Users Guide
Required Command Levels (1, 2, 3) and 
name=value pair
Optional name=value pairs Use
info=pwrsupplies where id is the controller 
number and ENCLOSUREID is the 
enclosure number. For example: 
controller=0 enclosure=2
controller=id 
enclosure=<ENCLOSUREID> 
info=pwrsupplies index=n where id is the 
controller number and ENCLOSUREID is 
the enclosure number and n is the number 
of a power supply. For example: 
controller=0 enclosure=2 
info=pwrsupplies index=1
Displays the specified power supply.
Omreport EMM Status
The following table describes the syntax for the omreport EMM commands:
NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware.
Table 97. Omreport EMM Commands
Required Command Levels (1, 2, 3) and 
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all 
enclosures attached to the system.
controller=id 
enclosure=<ENCLOSUREID> info=emms 
where id is the controller number and 
ENCLOSUREID is the enclosure number. 
For example: controller=0 enclosure=2
Displays the enclosure management 
modules (EMMs) for the specified 
enclosure.
controller=id 
enclosure=<ENCLOSUREID> info=emms 
index=n where id is the controller number 
and ENCLOSUREID is the enclosure 
number and n is the number of an EMM. 
For example: controller=0 enclosure=2 
info=emms index=1
Displays the specified EMMs.
Omreport Enclosure Slot Occupancy Report
The following table describes the syntax for the omreport Enclosure Slot Occupancy Report commands:
Table 98. Omreport Enclosure Slot Occupancy Report Commands
Required Command Levels (1, 2, 3) and 
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all 
enclosures attached to the system.
controller=id 
enclosure=<ENCLOSUREID> 
info=pdslotreport, where id is the 
Displays the empty and occupied slot 
details for the specified enclosure.
132