CLI Guide
NOTE: On PERC 7 controllers, only spindownunconfigureddrives, spindownhotspares, and 
spindowntimeinterval parameters are supported.
NOTE: You can specify spinupstarttime and spinuptimeinterval only when you set 
spindownconfigureddrives=enabled.
Example to  Spin down drives that are not congured or hot spares that are unattended for 30 minutes
Example
omconfig storage controller action= setpdiskpwrmanagement 
spindownunconfigureddrives= enabled spindownhotspares=enabled 
spindowntimeinterval=30 controller=1
Omcong set controller mode
Table 186. Omcong set controller mode
Description Sets the mode of the controller to RAID or HBA.
Syntax omconfig storage controller action=setcontrollermode controller=id mode=raid|hba, 
where id is the controller ID as reported by the omreport storage controller command.
NOTE: If a virtual disk, hotspare, or encryption key is enabled on the controller, the controller mode cannot 
be changed to HBA. Reboot the system for the change to take eect.
Example to  Set the controller mode to HBA.
Example
omconfig storage controller action=setcontrollermode controller=1 mode=hba
Omcong autocongure RAID0
Table 187. 
Omcong autocongure RAID-0
Description Automatically congures RAID–0 with all disks that are in ready state.
Syntax omconfig storage controller action=autoconfigureRAID0 controller=id , where id is the 
controller ID as reported by the omreport storage controller command.
Example to  Automatically congure RAID–0 with other disks.
Example
omconfig storage controller action=autoconfigureRAID0 controller=1 
Omcong storage commands 183