CLI Guide
Omcong Set Reconstruct Rate
Table 178. Omcong Set Reconstruct Rate
Description Sets the reconstruct rate.
Syntax
omconfig storage controller action= setreconstructrate controller=id rate=<0 to
100>, where id is the controller ID as reported by the omreport storage controller command.
Example to Set the reconstruct rate to 50 on controller 1.
Example
omconfig storage controller action= setreconstructrate controller=1 rate=50
Omcong Set Check Consistency Rate
Table 179. Omcong Set Check Consistency Rate
Description Sets the check consistency rate.
Syntax
omconfig storage controller action= setcheckconsistencyrate controller=id rate=<0 to
100>, where id is the controller ID as reported by the omreport storage controller command.
Example to Sets the check consistency rate to 50 on controller 1.
Example
omconfig storage controller action= setcheckconsistencyrate controller=1 rate=50
Omcong Export The Controller Log
Table 180.
Omcong Export The Controller Log
Description Exports the controller log to a text le. For more information about the exported log le, see the Dell EMC OpenManage
Online Help.
Syntax omconfig storage controller action=exportlog controller=id, where id is the controller ID as
reported by the omreport storage controller command.
Example to Export the log on controller 1.
Example
omconfig storage controller action=exportlog controller=1
By default, the log le is exported to C:\WINNT or C:\Windows on Microsoft Windows systems (based on the Windows
version used) and /var/logon all Linux systems.
Depending on the controller, the log le name is afa_<mmdd>.log or lsi_<mmdd>.log where <mmdd> is the month and
date. For more information on the controller log le, see the Dell EMC OpenManage Online Help .
NOTE: The export log le command is not supported on the 4/IM, CERC ATA, and 100/4ch
controllers.
174 Omcong storage commands