Users Guide
Controller Starting RAID Level Target RAID Level Comments
Blades, PERC H710P Mini 
Monolithic, PERC H810 Adapter, 
PERC H330 Adapter, PERC 
H330 Mini Monolithic, PERC 
H330 Mini Blades, PERC H330 
Embedded, PERC H730 Adapter, 
PERC H730 Mini Monolithic, 
PERC H730 Mini Blades, PERC 
H730P Adapter, PERC H730P 
Mini Monolithic, PERC H730P 
Mini Blades, PERC H730P Slim, 
PERC H740P Adapter, PERC 
H740P Mini Monolithic, PERC 
H830 Adapter, PERC H840 
Adapter, PERC H730P MX, 
PERC H745P MX and PERC 
FD33xD/FD33xS
exceeds the 4-disk minimum 
required by RAID 6
RAID 1 RAID 0 With or without adding 
additional disks
RAID 1 RAID 5, RAID 6 Add at least one additional disk.
RAID 6 requires a minimum of 4 
disks.
RAID 5 RAID 0 With or without adding 
additional disks
RAID 5 RAID 5, RAID 6 Add at least one additional disk.
RAID 6 requires a minimum of 4 
disks.
RAID 6 RAID 0, RAID 5 With or without adding 
additional disks
RAID 6 RAID 6 Add at least one additional disk
RAID 10 RAID 10 Without adding additional disks
PERC S100, S110, S130, S140 
and S300
RAID 0 RAID 0 With or without additional disks
RAID 1 RAID 1 Without additional disks
RAID 5 RAID 5 With or without additional disks
RAID 10 RAID 10 Without additional disks
NOTE: The order of the controllers displayed on Storage Management may dier with the order of the controllers displayed in 
the Human Interface (HII) and PERC Option ROM. The order of the controllers does not cause any limitation.
NOTE: When creating virtual disks using software RAID controllers, the information related to the physical disks linked to the 
virtual disk is enumerated or displayed on Storage Management after a short delay. This delay in displaying the information does 
not cause any functional limitation. If you are creating partial virtual disks, it is recommended that you provide Storage 
Management adequate time between each partial virtual disk creation process.
NOTE: RAID 10 virtual disk reconguration operation is not supported with Intelligent Mirroring.
Maintaining The Integrity Of Redundant Virtual Disks
Does my controller support this feature? See Supported Features.
The virtual disk Check Consistency task veries the accuracy of the redundant (parity) information. This task only applies to redundant 
virtual disks. When necessary, the Check Consistency task rebuilds the redundant data.
To verify redundant information of a virtual disk:
1  Locate the controller on which the virtual disk resides in the tree view. Expand the controller object until the Virtual Disks object is 
displayed.
2  Select the Check Consistency task from the virtual disk’s Tasks drop-down list box and click Execute.
Rebuilding Redundant Information
Does my controller support this feature? See Supported Features.
Virtual Disks
123