CLI Guide
Omreport Temperature Probe Status
The following table describes the syntax for the omreport Probe commands:
Table 96. omreport Temperature Probe Commands
Required Command Levels (1, 2, 3) and 
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all 
enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID> 
info=temps where id is the controller number 
and <ENCLOSUREID> is the enclosure ID. 
Example for SCSI controllers: controller=0 
enclosure=2 info=temps. Example for SAS 
controllers: controller=0 enclosure=1:2 
info=temps
Displays the temperature probes for the 
specied enclosure.
controller=id enclosure=<ENCLOSUREID> 
info=temps index=n where id is the controller 
number and <ENCLOSUREID> is the 
enclosure number and n is the number of a 
temperature probe. For example: controller=0 
enclosure=2 info=temps index=1
Displays the temperature probes for the 
specied enclosure.
Omreport Fan Status
The following table describes the syntax for the omreport Fan commands:
Table 97. omreport Fan Status
Required Command Levels (1, 2, 3) and 
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all 
enclosures attached to the system.
controller=id enclosure=<ENCLOSUREID> 
info=fans where id is the controller number 
and ENCLOSUREID is the enclosure number. 
For example: controller=0 enclosure=2
NOTE: For SCSI controllers, the ID 
specied in 
enclosure=<ENCLOSUREID> is the 
connector number and for Serial 
Attached SCSI (SAS) controllers, ID 
is the 
connectorNumber:EnclosureIndex.
Displays the fans for the specied enclosure.
controller=id enclosure=<ENCLOSUREID> 
info=fans index=n where id is the controller 
Displays the specied fan.
140 Omreport storage commands