CLI Guide
• Reading
• System Peak Power
• System Peak Amperage
NOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable 
from PowerEdge 10G system onwards that support PMBus and that have hot-swappable power supplies and not 
systems that have a fixed, non-redundant power supply installed.
NOTE: Power monitoring requires license to report the details. If the appropriate license is not installed or has expired, 
the system does not display the power consumption details of the system. For more information, see the 
Dell License 
Manager 
at Guide dell.com/openmanagemanuals.
NOTE: To maintain consistency across the commands, the output format of this command and the subsequent 
command levels has changed. So, you may have to change the user scripts as applicable.
An example output reporting power statistics in Watts is as follows:
Table 29. Power statistics in watts
Power Consumption Information 
Power Consumption 
Index  : 1
Status  : Ok
Probe Name  : System Board Pwr Consumption 
Reading  : 539W 
Warning Threshold  : 994W 
Failure Threshold  : 1400 W 
Amperage 
PS1 Current 1  : 1.2 A
Power Headroom 
System Instantaneous Headroom  : 300 W
System Peak Headroom  : 340 W 
Power Tracking Statistics
Statistic  : Energy consumption 
Measurement Start Time  : Thu May 28 11:03:20 2011 
Measurement Finish Time  : Fri May 28 11:05:46 2011 
Reading  : 5.9 KWH
Statistics  : System Peak Power
Measurement Start Time  : Mon May 18 16:03:20 2011
Peak Time  : Wed May 27 00:23:46 2011
Peak Reading  : 630 W 
Statistics  : System Peak Amperage
Measured Since  : Mon May 18 16:03:20 2011 
Read Time  : Tue May 19 04:06:32 2011
Peak Reading  : 2.5 A
NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies 
and not systems that have a fixed, non-redundant power supply installed.
36 omreport Viewing System Status Using The Instrumentation Service