Dell OpenManage SNMP Reference Guide for iDRAC and Chassis Management Controller
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2016 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction........................................................................................................... 5 What’s new in this release..................................................................................................................... 5 Supported SNMP Versions.................................................................................................................... 5 Managed Object Used in This Document.......................................................
Blade Servers................................................................................................................................. 53 Rack and Tower Servers................................................................................................................53 iDRAC Supported SNMP Versions...................................................................................................... 53 iDRAC SNMP Data Security Features.............................................................
1 Introduction This reference guide provides information about Simple Network Management Protocol (SNMP) Management Information Base (MIB) which are released with the current version of Dell iDRAC and Chassis Management Controller. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this guide.
MIB Name Agent / Hardware Supported Purpose of the MIB instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.mib Server Administrator Provides the information about the system Field Replaceable Unit (FRU) to SNMP management applications. dcstorag.mib Server Administrator Storage Management Provides the information about the storage hardware components and RAID configurations monitored by Server Administrator. iDRAC-SMIv1.
where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1.
Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at dell.com/ support/manuals.
These objects comprise the Server Administrator definitions for the UUID. Table 3. UUID Table Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Table 4. UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex , uUIDchassisIndex Table 5.
Syntax DellUUIDType Access Read-only Table 8. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE[16]) Access Read-only Read-only Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at dell.com/support/manuals. On the Manuals page, click Software Systems Management.
Chassis Management Controller Group 2 Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB attributes provide product information for the chassis management controller: Table 9. DRsProductName Name drsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Description Defines the product manufacturer of a chassis management controller. Syntax DellString Access Read-only Table 13. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 14. DRsChassisServiceTag Name drsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis.
Table 18. DRsProductChassisName Name drsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Table 19. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 20. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Description Defines the data center locator of the chassis. Syntax DellString Access Read-only Table 24. DRsProductChassisAisle Name drsProductChassisAisle Object ID 1.3.6.1.4.1.674.10892.2.1.1.16 Description Defines the aisle locator of the chassis. Syntax DellString Access Read-only Table 25. DRsProductChassisRack Name drsProductChassisRack Object ID 1.3.6.1.4.1.674.10892.2.1.1.17 Description Defines the rack locator of the chassis. Syntax DellString Access Read-only Table 26.
Table 29. DRsProductChassisSystemID Name drsProductChassisSystemID Object ID 1.3.6.1.4.1.674.10892.2.1.1.21 Description Defines the system ID of the chassis. Syntax INTEGER Access Read-only Table 30. DRsProductChassisSize Name drsProductChassisSize Object ID 1.3.6.1.4.1.674.10892.2.1.1.22 Description Defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component. Syntax INTEGER Access Read-only Table 31.
Chassis Status The following MIB attributes provide status information on the chassis being monitored by the chassis management controller. Table 34. DRsGlobalSystemStatus Name drsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 35. DRsGlobalCurrStatus Name drsGlobalCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.
Description Defines the redundancy status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 39. DRsPowerCurrStatus Name drsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 40. DRsFanCurrStatus Name drsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.
Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 44. DRsChassisFrontPanelAmbientTemperature Name drsChassisFrontPanelAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.10 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. Syntax DellTemperatureReading Access Read-only Table 45.
Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 49. DRsKVMPrevStatus Name drsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 50. DRsRedPrevStatus Name drsRedPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.
Description Defines the previous blade subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 54. DRsTempPrevStatus Name drsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 55. DRsCMCPrevStatus Name drsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.
Syntax TimeTicks Access Read-only Table 59. DRsRedChangeTime Name drsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only Table 60. DRsPowerChangeTime Name drsPowerChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.5 Description Defines the timestamp of the most recent power health status change. Syntax TimeTicks Access Read-only Table 61.
Table 64. DRsCMCChangeTime Name drsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change. Syntax TimeTicks Access Read-only Chassis Power The following MIB tables provide power information for the chassis being monitored by the chassis management controller. Table 65. DRsCMC Power Table Name drsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table.
CMC Power Information The following MIB tables provide information on the chassis power. Table 69. DRsChassisIndex Name drsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only Table 70. DRsPotentialPower Name drsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
Syntax DellPowerReading Access Read-only Table 74. DRsKWhCumulative Name drsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only Table 75. DRsKWhCumulativeTime Name drsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset.
Table 79. DRsWattsMinTime Name drsWattsMinTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11 Description Defines the time stamp of the most recent chassis minimum power usage. Syntax DellPowerReading Access Read-only Table 80. DRsWattsResetTime Name drsWattsResetTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12 Description Defines the time stamp of the most recent reset of the chassis minimum/maximum watts readings. Syntax DellTimestamp Access Read-only Table 81.
Access Read-only Table 84. DRsPSUIndex Name drsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only Table 85. DRsPSULocation Name drsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only Table 86. DRsPSUMonitoringCapable Name drsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.
Table 89. DRsPSUWattsReading Name drsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU wattage reading. Syntax DellPowerReading Access Read-only Chassis Servers The following MIB tables provide server information for the chassis being monitored by the chassis management controller. Table 90. DRsCMCServerTable Name drsCMCServerTable Object ID 1.3.6.1.4.1.674.10892.2.5.1 Description Defines the CMC server table.
Table 93. DRsServerMonitoringCapable Name drsServerMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.2 Description Defines the monitoring capabilities, or the absence of a server in this location. Syntax DellCMCServerCapable Access Read-only Table 94. DRsServerServiceTag Name drsServerServiceTag Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.3 Description Defines the Service Tag of the CMC server. Syntax DellString Access Read-only Table 95.
Table 98. DRsServerModel Name drsServerModel Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.7 Description This attribute defines the Model of the CMC server. Syntax DellString Access Read-only Table 99. DRsServerAssetTag Name drsServerAssetTag Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.8 Description This attribute defines the Asset Tag of the CMC server. Syntax DellString Access Read-only Table 100. DRsServerNumStorageControllers Name drsServerNumStorageControllers Object ID 1.3.6.1.4.1.674.
Table 103. DRsServerAssignedServerSlots Name drsServerAssignedServerSlots Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.12 Description This attribute defines the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or more server slots, the value will be a comma-separated list of one or more server slot names. If the storage sled is not assigned to a server slot, the value will be an empty string. If this is not a storage sled, the value will be N/A.
Description Defines the time stamp of the most recent change of the alerting subsystem. Syntax TimeTicks Access Read-only Table 108. DrsCAMessage Name drsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 109. DRsCA2MessageID Name drsCA2MessageID Object ID 1.3.6.1.4.1.674.10892.2.21.10.1 Description Defines the message ID of the alert.
Table 112. DrsCA2AlertStatus Name drsCA2AlertStatus Object ID 1.3.6.1.4.1.674.10892.2.21.10.4 Description Defines the status of the alert. Syntax DellStatus Access Read-only Table 113. DrsCA2FQDD Name drsCA2FQDD Object ID 1.3.6.1.4.1.674.10892.2.21.10.5 Description Defines the fully qualified device descriptor of device causing the alert. Syntax DisplayString Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 114.
Table 117. DRsAlertCurrentStatus Name drsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only Table 118. DRsAlertPreviousStatus Name drsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only Table 119. DRsAlertData Name drsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
SNMP Traps 3 SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
• Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function, such as crossing a failure threshold or a hardware failure. RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section.
TrapID Name Description Severity Category Cause Support ed by RAC Platfor m 1016 alertDrscSE L Critical The RAC has detected a new event in the System Event Log with Severity: Critical Critical Error RAC detected a new system event log with critical severity (detailed log info is in drsAlert Message varbind). All 1017 alertDrscSE L 80 percentFull The RAC system event log is 80% full Major Status RAC detected system event log is 80% full.
TrapID Description Severity 131840 Generic Critical Voltage Problem Cleared Information 65792 Under-Temperature Warning (Lower non-critical, going low) Warning 65920 Under-Temperature Warning Cleared Information 65794 Under-Temperature Problem (Lower Critical - going low) Critical 65922 Under-Temperature Problem Cleared Information 65799 Over-Temperature warning (Upper non-critical, going high) Minor 65927 Over-Temperature warning Cleared Information 65801 Over-Temperature Problem (
TrapID Description Severity 262400 Generic Predictive Fan Failure (predictive failure asserted) Minor 262528 Generic Predictive Fan Failure Cleared Information 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy has returned to Normal Information 2715392 Battery Low (Predictive Failure) Warning 2715520 Battery Low (Predictive F
TrapID Description Severity 487178 CPU Throttle (Processor Speed Reduced) Warning 487306 CPU Throttle Cleared (Normal Processor Speed) Information 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy has returned to Normal Information 552704 Power Supply Inserted Information 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Information 552706 Power
PowerEdge M1000e CMC Traps This section describes the traps that are generated by the SNMP agent of the PowerEdge M1000e CMC. All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with the following trap variables: drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem, drsCASSCurrStatus, drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage. PowerEdge M1000e CMC version 5.
Table 122. Amperage Probe Traps TrapID Description Category SubCategory Severity Status Events Amperage Information al Current sensor has detected Status Events a warning value. Amperage Minor Current sensor has detected Error Events a failure value. Amperage Critical Description SubCategory Severity Battery state has returned to Status Events normal; or battery presence had been detected. Battery Information al Battery is low.
Table 126. Fan Traps TrapID Description Category SubCategory Severity Fan information. Status Events Fan Information al Fan warning. Status Events Fan Minor Fan failure.
Table 129. Link Status Traps TrapID Description Category SubCategory Severity Link status information. Status Events Link Status Information al Link status warning. Status Events Link Status Minor Link status failure or critical event. Error Events Link Status Critical Description Category SubCategory Severity PCI device information. Status Events PCI Device Information al PCI device warning. Status Events PCI Device Minor PCI device failure or critical event.
Table 132. Power Supply Absent Trap TrapID Description Category SubCategory Severity Power supply is absent. Error Events Power Supply Critical Category SubCategory Severity Power usage information. Status Events Power Usage Information al Power usage warning. Status Events Power Usage Minor Power usage failure. Error Events Power Usage Critical Category SubCategory Severity Status Events Redundancy Information al Redundancy is degraded.
Table 136.
Table 139. Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage sensor reading is within range. Status Events Voltage Information al Voltage sensor has detected Status Events a warning value. Voltage Minor Voltage sensor has detected Error Events a failure value.
Table 142. Storage Enclosure Traps TrapID Description Category Subcategory Severity Error Events Enclosure Information al Error Events Enclosure Minor Error Events Enclosure Critical Category Subcategory Severity Storage fan information. Error Events Fan Information al Storage fan warning. Status Events Fan Minor Storage fan failure. Error Events Fan Critical alert2StorageEnclosureInformation 4339 Storage enclosure information.
TrapID Description Category Subcategory Severity 4234 Storage power supply warning. Error Events Power Supply Minor Error Events Power Supply Critical Category Subcategory Severity Status Events Security Event Information al Status Events Security Event Minor Error Events Security Event Critical Category Subcategory Severity Error Events Storage Management Information al Storage Management has Error Events detected a device independent warning condition.
Table 148. Storage Temperature Probe Traps TrapID Description Category Subcategory Severity Error Events Temperature Probe Information al Error Events Temperature Probe Minor Error Events Temperature Probe Critical Category Subcategory Severity Error Events Virtual Disk Information al Error Events Virtual Disk Minor Error Events Virtual Disk Critical alert2StorageTemperatureProbeInformation 4211 Storage temperature probe information.
Table 151. Audit IO Virtualization Traps TrapID Description Category SubCategory Severity Status Events IO Virtualization Minor Description Category SubCategory Severity License information. Status Events License Information al License warning. Status Events License Minor License failure.
TrapID Description Category SubCategory Severity 8417 Power usage audit failure or critical event. Error Events Power Usage Critical Category SubCategory Severity Error Events Software Change Critical Table 156. Audit Software Change Traps TrapID Description alert2SoftwareChangeAuditFailure 8361 Software change audit failure or critical event. Configuration Traps The Configuration Trap group contains traps that fall under the Configuration event category. Table 157.
Table 160. Configuration Test Traps TrapID Description Category SubCategory Severity Test trap generated by CMC in response to a user request. Status Events Test Information al alert2CMCTestTrap 10395 Updates Traps The Updates Trap group contains traps that fall under the Updates event category. Table 161. Software Change Traps TrapID Description Category Subcategory Severity Status Events Software Change Minor alert2SoftwareChangeUpdateWarning 6314 52 Software change update warning.
iDRAC MIB 4 The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRACSMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 and 8 (iDRAC7 and iDRAC8). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 and iDRAC8 of a system. NOTE: From iDRAC7 firmware release r1.30.
SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1, v2c and v3 TRAP SNMP v1, SNMP v2c and SNMP v3 NOTE: iDRAC does not support the SNMP SET operation for any data. NOTE: iDRAC7 firmware release r1.30.30 or later and iDRAC8 supports SNMP query operations (GET, GETNEXT, GETBULK) via the SNMPv3 protocol. In addition to supporting query operations via the SNMP v1 and SNMP v2c protocols, SNMP User Security Model (USM) is supported.
Description This attribute defines the product name of a remote access card. Syntax StringType Access Read-only Table 163. RAC Short Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access Read-only Table 164. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card.
Access Read-only Table 168. RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only Table 169. RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This attribute defines the firmware version of a remote access card.
Table 172. Chassis Model Modular Name chassisModelModular Object ID 1.3.6.1.4.1.674.10892.5.1.2.3.0 Description This attribute defines the model of the modular chassis. The value is zero length if not a modular system. Syntax StringType Access Read-only System Information Group The System Information Group objects provide information about the system in which the iDRAC resides. Table 173. System Fully Qualified Domain Name Name systemFQDN Object ID 1.3.6.1.4.1.674.10892.5.1.3.1.
Table 177. System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.6.1.4.1.674.10892.5.1.3.5.0 Description This attribute defines the slot number of the blade in the chassis. Syntax StringType Access Read-only Table 178. System Operating System Name Name systemOSName Object ID 1.3.6.1.4.1.674.10892.5.1.3.6.0 Description This attribute defines the name of the operating system that the host is running. Syntax StringType Access Read-only Table 179.
Description This attribute defines the Rack locator of the system. Syntax StringType Access Read-only Table 183. System Rack Slot Name systemRackSlot Object ID 1.3.6.1.4.1.674.10892.5.1.3.11.0 Description This attribute defines the Rack Slot locator of the system. Syntax StringType Access Read-only Table 184. System Model Name Name systemModelName Object ID 1.3.6.1.4.1.674.10892.5.1.3.12.0 Description This attribute defines the model name of the system.
Access Read-only Table 188. System Chassis System Height Name systemChassisSystemHeight Object ID 1.3.6.1.4.1.674.10892.5.1.3.16.0 Description This attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component. Syntax INTEGER Access Read-only Table 189. System Blade Geometry Name systemBladeGeometry Object ID 1.3.6.1.4.1.674.10892.5.1.3.17.
Description This attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included. Syntax ObjectStatusEnum Access Read-only Table 193. Global Storage Status Name globalStorageStatus Object ID 1.3.6.1.4.1.674.10892.5.2.3.0 Description This attribute defines the overall storage status being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 194. System Power State Name systemPowerState Object ID 1.3.
iDRAC Traps The iDRAC generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC. The iDRAC generates events in response to changes in the status of sensors and other monitored parameters. When an event with predefined characteristics occurs on your system, the SNMP subagent sends information about the event, along with trap variables, to the management console.
Table 197. Alert Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.5.3.1.2.0 Description Message describing the alert. Syntax StringType Table 198. Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 199. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.
Table 203. Alert Message Arguments Variable Name alertMessageArguments Object ID 1.3.6.1.4.1.674.10892.5.3.1.8.0 Description Concatenated set of strings representing the message arguments of the event. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 204.
TrapID Description 2178 Category SubCategory Severity Current sensor has detected System Health a warning value. Amperage Minor Current sensor has detected System Health a failure value. Amperage Critical Category SubCategory Severity Automatic system recovery (ASR) was performed. System Health Auto Sys Reset Critical Description Category SubCategory Severity Battery state has returned to System Health normal; or battery presence had been detected.
TrapID Description Category SubCategory Severity 2545 Chassis Management Controller detected an error. System Health CMC Critical Category SubCategory Severity System Health Processor Information al System Health Processor Minor System Health Processor Critical Description Category SubCategory Severity Processor device is absent. System Health Proc Absent Critical Description Category SubCategory Severity Fan information.
TrapID Description Category SubCategory Severity 2538 Fiber Channel warning. System Health Fiber Channel Minor Fiber Channel failure or critical event. System Health Fiber Channel Critical Category SubCategory Severity System Health Hardware Config Information al System Health Hardware Config Minor System Health Hardware Config Critical Description Category SubCategory Severity IO Virtualization failure or critical event.
Table 219. Memory Device Traps TrapID Description Category SubCategory Severity Memory device informational event. System Health Memory Information al Memory device status is noncritical. System Health Memory Minor Memory device status is critical. System Health Memory Critical Description Category SubCategory Severity Network information. System Health NIC Config Information al Network warning. System Health NIC Config Minor Network failure or critical event.
TrapID Description Category SubCategory Severity A warning event was detected for a PCI device. System Health PCI Device Minor An error was detected for a PCI device. System Health PCI Device Critical Description Category SubCategory Severity Physical disk information. System Health Physical Disk Information al Physical disk warning. System Health Physical Disk Minor Physical disk failure.
Table 226. Power Supply Absent Trap TrapID Description Category SubCategory Severity Power supply is absent. System Health PSU Absent Critical Description Category SubCategory Severity System performance restored. System Health Power Usage Information al System performance degraded. System Health Power Usage Minor The system halted because system power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold.
TrapID Description Category SubCategory Severity 2210 Integrated Dual SD Module warning. System Health IDSDM Media Minor System Health IDSDM Media Critical Category SubCategory Severity System Health IDSDM Absent Critical Category SubCategory Severity System Health IDSDM Redundancy Information al System Health IDSDM Redundancy Minor System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information.
Table 233. System Event Log Traps TrapID Description Category SubCategory Severity System Health Sys Event Log Information al System Event Log warning. System Health Sys Event Log Minor System Event Log failure or critical event.
Table 236. Temperature Statistics Traps TrapID Description Category SubCategory Severity Temperature Statistics Minor Temperature Statistics Critical Category SubCategory Severity System Health vFlash Event Information al System Health vFlash Event Minor System Health vFlash Event Critical Category SubCategory Severity vFlash Media device is absent. System Health vFlash Absent Information al Description Category SubCategory Severity RAC information.
Table 240. Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage sensor reading is within range. System Health Voltage Information al Voltage sensor has detected System Health a warning value. Voltage Minor Voltage sensor has detected System Health a failure value. Voltage Critical Category SubCategory Severity System Health Performance Minor Voltage Probe Normal 2171 Voltage Probe Warning 2170 Voltage Probe Failure 2169 Table 241.
TrapID Description Category SubCategory Severity 4330 Controller warning. Storage Storage Contr Minor Controller failure. Storage Storage Contr Critical Description Category SubCategory Severity Storage Storage Enclosr Information al Storage Storage Enclosr Minor Enclosure failure. Storage Storage Enclosr Critical Description Category SubCategory Severity Fan information. Storage Fan Event Information al Fan warning. Storage Fan Event Minor Fan failure.
Table 247. Power Supply Traps TrapID Description Category SubCategory Severity Storage Power Supply Information al Storage Power Supply Minor Storage Power Supply Critical Category SubCategory Severity Security event information. Storage Security Event Information al Security event warning. Storage Security Event Minor Security event failure or critical Storage event.
Table 250. Temperature Probe Traps TrapID Description Category SubCategory Severity Storage Temperature Information al Storage Temperature Minor Temperature probe failure. Storage Temperature Critical Description Category SubCategory Severity Storage Virtual Disk Information al Storage Virtual Disk Minor Storage Virtual Disk Critical Storage Temperature Probe Information 4211 Temperature probe information. Storage Temperature Probe Warning 4210 Temperature probe warning.
Table 254. CMC Traps TrapID Description Category SubCategory Severity Chassis Management Audit Controller audit information. CMC Informational Chassis Management Controller audit warning. Audit CMC Minor Chassis Management Controller audit failure or critical event. Audit CMC Critical Description Category SubCategory Severity Debug authorized. Audit Debug Informational Debug authorization failed.
Table 259. PCI DeviceTraps TrapID Description Category SubCategory Severity PCI device audit warning. Audit PCI Device Minor Category SubCategory Severity Power Supply Minor Power Supply Critical Category SubCategory Severity Audit Power Usage Informational Audit Power Usage Minor Audit Power Usage Critical Category SubCategory Severity Audit System Info Informational PCI Device Audit Warning 8562 Table 260.
Table 263. Auto Discovery Traps TrapID Description Category SubCategory Severity Auto Discovery Information 10635 Auto discovery information. Configuration Auto Discovery Informationa l Category Severity Table 264. NIC Configuration Traps TrapID Description SubCategory Network Configuration Information 10771 Network configuration information. Configuration IOID Informationa l Network configuration warning.
Table 269. Software Configuration Traps TrapID Description Category SubCategory Severity SWC Configuration Warning 10530 Software configuration warning. Configuration Software Config Minor SWC Configuration Failure 10529 Software configuration failure. Configuration Software Config Critical Description Category Severity The iDRAC generated a test trap event in response to a user request. Configuration Test Alert Table 270.