This damage is discovered when the controller performs an operation that requires scanning the disk. Examples of operations that may
result in these alerts are as follows:
Consistency check
Rebuild
Virtual disk format
I/O
If you receive alerts 2146 through 2150 as the result of performing a rebuild or while the virtual disk is in a degraded state, then data cannot
be recovered from the damaged disk without restoring from the backup. If you receive alerts 2146 through 2150 under circumstances other
than a rebuild, then data recovery may be possible. The following describes each of these situations.
Alerts 2146 Through 2150 Received During A Rebuild Or While
A Virtual Disk Is Degraded
Perform the following steps:
1 Replace the damaged physical disk.
2 Create a new virtual disk and allow the virtual disk to completely resynchronize.
While the resynchronization is in progress, the status of the virtual disk is Resynching.
3 Restore data to the virtual disk from the backup.
Alerts 2146 Through 2150 Received While Performing IO,
Consistency Check, Format, Or Other Operation
If you receive alerts 2146 through 2150 while performing an operation other than a rebuild, replace the damaged disk immediately to avoid
data loss.
Perform the following steps:
1 Back up the degraded virtual disk to a fresh (unused) tape drive.
2 Replace the damaged disk.
3 Perform a rebuild.
Read And Write Operations Experience Problems
If the system hangs, times out, or experiences other problems with read and write operations, then there may be a problem with the
controller cables or a device.
A Task Menu Option Is Not Displayed
You may notice that the task menus do not always display the same task options. Some tasks are only valid for certain types of objects or
at certain times. For example, a Check Consistency task can only be performed on a redundant virtual disk. Similarly, if a disk is already
oine, the Oine task option is not displayed.
There may be other reasons why a task cannot be run at a certain time. For example, there may already be a task running on the object
that must complete before additional tasks can be run.
Troubleshooting