CLI Guide

Cause : [N/A]
Omreport Chassis Info Or Omreport Mainsystem Info
Use the omreport chassis info or omreport mainsystem info command to see a summary of installed component versions. Type:
omreport chassis info index=n
or
omreport mainsystem info index=n
The index parameter species a chassis number and is optional. If you do not specify the index, Server Administrator displays summary
chassis information for each chassis. If you specify the index, Server Administrator displays summary information for a specic chassis.
NOTE: If iDRAC is installed, Server Administrator displays the Lifecycle Controller version. If BMC is installed, Server
Administrator displays the USC version.
Depending on the system’s conguration, you may notice the following output:
Table 15. System conguration output
Index : 0
Chassis Name : Main System Chassis
Host Name : WIN-27C02UQFV6L
iDRAC7 Version : 1.00
Chassis Model : PowerEdge R720
Chassis Lock : Present
Chassis Service Tag : 7654321
Express Service Code : 15608862073
Chassis Asset Tag : c
Omreport Chassis Intrusion
Use the omreport chassis intrusion command to nd out whether the cover of the system is open or not. Server Administrator tracks
chassis intrusion events because intrusions may indicate an attempt to steal a system component, or to perform unauthorized maintenance
on the system. Type:
omreport chassis intrusion
A message that resembles the following is displayed:
Table 16. Output
Intrusion Information
Health : Ok
Index : 0
Status : OK
Probe Name : Intrusion
State : Chassis is closed
28 omreport Viewing System Status Using The Instrumentation Service