Users Guide
Supported Features On PERC Software RAID Controllers
This section identies the controller-supported features and whether an enclosure can be attached to the PERC 6/E, PERC 6/I, and PERC 
6/I Modular controllers. The Software RAID controllers include PERC S140 Controller.
• Controller Tasks
• Physical Disk Tasks
• Virtual Disk Tasks
• Virtual Disk Specications
• Supported RAID Levels
• Read, Write, Cache And Disk Cache Policy
• Enclosure Support
For enclosure-supported tasks, see Enclosure And Backplane Features.
Controller Tasks Supported On The PERC Software RAID 
Controllers
Table 44. Controller Tasks Supported On The PERC S100, PERC S110, PERC S130, PERC S300 and S140 Controllers
Controller Task 
Name
PERC S100 PERC S110 PERC S130 PERC S300 PERC S140
Create Virtual 
Disk 
Yes Yes Yes Yes Yes
NOTE: For physical disks connected to Software RAID S130 controller, 512 MB of disk space is by default used by the controller 
for metadata.
Physical Disk Tasks Supported By The PERC Software RAID 
Controllers
Table 45. Physical Disk Tasks Supported by the PERC S100, PERC S110, PERC S130, PERC S300 and S140 Controllers
Physical Disk 
Task Name
PERC S100 PERC S110 PERC S130 PERC S300 PERC S140
Blink/Unblink  No Yes Yes No Yes
Assign and 
Unassign Global 
Hot Spare 
Yes Yes Yes Yes Yes
Set Disk Cache 
Policy
No No Yes No Yes
Export Log No No Yes No Yes
Supported Features 179