id=user id
congureidrac=true | false true or false: Enables or disables
conguration of iDRAC.
Omcong Chassis Temps Or Omcong Mainsystem Temps
Use the omcong chassis temps or omcong mainsystem temps command to set warning thresholds for temperature probes. As with
other components, you can view both warning and failure threshold values, but you cannot set failure threshold values. The system
manufacturer sets the minimum and maximum failure threshold values.
NOTE: Threshold values that you can set vary from one system conguration to another.
Valid Parameters For Temperature Warning Thresholds
The following table displays the valid parameters for setting temperature warning thresholds:
Table 58. Valid Parameters For
Omcong Chassis Temps Or Omcong Mainsystem Temps
name=value pair Description
index=<n> Number of the probe or probe index (specify).
warnthresh=default Sets the minimum and maximum warning threshold values to default.
minwarnthresh=<n> Sets the minimum warning threshold values (one decimal place).
maxwarnthresh=<n> Sets the maximum warning threshold values (one decimal place).
Setting Minimum And Maximum Warning Threshold Values
To set both the upper and lower temperature warning threshold values to the recommended default value, type:
omconfig chassis temps index=0 warnthresh=default
or
omconfig mainsystem temps index=0 warnthresh=default
You cannot default one value and set another. In other words, if you set the minimum warning threshold value to the default value, you are
also selecting the default value for the maximum warning threshold value.
NOTE
: The capabilities for managing sensors vary by systems.
Specify a value for minimum and maximum warning thresholds
To specify values for the temperature probe warning thresholds, you must specify the number of the probe you are conguring and the
minimum and/or maximum warning threshold value. In the following example, the probe that is being congured is probe 4:
omconfig chassis temps index=4 minwarnthresh=11.2 maxwarnthresh=58.7