Users Guide
Omconfig Enable Device Write Cache
Table 122. omconfig Enable Device Write Cache
Description
Enables write cache on a physical disk for the PCIe SSD 
controller.
Syntax
omconfig storage pdisk 
action=enabledevicewritecache controller=id 
pdisk=<PDISKID>, where id is the controller ID. The 
<PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage 
controller
 to display the controller IDs and then type 
omreport storage pdisk controller=ID to display the IDs 
for the physical disks attached to the controller.
Example to Enable write cache on physical disk 3 on connector 0 of 
controller 1. On a SAS controller, the physical disk resides in 
enclosure 2.
Example for SAS controllers
omconfig storage pdisk 
action=enabledevicewritecache controller=1 
pdisk=0:2:3
Omconfig Disable Device Write Cache
Table 123. omconfig Disable Device Write Cache
Description
Disables write cache on a physical disk for the PCIe SSD 
controller.
Syntax
omconfig storage pdisk 
action=disabledevicewritecache controller=id 
pdisk=<PDISKID>, where id is the controller ID. The 
<PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport storage 
controller
 to display the controller IDs and then type 
omreport storage pdisk controller=ID to display the IDs 
for the physical disks attached to the controller.
Example to Disable write cache on physical disk 3 on connector 0 of 
controller 1. On a SAS controller, the physical disk resides in 
enclosure 2.
Example for SAS controllers 
omconfig storage pdisk 
action=disabledevicewritecache controller=1 
pdisk=0:2:3
Omconfig Export Reliability Log
Table 124. omconfig Export Reliability Log
Description
Exports log on a physical disk or the NVMe adapter. The 
reliability log for the device PCIe SSD device or NVMe device is 
144