CLI Guide

Omcong Set Reconstruct Rate
Table 178. Omcong Set Reconstruct Rate
Description Sets the reconstruct rate.
Syntax
omconfig storage controller action= setreconstructrate controller=id rate=<0 to
100>, where id is the controller ID as reported by the omreport storage controller command.
Example to Set the reconstruct rate to 50 on controller 1.
Example
omconfig storage controller action= setreconstructrate controller=1 rate=50
Omcong Set Check Consistency Rate
Table 179. Omcong Set Check Consistency Rate
Description Sets the check consistency rate.
Syntax
omconfig storage controller action= setcheckconsistencyrate controller=id rate=<0 to
100>, where id is the controller ID as reported by the omreport storage controller command.
Example to Sets the check consistency rate to 50 on controller 1.
Example
omconfig storage controller action= setcheckconsistencyrate controller=1 rate=50
Omcong Export The Controller Log
Table 180.
Omcong Export The Controller Log
Description Exports the controller log to a text le. For more information about the exported log le, see the Dell EMC OpenManage
Online Help.
Syntax omconfig storage controller action=exportlog controller=id, where id is the controller ID as
reported by the omreport storage controller command.
Example to Export the log on controller 1.
Example
omconfig storage controller action=exportlog controller=1
By default, the log le is exported to C:\WINNT or C:\Windows on Microsoft Windows systems (based on the Windows
version used) and /var/logon all Linux systems.
Depending on the controller, the log le name is afa_<mmdd>.log or lsi_<mmdd>.log where <mmdd> is the month and
date. For more information on the controller log le, see the Dell EMC OpenManage Online Help .
NOTE: The export log le command is not supported on the 4/IM, CERC ATA, and 100/4ch
controllers.
174 Omcong storage commands