Users Guide
Table 92. omreport controller commands
Required command levels 
(1, 2, 3)
Optional name=value pairs Use
omreport storage 
controller
Displays property information for all controllers attached to the 
system.
controller=id, where id is the 
controller number. For example, 
controller=0
Displays the specified controller and all attached components 
such as enclosures, virtual disks, physical disks, HHHL cards, and 
so on.
controller=id info=foreignkeyids Displays the locked foreign configuration information for import 
or clear operations.
controller=id info=pdslotreport
Displays the empty and occupied slot details of enclosures in the 
controller.
NOTE: This command is not supported on Blackplane, 
SCSI, and SWRAID controllers.
Omreport Enclosure Status
The following sections provide the omreport storage enclosure command syntax required to execute the enclosure commands. The 
following table describes the syntax for the omreport Enclosure commands.
Table 93. omreport Enclosure Commands
Required Command 
Levels (1, 2, 3)
Optional name=value pairs Use
omreport storage 
enclosure
Displays property information for all enclosures 
attached to the system.
controller=id, where id is the controller number Displays all enclosures connected to the 
controller.
controller=id enclosure=<ENCLOSUREID>, where 
id is the controller number and 
<ENCLOSUREID>is the enclosure ID. Example for 
SCSI controllers: controller=0 enclosure=2. 
Example for SAS controllers: controller=0 
enclosure=1:2.
Displays the specified enclosure and its 
components.
Omreport Temperature Probe Status
The following table describes the syntax for the omreport Probe commands:
Table 94. omreport Temperature Probe Commands
Required Command Levels (1, 2, 3) and 
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all 
enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID> 
info=temps where id is the controller 
number and <ENCLOSUREID> is the 
enclosure ID. Example for SCSI controllers: 
controller=0 enclosure=2 info=temps. 
Displays the temperature probes for the 
specified enclosure.
130