CLI Guide
autoreplacememberonpredictivefailure= <enabled 
| disabled> persistenthotspare=<enabled | 
disabled> nrdiskcachepolicy=<enabled | disabled 
|unchanged>
Example to 
Example 
Enable revertible hot spare and replace member operation.
omconfig storage controller action= 
setchangecontrollerproperties 
allowrevertiblehotspare 
andreplacemember=enabled controller=1
Example to
Example
Allows to enable, disable, or not to change the Non-RAID Hard Disk 
Drives. This is applicable only to Disk Cache Policy.
omconfig storage controller action= 
setchangecontrollerproperties controller=1 
nrdiskcachepolicy=enabled
Omcong Discard Preserved Cache
Table 173. Omcong Discard Preserved Cache
Description Discards the preserved cache on the controller.
NOTE: To check if the controller has a preserved cache, type omreport storage controller 
controller=id. If the system displays Preserved Cache=yes, it indicates the presence of the 
preserved cache.
Syntax
omconfig storage controller action= discardpreservedcache controller=id 
force=enabled | disabled
If you set force=enabled, the cache is discarded irrespective of whether the controller detects a foreign or an oine 
virtual disk.
Example to  Discard the preserved cache.
Example
omconfig storage controller action= discardpreservedcache controller=1 force=enabled 
CAUTION: Discarding the preserved cache can result in data loss. It is recommended that you run this 
command using the force=disabled option.
NOTE: If a foreign conguration is detected, then the preceding command using force=disabled option 
fails. To avoid data loss, import the foreign conguration and ush the preserved cache to disk. To discard 
preserved cache forcefully, either clear the foreign conguration and run the proceeding command, or run 
the proceeding command using force=enabled option.
178 Omcong storage commands