the location of the device in the specified chassis, for example: Discrete current state: Specifies the state of the current sensor, for example: Discrete temperature state: Specifies the state of the temperature sensor, for example: Discrete voltage state: Specifies the state of the voltage sensor, for example: Fan sensor value: Specifies the fan speed in revolutions per minute (R
Description Line Item Explanation SD card device type: Specifies the type of SD card device, for example: SD card state: Specifies the state of the SD card, for example: Sensor location: Specifies the location of the sensor in the specified chassis, for example: Temperature sensor value (in degrees Celsius): Specifies the temperature in degrees Celsius, for example: Voltage sensor value (in Volts): Specifies the
TrapID Description Severity 65801 Over-Temperature Problem (Upper Critical - going high) Critical 65929 Over-Temperature Problem Cleared Information 131328 Under-Voltage Warning (Lower Non Critical Warning - going low) 131456 Under-Voltage Warning Cleared Information 131330 Under-Voltage Problem (Lower Critical going low) Critical 131458 Under-Voltage Problem Cleared Information 131335 Over-Voltage Warning (Upper Non Critical - Warning going high) 131463 Over-Voltage Warning Cleared
TrapID Description Severity 487298 CPU BIST (Built In Self Test) Failure Cleared Information 487176 CPU Disabled (Processor Disabled) Critical 487304 CPU Enabled (Processor Enabled) Information 487178 CPU Throttle (Processor Speed Reduced) Warning 487306 CPU Throttle Cleared (Normal Processor Speed) Information 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy has returned to Normal Information 552704 Power
6 Storage Management Alert Reference Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Topics: • • • • • • Alert Monitoring and Logging Viewing Alerts Alert Severity Levels SNMP Support for Storage Management Alerts Viewing SNMP Traps Alert Descriptions and Corrective Actions Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging.
Warning/Non-critical A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional. For example, a Warning/Non-critical alert may indicate that a component (such as a temperature probe in an enclosure) has crossed a warning threshold. Critical/Failure/Error A component has either failed or failure is imminent. This alert indicates a serious problem such as data loss or a loss of function.
Syntax DisplayString Access Read-only Table 1825. Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Table 1826. Object Name Event Name objectNameEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.4 Description Name of the object as represented in Storage Management causing the alert. Syntax DisplayString Access Read-only Table 1827.
The below table shows the new enhanced mode varbinds which would be available in the EEMI were the user can get both Traditional and Enhanced varbinds : Table 1831. Enhanced Message ID Event Name enhancedMessageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.9 Description Enhanced Message ID of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1832. Enhanced System FQDN Event Name systemFQDNEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
7 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 1837. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled. unknown(1) The object’s state is unknown.
other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant. degraded(4) The object’s redundancy has been degraded. lost(5) The object’s redundancy has been lost. notRedundant(6) Redundancy does not apply or it is not redundant. Table 1841.
8 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.43.1 = '\03' 1.3.6.1.4.1.674.10892.1.300.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.2.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.300.10.1.5.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.6.1 = 23 1.3.6.1.4.1.674.10892.1.300.10.1.7.1 = 'Main System Chassis' 1.3.6.1.4.1.674.10892.1.300.10.1.8.1 = 'Dell Inc.' 1.3.6.1.4.1.674.10892.