Server Administrator 8.3.
1 Server Administrator 8.3.0 Release Notes This document describes the new features, enhancements, and fixed issues in Server Administrator 8.3.0. Release Type and Definition Server Administrator This document contains updated information for the Server Administrator User's Guide and any other technical documentation included with Server Administrator.
Software Requirements • • • • • • Supported operating system and web browser. TCP/IP connection on the managed system and the remote system to facilitate remote system management. Supported systems management protocol standard. For more information, see Supported Systems Management Protocol Standards. The Server Administrator Remote Access Controller service requires remote access controller (RAC) to be installed on the managed system.
• • • • • • • • • • • • • • • • • BITS194072: EEMI message format selecting "No" will give EEMI message-format option again BITS192754: ESTGR: Execute Disable (XD) capability value is displayed wrongly in OMSA GUI BITS216267: OMSA 8.
Notes for Storage Management Service Detailed information on the Storage Management Service is available in the Storage Management Service online help. After installing and launching Server Administrator, you can access the Storage Management Service online help by selecting the Storage or lower-level tree object and clicking the Help button on the global navigation bar. Notes for Remote Access Service • • • The remote access service is available on supported systems only in this release.
Issues of Server Administrator on all Linux Operating Systems • • DF275424 and DF332775: Domain users unable to login to Windows MN from Linux Web Server. ○ Negotiate authentication is not supported while remotely managing a Windows-based managed node from a Linux-based Server Administrator Web server. If you run the Server Administrator Web server on a Linux based operating system and try to manage a remote Windows managed system as a domain user, a login failed message is displayed.
• • The DSM Server Administrator Connection Service may hang on system startup if both Oracle and VERITAS Backup Exec are installed on the system. To manually start the DSM Server Administrator Connection Service on a system running Windows, click Start > Programs > Administrative Tools > Service, right-click DSM Server Administrator Connections Services and select Start.
• Start > Settings > Control panel > Add Remove Programs > Select Change on the Server Administrator installation and select the Repair option to correct the issue. DF330800: Server Administrator Web server local user login fails on the Windows 2008 R2 Managed Node. When a Windows 2008 R2 Managed Node is added to a domain, logging in from any Server Administrator Web Server to that Windows 2008 R2 Managed Node will fail with local user or local power-user credentials.
• • • • • • • • • • • • • • 1. Type: omconfig system webserver action=stop 2. Locate the keystore.db.bak file. The default path is C:\program files\dell\SysMgt\apache-tomcat\conf. 3. Copy keystore.db.bak to keystore.dbkeystore.db. 4. Type: omconfig system webserver action=start A temperature drop below a minimum failure threshold does not cause a system reset even if this alert action is set.
• • • The selection of default option for the front panel LCD in Server Administrator displays the Model Name whereas the default is a Service Tag on the physical LCD. If Server Administrator does not respond or is locked to your selections on the component tree, perform the following steps: 1. Click Preferences. The Preferences page appears. 2. Click Server Administrator. The items on the front page may respond to your click.
- • • • • • • • Rename the keystore.db.bak at /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to keystore.db 3. Start the Web server. BITS078118: On 12th generation of PowerEdge servers with specific versions of iDRAC, you cannot set the platform event alert actions (reboot, shut down, and so on) through Server Administrator. Set the alert actions for the events through iDRAC GUI.
• • The RAC may not send traps when your system is locked up. To enable traps to be sent when the system is locked, configure the watchdog timer using the Server Administrator GUI. On the GUI, click the "Properties" tab and ensure that Auto Recovery is selected. The default value of theAction On Hung Operating System Detection setting is None.None indicates that detection will not be performed. RAC firmware 2.
Type: Direct-Access • • ANSI SCSI revision: 02 DF531509: The setup and/or system password configuration from the Server Administrator GUI or CLI is successful, but the password is displayed as blank instead of asterisk (*) on the F2 BIOS page. DF532055: From Windows Server 2008 R2 SP1, when an administrator manages Red Hat Enterprise Linux 6.1 (64-bit) or 5.7 (32 and 64-bit) operating systems, Server Administrator reports connection error intermittently.
• Hot plug of enclosures takes time to enumerate the enclosure and its components. During this time, there will be a delay in the response time of tasks, such as displaying the physical disks on the physical disk page and in the virtual disk selection page. • All virtual disks from the SAS/iR controller display the name IR Virtual Disk on the Preview page. On successful import, another name is assigned to these virtual disks and the "IR Virtual Disk" name is not displayed on the "Preview" page.
• BITS128355: The slot occupancy report displays single backplane ID and backplane name in the Storage Management GUI and CLI. The physical disk slot occupancy report for PCIe Subsystem displays NVMe devices present in two different PCIe backplanes under the same PCIe backplane on PowerEdge R920 servers. The NVMe devices connected to different PCIe backplanes are displayed correctly under Storage > PCIe-SSD Subsystem > PCIe-SSD Extender > Enclosure.
you must restart the server after using the Auto Configure RAID0 operation to ensure that all the physical disks in Ready state are created with RAID 0 volumes. • BITS268181: When a user creates a virtual disk using the GUI, physical disks are not listed under Dedicated Hot spare (DHS). So, the user will not be able to assign DHS while creating a virtual disk. Workaround: After creating the virtual disk, the user can assign DHS using the Assign/Unassign Dedicated Hot spare virtual disk operation.
• • • • • • 10. Click OK and restart your browser. If you run a security scanner tool such as Nessus, against the Server Administrator Web server, security warnings may be displayed against port 1311, the port running the Server Administrator Web server. The warnings have been investigated by engineering and are determined to be "false positives" (invalid security warnings) that you can ignore.
Table 1. Firmware for PERC controllers (continued) SAS 6/iR Integrated 00.25.47.00 06.22.03.00 SAS 6/iR Adapter 00.25.47.00 06.22.03.00 SAS 6/int. Modular 00.25.47.00 06.22.03.00 PERC H800 Adapter 12.10.5-0001 PERC H700 Integrated 12.10.5-0001 PERC H700 Adapter 12.10.5-0001 PERC H700 Modular 12.10.5-0001 PERC H200 Adapter 07.03.06.00 PERC H200 Integrated 07.03.06.00 PERC H200 Modular 07.03.06.00 PERC H200 Embedded 07.03.06.00 6Gbps SAS HBA 07.03.06.00 Internal Tape Adapter 07.03.06.
Table 1. Firmware for PERC controllers (continued) PERC H730P Adapter 25.4.0.0011 PERC H730P Mini Blades 25.4.0.0011 PERC H730P Mini 25.4.0.0011 PERC H730P Slim 25.4.0.0011 PERC H730 Adapter 25.4.0.0011 PERC H730 Mini 25.2.1.0011 Blades 25.4.0.0011 PERC H730 Mini 25.4.0.0011 PERC H830 Adapter 25.4.0.0011 PERC H330 Adapter 25.4.0.0011 PERC H330 Mini 25.4.0.0011 PERC H330 Mini Blades 25.4.0.0011 PERC H330 Embedded 25.4.0.0011 FD33XD-PERC Dual 25.4.0.0011 FD33XS-PERC Single 25.4.0.
Table 2. Microsoft Windows drivers for PERC controllers(continued) LSI 1020 on a PowerEdge 1600SC Not Applicable Not Applicable LSI 1030 on a PowerEdge 1750 Not Applicable Not Applicable PERC H800 Adapter 4.31.1.32 4.31.1.64 PERC H700 Integrated 4.31.1.32 4.31.1.64 PERC H700 Adapter 4.31.1.32 4.31.1.64 PERC H700 Modular 4.31.1.32 4.31.1.64 PERC H200 Adapter 2.0.35.10 2.0.35.10 PERC H200 Integrated 2.0.35.10 2.0.35.10 PERC H200 Modular 2.0.35.10 2.0.35.10 6Gbps SAS HBA 2.0.35.
Table 2. Microsoft Windows drivers for PERC controllers(continued) PERC H730P Slim 6.603.01.00 6.603.01.00 PERC H730 Adapter 6.603.01.00 6.603.01.00 PERC H730 Mini Blades 6.603.01.00 6.603.01.00 PERC H730 Mini 6.603.01.00 6.603.01.00 PERC H830 Adapter 6.603.01.00 6.603.01.00 PERC H330Adapter 6.603.01.00 6.603.01.00 PERC H330 Mini 6.603.01.00 6.603.01.00 PERC H330 Mini Blades 6.603.01.00 6.603.01.00 PERC H330 Embedded 6.603.01.00 6.603.01.00 FD33XD- PERC Dual 6.603.01.00 6.603.
Table 3. Linux Drivers for PERC Controllers (continued) Integrated SAS 6/iR Native Native Not Applicable SAS 6/int.
Table 3.