CLI Guide

NOTE: Power monitoring requires license to congure the power budget information. If the appropriate license is not installed or
has expired, the system displays an error message. For more information, see
Dell License Manager
at dell.com/
openmanagemanuals.
Default warning thresholds
NOTE: Sensor managing capabilities vary across systems.
To set both the upper and lower power consumption probe warning threshold values to the recommended default value, type:
omconfig chassis pwrmonitoring config=probe index=0 warnthresh=settodefault
or
omconfig mainsystem pwrmonitoring config=probe index=0 warnthresh=settodefault
You cannot default one value and set another. If you default the minimum warning threshold value, you are also selecting the default value
for the maximum warning threshold value.
Specify A Value For Warning Thresholds
If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the probe you are
conguring and the warning threshold value. Congure the values to display either in BTU/hr or Watts. In the following example, the probe
that is being congured is probe 4:
omconfig chassis pwrmonitoring config=probe index=4 warnthresh=325 unit=watt
or
omconfig mainsystem pwrmonitoring config=probe index=4 warnthresh=325 unit=btuphr
When you issue the command and the system sets the values you specify, the following message is displayed:
Power consumption probe warning threshold(s) set successfully.
Omcong chassis remoteaccess or omcong mainsystem
remoteaccess
Use the omcong chassis remoteaccess or omcong mainsystem remoteaccesscommand to congure:
Remote access on a local area network (LAN).
The serial port for BMC or RAC, whichever is installed.
The BMC or RAC on a serial over LAN connection.
Terminal settings for the serial port.
Advanced settings for a serial over LAN connection.
Information on a BMC or RAC user.
Information on IPv6 and IPv4 interfaces.
NOTE
: Enter the user ID to congure user information.
Type:
omconfig chassis remoteaccess
or
omconfig mainsystem remoteaccess
Omcong
Managing Components Using The Instrumentation Service 83