CLI Guide
Required Command Levels 
(1, 2, 3)
Optional name=value pairs
action=setalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
action=resetalltempprobes controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
action=blink controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n
Omcong Enable Enclosure Alarm
Table 197. Omcong Enable Enclosure Alarm
Description Enables the enclosure alarm
Example to Enable the alarm on the enclosure attached to connector 2 on controller 1.
Example for SCSI, SATA, 
and ATA controllers 
omconfig storage enclosure action=enablealarm controller=1 enclosure=2
Example for SAS controllers 
omconfig storage enclosure action=enablealarm controller=1 enclosure=1:2
Omcong Disable Enclosure Alarm
Table 198. 
Omcong Disable Enclosure Alarm
Description Disables the enclosure alarm.
Syntax
omconfig storage enclosure action=disablealarm controller=id 
enclosure=<ENCLOSUREID>, where idis the controller ID. The <ENCLOSUREID> variable species 
the enclosure.
Example to Disables the alarm on enclosure 2 attached to connector 1 on controller 1.
Example for SCSI, SATA, 
and ATA controllers 
omconfig storage enclosure action=disablealarm controller=1 enclosure=2
Example for SAS controllers 
omconfig storage enclosure action=disablealarm controller=1 enclosure=1:2
Omcong Set Enclosure Asset Tag
Table 199. 
Omcong Set Enclosure Asset Tag
Description Species the enclosure’s asset tag.
Syntax
omconfig storage enclosure action=setassettag controller=id 
enclosure=<ENCLOSUREID> assettag=<string>, where id is the controller ID. The 
<ENCLOSUREID> variable species the enclosure.
In this syntax, <string> is a user-specied alphanumeric string.
Omcong storage commands 187