CLI Guide
NOTE: To obtain these values, type omreport storage 
controller to display the controller IDs and then type 
omreport storage pdisk controller=ID to display the IDs for 
the physical disks attached to the controller.
Example to Erase physical disk 3 on connector 0 of controller 1. On a SAS 
controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk 
action=cryptographicerase controller=1 
pdisk=0:3
Example for SAS controllers 
omconfig storage pdisk 
action=cryptographicerase controller=1 
pdisk=0:2:3
Omcong Initialize Physical Disk
Table 115. omcong Initialize Physical Disk
Description
Initializes a physical disk.
Syntax
omconfig storage pdisk action=initialize 
controller=id pdisk=id, where id is the controller ID and 
physical disk ID as reported by the omreport command.
NOTE: To obtain these values, type omreport storage 
controller to display the controller IDs and then type 
omreport storage pdisk controller=ID to display the IDs for 
the physical disks attached to the controller.
Example to Initialize physical disk 4 on controller 1
Example
omconfig storage pdisk action=initialize 
controller=1 pdisk=1:0:4
Omcong Oine Physical Disk
Table 116. 
omcong Oine Physical Disk
Description
Makes a physical disk oine.
Syntax
omconfig storage pdisk action=offline 
controller=id pdisk=<PDISKID>, where id is the controller 
ID. The <PDISKID> variable species the physical disk.
NOTE: To obtain these values, type omreport storage 
controller to display the controller IDs and then type 
omreport storage pdisk controller=ID to display the IDs for 
the physical disks attached to the controller.
Example to Oine physical disk 3 on connector 0 of controller 1. On a SAS 
controller, the physical disk resides in enclosure 2.
144 Omcong storage commands










