Dell Event Message Reference
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Information in this publication is subject to change without notice. © 2012 Dell Inc. All rights reserved. Printed in the U.S.A.
Contents Notes, Cautions, and Warnings...................................................................................................2 1 Introduction................................................................................................................................57 2 AMP Event Messages..............................................................................................................59 AMP0300........................................................................................
ASR0100..................................................................................................................................................................73 ASR0101..................................................................................................................................................................74 ASR0102.................................................................................................................................................................
BAR032....................................................................................................................................................................91 BAR033....................................................................................................................................................................92 BAR034................................................................................................................................................................
BAR074..................................................................................................................................................................109 BAR075..................................................................................................................................................................109 BAR076..................................................................................................................................................................
BAT0001................................................................................................................................................................127 BAT0002................................................................................................................................................................128 BAT0003................................................................................................................................................................
BAT1023................................................................................................................................................................147 BAT1024................................................................................................................................................................147 BAT1025................................................................................................................................................................
BOOT004...............................................................................................................................................................168 BOOT005...............................................................................................................................................................168 BOOT006...............................................................................................................................................................
CPU0702................................................................................................................................................................187 CPU0703................................................................................................................................................................188 CPU0704................................................................................................................................................................
CTL30.....................................................................................................................................................................207 CTL31.....................................................................................................................................................................207 CTL32...............................................................................................................................................................
CTL69.....................................................................................................................................................................228 CTL7......................................................................................................................................................................228 CTL70...............................................................................................................................................................
14 DKM Event Messages..........................................................................................................247 DKM0001...............................................................................................................................................................247 DKM0002...............................................................................................................................................................247 DKM0003..................................
ENC40....................................................................................................................................................................265 ENC5.....................................................................................................................................................................266 ENC6..................................................................................................................................................................
HWC1007...............................................................................................................................................................287 HWC1008...............................................................................................................................................................287 HWC1009...............................................................................................................................................................
HWC5002...............................................................................................................................................................306 HWC5003...............................................................................................................................................................306 HWC5004...............................................................................................................................................................
JCP008..................................................................................................................................................................324 JCP009..................................................................................................................................................................324 JCP010..................................................................................................................................................................
LC020.....................................................................................................................................................................342 LC021.....................................................................................................................................................................342 LC022...............................................................................................................................................................
22 LIC Event Messages.............................................................................................................361 LIC000....................................................................................................................................................................361 LIC001....................................................................................................................................................................361 LIC002........................
LIC903....................................................................................................................................................................379 LIC904....................................................................................................................................................................379 LIC905..............................................................................................................................................................
MEM1000..............................................................................................................................................................399 MEM1001..............................................................................................................................................................400 MEM1002..............................................................................................................................................................
NIC006...................................................................................................................................................................419 NIC007...................................................................................................................................................................419 NIC008................................................................................................................................................................
OSD14...................................................................................................................................................................437 OSD15...................................................................................................................................................................437 OSD16...................................................................................................................................................................
OSD52...................................................................................................................................................................455 OSD53...................................................................................................................................................................455 OSD54...................................................................................................................................................................
PCI1308.................................................................................................................................................................473 PCI1310.................................................................................................................................................................473 PCI1312.................................................................................................................................................................
31 PR Event Messages..............................................................................................................495 PR1........................................................................................................................................................................495 PR10......................................................................................................................................................................495 PR11.........................
PST0130.................................................................................................................................................................514 PST0131.................................................................................................................................................................514 PST0132.................................................................................................................................................................
PSU0046................................................................................................................................................................534 PSU0076................................................................................................................................................................535 PSU0077................................................................................................................................................................
PWR0101...............................................................................................................................................................553 PWR0102...............................................................................................................................................................553 PWR0103...............................................................................................................................................................
36 RAC Event Messages...........................................................................................................571 RAC001..................................................................................................................................................................571 RAC002..................................................................................................................................................................571 RAC003..............................
RAC0136................................................................................................................................................................587 RAC0137................................................................................................................................................................588 RAC0138................................................................................................................................................................
RAC0218................................................................................................................................................................605 RAC0219................................................................................................................................................................605 RAC022..................................................................................................................................................................
RAC0261................................................................................................................................................................622 RAC0262................................................................................................................................................................622 RAC0263................................................................................................................................................................
RAC0304................................................................................................................................................................639 RAC031..................................................................................................................................................................640 RAC032..................................................................................................................................................................
RAC0708................................................................................................................................................................657 RAC0709................................................................................................................................................................657 RAC0710................................................................................................................................................................
RDU0015................................................................................................................................................................675 38 RED Event Messages............................................................................................................677 RED000..................................................................................................................................................................677 RED001.............................
41 RFM Event Messages...........................................................................................................695 RFM1018................................................................................................................................................................695 RFM1019................................................................................................................................................................695 RFM1020...............................
SEC0016.................................................................................................................................................................712 SEC0017.................................................................................................................................................................712 SEC0018.................................................................................................................................................................
SEL1204.................................................................................................................................................................729 SEL1205.................................................................................................................................................................730 SEL1206.................................................................................................................................................................
STOR007................................................................................................................................................................746 STOR009................................................................................................................................................................747 STOR010................................................................................................................................................................
STOR041................................................................................................................................................................764 STOR042................................................................................................................................................................764 STOR043................................................................................................................................................................
SUP0104................................................................................................................................................................781 SUP0105................................................................................................................................................................782 SUP0106................................................................................................................................................................
SUP0501................................................................................................................................................................798 SUP0502................................................................................................................................................................799 SUP0503................................................................................................................................................................
SWC0006...............................................................................................................................................................817 SWC0007...............................................................................................................................................................818 SWC0008...............................................................................................................................................................
SWC0115...............................................................................................................................................................835 SWC0116...............................................................................................................................................................835 SWC0117...............................................................................................................................................................
SWC0157...............................................................................................................................................................852 SWC0158...............................................................................................................................................................852 SWC0159...............................................................................................................................................................
SWC0238...............................................................................................................................................................869 SWC0239...............................................................................................................................................................869 SWC0240...............................................................................................................................................................
SWC0280...............................................................................................................................................................886 SWC0281...............................................................................................................................................................886 SWC0282...............................................................................................................................................................
SWC0322...............................................................................................................................................................903 SWC0323...............................................................................................................................................................903 SWC0324...............................................................................................................................................................
SYS015..................................................................................................................................................................921 SYS016..................................................................................................................................................................921 SYS017..................................................................................................................................................................
TMP0125...............................................................................................................................................................940 TMP0126...............................................................................................................................................................941 TMP0127...............................................................................................................................................................
UEFI0007................................................................................................................................................................960 UEFI0008................................................................................................................................................................960 UEFI0009................................................................................................................................................................
VDR17....................................................................................................................................................................978 VDR18....................................................................................................................................................................979 VDR19.................................................................................................................................................................
VDR55....................................................................................................................................................................998 VDR56....................................................................................................................................................................999 VDR57.................................................................................................................................................................
58 VLT Event Messages..........................................................................................................1019 VLT0100...............................................................................................................................................................1019 VLT0101...............................................................................................................................................................1019 VLT0102...............................
VLT0234...............................................................................................................................................................1040 VLT0235...............................................................................................................................................................1040 VLT0300...............................................................................................................................................................
1 Introduction The Event Message Reference contains the error and event information generated by firmware and other agents that monitor system components. These events might be logged, presented to the user on one of the system management consoles, or both logged and displayed. Each event consists of the following fields: Message ID Message The unique alphanumeric identifier for the event.
Initial Default Event messages result in event actions such as logging, SNMP, or email alerts. Generally, the event actions are configurable using the Dell iDRAC event action filtering feature. This item describes the initial default and possible event actions for the message. Event Action Filter Describes additional configurable actions that are available for the event action for this message.
2 AMP Event Messages AMP0300 The system board arg1 current is less than the lower warning threshold. Message Arguments – Detailed Description arg1 = name None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes. Category System Health SubCategory AMP = Amperage Severity Severity 2 (Warning) Trap/EventID 2178 LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0302 The system board arg1 current is greater than the upper warning threshold. Message Arguments – Detailed Description arg1 = name Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
LCD Message System board current is outside of range. Contact Support Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0304 The system board arg1 current is outside of range. Message Arguments – Detailed Description arg1 = name Product documentation contains information on correct configuration.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE AMP0306 Disk drive bay arg1 current is less than the lower warning threshold. Message Arguments – Detailed Description arg1 = name None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0308 Disk drive bay arg1 current is greater than the upper warning threshold. Message Arguments – Detailed Description arg1 = name Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0310 Disk drive bay arg1 current is outside of range. Message Arguments – Detailed Description arg1 = name Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE AMP0312 Message System level current is less than the lower warning threshold. Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
AMP0314 Message System level current is greater than the upper warning threshold. Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded. Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
AMP0316 Message System level current is outside of range. Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded. Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes.
Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes Category System Health SubCategory AMP = Amperage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE AMP0321 Message Chassis power level current is greater than the upper critical threshold. Detailed Description Product documentation contains information on correct configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE AMP0323 Message Chassis power level current is within range. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory AMP = Amperage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
3 ASR Event Messages ASR0000 Message The watchdog timer expired. Detailed Description The operating system or potentially an application failed to communicate to the baseboard management controller (BMC) within the timeout period. Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE ASR0002 Message The watchdog timer powered off the system. Detailed Description The operating system or an application failed to communicate to the baseboard management controller (BMC). The system powered off per the configured setting.
ASR0008 Message The watchdog timer interrupt was initiated. Detailed Description The operating system or an application failed to communicate to the baseboard management controller (BMC) within the timeout period. The BMC invoked a system interrupt. (IPMI sensor type code 23h - offset 00h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
Detailed Description The operating system or an application failed to communicate to the system board within the timeout period. The system was reset per the configured setting. (IPMI sensor type code 23h offset 01h event 3:0 - 2h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
Detailed Description The operating system or an application failed to communicate within the timeout period. The system was shutdown. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events. Category System Health SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) Trap/EventID 2233 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Check the operating system, application, hardware, and system event log for exception events. Category System Health SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) Trap/EventID 2233 LCD Message No LCD message display defined. Initial Default.
SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) Trap/EventID 2233 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE ASR0107 Message The OS watchdog timer pre-timeout interrupt was initiated.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE 78 FALSE FALSE
4 BAR Event Messages BAR001 Message Export System Profile requested. Detailed Description A system profile export has been requested. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description The Backup partition is being created for storing the backup file Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR006 Message Finalizing Backup file. Detailed Description The system profile backup file is being finalized and closed. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Verify the request parameters and retry. Check passphrase for rule validity. NOTE: A valid passphrase contains 8 to 32 characters. It must include a combination of uppercase and lowercase letters, numbers, and symbols without spaces. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR011 Message Unable to collect Hardware Inventory information. Detailed Description Hardware Inventory data collection and export has failed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR013 Message Host System Shutdown unsuccessful. Detailed Description The request to shut the Host system down has failed. Recommended Response Action Reboot the Integrated Remote Access Controller and retry the operation.
Detailed Description The Backup file information was not properly processed and the operation cannot continue. This can be due to resource constraints within the processing environment. If the network share is read only, this error will be thrown also. Recommended Response Action If this is backup to network share, check to make sure network share is read/write accessible. Reboot the Integrated Remote Access Controller and retry the operation.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR018 Message Backup file validation completed. Detailed Description A system profile backup file validation request has completed. Recommended Response Action No response action is required.
Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR021 Message Insufficient space on network share.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR023 Message Starting component updates. Detailed Description The process is entering the component update phase of the restore operation. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR026 Message Restoring Component Configuration. Detailed Description The configuration is being set for each component.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR028 Message Host System Component Restore completed with errors, shutting down Host System. Detailed Description The component restoration on the host system has completed, but there were errors. The Host System will shutdown.
Detailed Description The import system profile is complete. iDRAC restarts to complete restore. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR033 Message Unable to Restore Lifecycle Controller data. Detailed Description Lifecycle Controller data import has failed. Recommended Response Action 1. Download and apply the Dell Update Package for the Unified Server Configurator (USC). 2. Run System Services to update the database if CSIOR is not enabled. 3.
BAR035 Message Unable to Restore Integrated Remote Access Controller configuration. Detailed Description The Integrated Remote Access Controller (iDRAC) Configuration import has failed. Recommended Response Action Manually reset the Integrated Remote Access Controller (iDRAC) configuration. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR038 Message Cancel. Detailed Description Cancel the operation in progress. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR040 Message Unable to access vFlash. Detailed Description Access to the vFlash Card is not possible, or has been denied. Recommended Response Action Make sure the vFlash is enabled, not write protected, and initialized. Then try the operation again.
Recommended Response Action Wait for the other operation to release the resources, as indicated by the System Services option presence and try the operation again. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR045 Message Powering down the Host System for Integrated Remote Access Controller Restore. Detailed Description The host system is powering down to facilitate the import of the Integrated Remote Access Controller system profile. Recommended Response Action No response action is required.
BAR047 Message System Profile operation canceled by user. Detailed Description The System Profile operation was canceled as part of a clean up operation performed during a restart of the Integrated Remote Access Controller. Recommended Response Action Resubmit the System Profile operation. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action As indicated by the job status, wait for restore to complete. After the status displays Complete or Failed, wait for a few minutes for the Integrated Remote Access Controller (iDRAC) to restart. After restart, power on the Host System using iDRAC. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR052 Firmware update cannot be performed for Device: arg1 Message Arguments – arg1 = device name Detailed Description The required device firmware was not found, and the update will not occur.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR054 Message System Reset or System Services Canceled, System Profile Failure Recovery unsuccessful. Detailed Description The attempt to clean up after a failed Backup/Restore of a system profile operation has failed. The System Services related operations may not execute as expected until the system is properly cleaned.
BAR056 Component Configuration Restored on Device : arg1 Message Arguments – arg1 = device name Detailed Description The configuration import was successful for the specified device. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description The system profile export/import network destination is being checked for access. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR061 Message Collecting System Information. Detailed Description Collecting system information and placing it in the export backup file. The information collected includes, but is not limited to, the System Model and Service Tag. Recommended Response Action No response action is required.
Detailed Description Collecting the Lifecycle Controller firmware images and placing them in the export backup file. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR066 Message vFlash media not enabled. Detailed Description The system profile export destination is not enabled. Recommended Response Action Enable the vFlash media and retry the operation.
Recommended Response Action Obtain, insert, enable and initialize supported vFlash media. Then retry the operation Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR069 Message Insufficient space on vFlash media.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR071 Message CIFS Destination access denied. Detailed Description Access to the CIFS export/import destination is not possible or has been denied. Recommended Response Action Verify that the input parameters are correct, connectivity exists to the destination end point, and retry the operation.
Recommended Response Action Enable and initialize the vFlash media and retry the export. If the error continues, try a new vFlash media or use the network share option(s). Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR076 Message Unable to collect the Configuration database. Detailed Description The collection and export of Lifecycle Controller Configuration Database failed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR078 Message Unable to collect the Integrated Remote Access Controller firmware. Detailed Description The collection and export of Integrated Remote Access Controller firmware failed. Recommended Response Action Apply the integrated remote access controller firmware, manually set the configuration attributes, and try the operation again.
Detailed Description Importing the Lifecycle Controller configuration database from the system profile backup file. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR083 Message Host System Model does not match the Backup file System Model information. Detailed Description System profile backup file validation failed because the host system model information does not match the value stored in the file.
BAR085 Message Unable to collect System Information for Import Backup file validation. Detailed Description The validation of the system profile backup file has failed. The retrieval of system information to validate the backup file has failed. Recommended Response Action Restart the remote access controller, and retry the operation. If the error continues, use the remote access controller firmware to try the operation again.
Detailed Description The system profile import of Lifecycle Controller firmware images has failed. Recommended Response Action Apply the Dell Update Package for this system. If the error continues, use the field service repair software to repair the Lifecycle Controller. Download all Dell Update Packages for USC, Diagnostics Driver Packs, and device firmware for all host system devices, install all packages and retry the operation.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR090 Message System Profile Backup requested. Detailed Description A request to create a System Profile Backup file has been made by the user of the Unified Server Configurator interface.
BAR092 Message Disconnect from NFS unsuccessful. Detailed Description The attempt to disconnect from the user supplied NFS location has failed. Recommended Response Action If this happens on a backup request, restart the Ingetrated Remote Acess Controller and try the operation again. If this is a restore request the Integrated Remote Access will be restarted during the execution of the request. Only restart the Integrated Remote Access Controller if it does not restart on its own.
Detailed Description The request to create a System Profile Backup file has failed as there is already a request in progress. Recommended Response Action If possible monitor the in progress job for completion and then retry the request. if that is not possible try clearing all jobs and try the request again. If that fails, restart the Integrated Remote Access controller and try the request again.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR097 Message USC incompatibility detected. Detailed Description The current USC software installed on the system does not have Backup and Restore feture support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR099 Message Collecting License data. Detailed Description License data is being collected and copied into the backup Server Profile. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR102 Message Unable to restore license data.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR104 Message Unable to collect system branding data. Detailed Description Cannot collect system branding data to copy to backup Server Profile. Recommended Response Action Retry the operation. If the issue continues, contact the service provider.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR107 Message vFlash media reader license not present. Detailed Description The vFlash media reader requires a license to function.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR109 Message OEMDRV partition is in use. Detailed Description The OEMDRV partition is mounted for performing operating system deployment use. This situation prevents the Export and Import Server Profile operation from continuing. Recommended Response Action Dismount the OEMDRV partition by selecting F10 during boot and retry the operation.
BAR111 Message Server Profile operation timed out. Detailed Description The Import or Export job has failed. The Import or Export operation timed-out while validating or transferring Server Profile data. Possible causes are loss of network connectivity, vFlash SD card access failure, or problems encountered with system power off and on. Recommended Response Action If the managed system does not turn off during Import, turn off the system and retry the operation.
5 BAT Event Messages BAT0000 Message The system board battery is low. Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the system board battery at the next service window. Category System Health SubCategory BAT = Battery Event Severity Severity 2 (Warning) Trap/EventID 2226 LCD Message No LCD message display defined. Initial Default.
BAT0002 Message The system board battery has failed. Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the system board battery. Category System Health SubCategory BAT = Battery Event Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message System board battery has failed. Check battery Initial Default.
Recommended Response Action Check the system board battery to confirm presence. Category System Health SubCategory BAT = Battery Event Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message System board battery is absent. Check battery Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE BAT0005 Message The storage battery is low.
Trap/EventID 2227 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT0007 Message The storage battery has failed. Detailed Description The PERC RAID controller battery may have failed because of thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT0009 Message The storage battery is absent. Detailed Description The PERC RAID controller battery may report absent due to disconnect or thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or reconnect the battery and cables.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE BAT0011 The storage battery for disk drive bay arg1 is operating normally. Message Arguments arg1 = bay – Detailed Description None Recommended Response Action Verify the battery installation, check the system logs for thermal related issues.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE BAT0013 The storage battery for disk drive bay arg1 is present. Message Arguments – arg1 = bay Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 2227 LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE BAT0015 The arg1 battery is low. Message Arguments – Detailed Description arg1 = name System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery at the next service window.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT0017 The arg1 battery has failed. Message Arguments – Detailed Description arg1 = name System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT0019 The arg1 battery is absent. Message Arguments – Detailed Description arg1 = name System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery to confirm presence.
Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1001 Battery on arg1 was replaced. Message Arguments – arg1 = controller name Detailed Description A controllers battery was replaced. Recommended Response Action No response action is required.
BAT1003 The battery on arg1 learn cycle has completed. Message Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1005 The battery on arg1 learn cycle has been postponed. Message Arguments arg1 = Controller name – Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
BAT1007 The battery on arg1 learn cycle will start in arg2 hours. Message Arguments – – arg1 = Controller name arg2 = arg Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
BAT1009 Write policy on arg1 was changed to Write Back. Message Arguments – arg1 = controller name Detailed Description The controller battery health has returned to normal. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default.
Arguments arg1 = Controller name – Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1014 arg1 battery charge in-progress. Message Arguments – Detailed Description arg1 = Controller name Diagnostic event for service to determine if there is an ambient temperature problem.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1016 The arg1 battery learn mode has changed to Auto. Message Arguments arg1 = Controller name – Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
BAT1018 Battery on arg1 is degraded. Message Arguments – arg1 = Controller name Detailed Description The temperature of the battery is high. This may be due to the battery being charged. Recommended Response Action If the battery is being charged, then charging the battery should be stopped until the battery cools down and charging should be resumed. If this is not case, then some other condition exists and should be investigated.
Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory BAT = Battery Event Severity Severity 2 (Warning) Trap/EventID 4274 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1025 arg1 is unable to recover cached data from the Battery Backup Unit (BBU).
Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1027 The battery on arg1 completed a charge cycle.
Severity Severity 2 (Warning) Trap/EventID 4274 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1029 The battery on arg1 can no longer recharge. Message Arguments – Detailed Description arg1 = controller name The controller battery cannot recharge.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1031 The battery temperature on arg1 is above normal. Message Arguments – Detailed Description arg1 = controller name The room temperature may be too hot. In addition, the system fan may be degraded or failed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1033 The battery on arg1 was removed. Message Arguments arg1 = controller name – Detailed Description The controller cannot communicate with the battery. Either the battery was removed, or the contact point between the controller and the battery is degraded.
Initial Default.
6 BIOS Event Messages BIOS001 Message The command was successful Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration SubCategory BIOS = BIOS Management Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
BIOS003 Message Missing required parameter. Refer to the inserted comment. Detailed Description An invalid number of arguments was passed to the method. Recommended Response Action Enter all the required command parameters. Check documentation and try again. \n Category Configuration SubCategory BIOS = BIOS Management Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory BIOS = BIOS Management Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS008 Message No pending data present to create a Configuration job Detailed Description No changes are available between the previous configuration and the current configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS010 Message Lifecycle Controller is not enabled, cannot create Configuration job. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS012 Message No pending data to delete. Detailed Description No changes to BIOS attribute data are available between the previous configuration and the current configuration. Recommended Response Action No response action is required.
BIOS014 Invalid AttributeValue for AttributeName: arg1 Message Arguments – arg1 = attribute name Detailed Description AttributeValue may be invalid because of the following causes: \n1. Length of new AttributeValue is not within minLength and maxLength \n2. Value of new AttributeValue is not within LowerBound and UpperBound \n3.
BIOS016 AttributeValue cannot be changed for disabled AttributeName arg1. Message Arguments – arg1 = attribute name Detailed Description A set attribute operation was attempted on a disabled attribute. Recommended Response Action No response action is required. Category Configuration SubCategory BIOS = BIOS Management Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Retry the operation with a BIOS password that conforms with system BIOS password requirements. Category Configuration SubCategory BIOS = BIOS Management Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS021 Message Cannot authenticate BIOS password.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS023 Message Cannot perform the operation due to an unknown error in iDRAC. Detailed Description An unrecoverable error occurred in the operation while communicating with iDRAC. An iDRAC reset or power cycle is recommended. Recommended Response Action Retry the operation.
BIOS025 Message Cannot set the BIOS password as the BIOS password status is locked. Detailed Description The status of the password is Locked in BIOS and must be set to Unlocked for the operation to succeed. Recommended Response Action Modify the status of the password in the BIOS setup from Locked to Unlocked and retry the operation. Category Configuration SubCategory BIOS = BIOS Management Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
7 BOOT Event Messages BOOT001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
BOOT003 Message Method not supported Detailed Description This operation is not supported on the current configuration. Recommended Response Action This operation is not supported on the current configuration, check documentation and try again Category Configuration SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BOOT006 Message Invalid Boot Source InstanceID Detailed Description One or more of the Boot Source instance IDs does not contain valid data.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BOOT008 Message Source argument contains more devices than are present on the system Detailed Description More source arguments were provided than are available for the impacted Boot Configuration.
BOOT010 Message Could not locate vFlash partition index Detailed Description The provided vFlash partition index could not be found on the system. Recommended Response Action Verify that a vFlash partition with the desired index exists on the System. Category Configuration SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BOOT013 Message Cannot make changes to non-active boot list Detailed Description The boot list is currently not active. Changes cannot be made to boot list that is not active.
BOOT015 Message Set operation successful for the boot partition. Detailed Description The boot partition configuration request was successful. An unattached vFlash partition was configured for one-time boot using the ChangeBootOrderByInstanceID method. The method creates a job (to attach the vFlash partition and set the partition for onetime boot. Recommended Response Action No response action is required.
BOOT017 Message Source argument does not support enable or disable mode Detailed Description The boot device(s) specified in the source argument used in the operation cannot be enabled or disabled. This behavior applies to BCV devices and one-time boot. Recommended Response Action Refer to the documentation on validity of operation for the boot device specified. Category Configuration SubCategory BOOT = BOOT Control Severity Severity 2 (Warning) LCD Message No LCD message display defined.
8 CBL Event Messages CBL0001 Backplane arg1 power cable disconnected. Message Arguments – Detailed Description arg1 = Bay ID A backplane signal cable was detected, but the accompanying power cable was not present. Recommended Response Action Check backplane configuration. Re-connect cable. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE TRUE FALSE FALSE FALSE FALSE CBL0003 Backplane arg1 connector arg2 disconnected. No cable detected. Message Arguments – – Detailed Description arg1 = Bay ID arg2 = Connector Name None Recommended Response Action Check backplane configuration. Re-connect cable.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE TRUE FALSE FALSE FALSE FALSE CBL0005 Backplane arg1 connector arg2 incorrectly connected to motherboard SATA controller. Message Arguments – – Detailed Description arg1 = Bay ID arg2 = Connector Name None Recommended Response Action Check backplane configuration. Re-connect cable.
LCD Message No LCD message display defined. Initial Default.
9 CPU Event Messages CPU0000 CPU arg1 has an internal error (IERR). Message Arguments – Detailed Description arg1 = number System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU has a thermal trip. Check CPU heat sink Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE CPU0002 CPU arg1 has failed the built-in self-test (BIST). Message Arguments – Detailed Description arg1 = number None Recommended Response Action 1) Turn system off and remove input power for one minute.
contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory CPU = Processor Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE CPU0004 CPU arg1 failed to initialize.
Recommended Response Action Review product documentation for supported CPU configurations. Category System Health SubCategory CPU = Processor Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU configuration is unsupported. Check CPU or BIOS revision Initial Default.
Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0008 CPU arg1 is disabled. Message Arguments – arg1 = number Detailed Description System is unable to boot or may run in a degraded state.
Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0010 CPU arg1 is throttled. Message Arguments – arg1 = number Detailed Description The CPU is throttled due to thermal or power conditions. Recommended Response Action Review system logs for power or thermal exceptions.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0021 CPU arg1 is configured correctly. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default.
CPU0025 CPU arg1 terminator is absent. Message Arguments – arg1 = number Detailed Description System is unable to boot or may run in a degraded state. Recommended Response Action Check presence and reinstall the terminator. Category System Health SubCategory CPU = Processor Severity Severity 2 (Warning) Trap/EventID 2242 LCD Message No LCD message display defined. Initial Default.
CPU0701 CPU arg1 protocol error detected. Message Arguments arg1 = number – Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action 1) Check system and operating system logs for exceptions. If no exceptions are found continue. 2) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 3) Make sure the processor is seated correctly.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE CPU0703 Message CPU bus initialization error detected. Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action 1) Check system and operating system logs for exceptions. If no exceptions are found continue. 2) Turn system off and remove input power for one minute.
LCD Message CPU machine check error detected. Power cycle system Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE CPU0800 CPU arg1 voltage regulator module is present. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0802 A predictive failure detected on CPU arg1 voltage regulator module. Message Arguments – arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute.
LCD Message Lost power input for CPU voltage regulator module. Reseat module Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0804 The power input for CPU arg1 voltage regulator module is outside of range. Message Arguments – arg1 = number Detailed Description System performance may be degraded or the system may fail to operate.
SubCategory CPU = Processor Severity Severity 2 (Warning) Trap/EventID 2242 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0806 CPU arg1 voltage regulator module is incorrectly configure. Message Arguments – Detailed Description arg1 = number System performance may be degraded or the system may fail to operate.
LCD Message CPU voltage regulator module absent. Check module Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0817 CPU arg1 voltage regulator module is operating normally. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0822 CPU arg1 voltage regulator module is configured correctly. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined.
10 CPUA Event Messages CPUA0023 CPU arg1 is absent Message Arguments arg1 = number – Detailed Description None Recommended Response Action Verify processor installation. If present, reseat the processor. Category System Health SubCategory CPUA = Proc Absent Severity Severity 1 (Critical) Trap/EventID 2457 LCD Message CPU is absent. Check CPU Initial Default.
11 CTL Event Messages CTL1 arg1 log file entry: arg2 Message Arguments – – Detailed Description arg1 = controller name arg2 = message The text for this message is generated by the controller and varies depending on the situation and object. These are events retrieved from the controller when iDRAC storage monitoring was not running. Recommended Response Action No response action is required.
Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL11 Configuration on arg1 was reset. Message Arguments – arg1 = controller name Detailed Description A user operation to reset the controller configuration was performed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL13 The arg1 cache has been discarded. Message Arguments arg1 = Controller name – Detailed Description The controller has flushed the cache and all data in the cache has been lost. This may occur when the system has memory or battery problems that cause the controller to distrust the cache.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL16 None of the arg1 properties are set. Message Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined.
CTL18 Load Balance and Auto Copyback on Predictive Failure has changed for arg1. Message Arguments arg1 = Controller name – Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description You have changed the controller rebuild rate. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL22 Load Balance has changed for arg1. Message Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL24 Abort CC on Error and Auto Copyback on Predictive Failure has changed for arg1. Message Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
CTL26 Copyback and Abort CC on Error has changed for arg1. Message Arguments arg1 = Controller name – Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default.
Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL30 The Check Consistency rate has changed for arg1. Message Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL32 Abort CC on Error is modified for arg1. Message Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command.
CTL34 A foreign configuration was cleared on arg1. Message Arguments – arg1 = controller name Detailed Description This is the result of a user operation. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments arg1 = Controller name – Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL39 The arg1 reconstruct rate has changed.
SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL40 Multi-bit ECC error on arg1 DIMM. Message Arguments – arg1 = Controller name Detailed Description An error involving multiple bits has been encountered during a read or write operation.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL42 Enclosure Management Module (EMM) hot plug is not supported on arg1.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Replace the Dual In-line Memory Module (DIMM) to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. Refer to hardware documentation for information on replacing the DIMM. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default.
Detailed Description The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may occur. The DIMM must be replaced immediately. Recommended Response Action Replace the DIMM immediately. The DIMM is a part of the controller battery pack. Refer to your hardware documentation for information on replacing the DIMM. Category Storage SubCategory CTL = Storage Contr Severity Severity 1 (Critical) Trap/EventID 4329 LCD Message No LCD message display defined. Initial Default.
CTL49 The NVRAM has corrupted data on arg1. Message Arguments – arg1 = Controller name Detailed Description The NVRAM has corrupted data. This may occur after a power surge, a battery failure, or for other reasons. The controller is reinitializing the NVRAM. Recommended Response Action No response action is required as the controller is taking the required corrective action. However, If this message is generated often (such as during each reboot), then replace the controller.
CTL50 The arg1 NVRAM has corrupt data. Message Arguments – arg1 = Controller name Detailed Description The NVRAM has corrupt data. The controller is unable to correct the situation. Recommended Response Action Replace the controller. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default.
CTL52 arg1 SAS port report: arg2 Message Arguments – – Detailed Description arg1 = Controller name arg2 = args This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default.
Arguments – – Detailed Description arg1 = Controller name arg2 = args This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
CTL56 arg1 event log: arg2 Message Arguments arg1 = Controller name arg2 = args – – Detailed Description The text for this alert is generated by the controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running. Recommended Response Action See the hardware documentation for more information.
CTL58 arg1 SAS SMP communications error arg2 Message Arguments arg1 = Controller name arg2 = args – – Detailed Description The text for this alert is generated by the firmware and can vary depending on the situation. The reference to SMP in this text refers to SAS Management Protocol. Recommended Response Action There may be a SAS topology error. See the hardware documentation for information on correct SAS topology configurations.
Category Storage SubCategory CTL = Storage Contr Severity Severity 1 (Critical) Trap/EventID 4329 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL6 Bad block sense error from arg1 Message Arguments – Detailed Description arg1 = Controller name A portion of a physical disk is damaged.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL61 Physical disks found missing from configuration during boot time on arg1.
SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL63 Previous configuration was found completely missing during time boot on arg1.
SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL65 Attempted to import Unsupported Virtual Disk type RAIDarg1 on arg2. Message Arguments – – arg1 = args arg2 = Controller name Detailed Description This alert is provided for informational purposes.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL67 Attempted to import Virtual Disk with missing span on arg1. Message Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
CTL69 Attempted to import virtual disk with outdated physical disk information on arg1. Message Arguments arg1 = Controller name – Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL73 Message Foreign configuration is imported only partially. Some configurations failed to import on arg1.
SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL75 Preserved cache discarded on arg1. Message Arguments – Detailed Description arg1 = controller name The controller cache was discarded by the user.
Trap/EventID 4329 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL77 Flash of new firmware image(s) completed on arg1 Message Arguments – arg1 = Controller Name Detailed Description This alert message occurs if controller firmware is flashed successfully.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL8 Bad block extended sense error on arg1. Message Arguments – Detailed Description arg1 = Controller name A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE 234 FALSE FALSE
12 DH Event Messages DH001 Message Resource needed to perform the operation is unavailable. Detailed Description Resource temporarily unavailable Recommended Response Action Try again. If the error persists, use RACADM command racreset to clear the issue. Category Configuration SubCategory DH = Cert Mgmt Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Detailed Description Service Tag Missing Recommended Response Action Try again. If the error persists, use RACADM command racreset to clear the issue. Category Configuration SubCategory DH = Cert Mgmt Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DH006 Message Not the right passphrase for the private key (need to re-write) Detailed Description Invalid Passphrase Recommended Response Action Validate that the certificate parameter matches the certificate contents; the certificate can be validated using Openssl tools.
Detailed Description Failed to save client certificate. Recommended Response Action Try again. If the error persists, use RACADM command racresetcfg to clear the issue. Category Configuration SubCategory DH = Cert Mgmt Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
13 DIS Event Messages DIS001 Message Auto Discovery feature not licensed. Detailed Description Auto Discovery starts automatically, but was unable to find a valid license. Once you have obtained a valid license and installed it, restart. Recommended Response Action Follow service providers instructions to enable the license. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
DIS003 Message Auto Discovery process started. Detailed Description Auto Discovery process will try to connect to a Provisioning Server over the next 24 hours. Recommended Response Action No response action is required. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description Message was sent successfully from Auto Discovery to Provisioning Server to request certificate. Recommended Response Action No response action is required. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DIS008 Notification of iDRAC IP address changed to arg1 from arg2 sent to Provisioning Server. Message Arguments arg1 = new IP address arg2 = old IP address – – Detailed Description iDRAC IP address change in progress with Provisioning Server. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DIS010 Auto Discovery LCD display message: arg1 Message Arguments – arg1 = progress message Detailed Description The Auto Discovery process has encountered a problem.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DIS012 Message Auto Discovery client using factory signed client certificate. Detailed Description Factory signed client certificate is being used. Auto Discovery client is using this certificate for the SSL connection with the Provisioning Server. Recommended Response Action No response action is required.
Detailed Description Auto Discovery client is using the customer provided Certificate Authority certificate to authenticate the Provisioning Server for the SSL connection. Recommended Response Action No response action is required. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default.
14 DKM Event Messages DKM0001 arg1 key added for slot arg2 of user arg3. Message Arguments arg1 = Security_Key arg2 = Slot_num arg3 = Username – – – Detailed Description %s key added for slot %d of user %d. Recommended Response Action No response action is required. Category Audit SubCategory DKM = Dell Key Mngr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DKM0003 arg1 key deleted for slot arg2 of user arg3. Message Arguments – – – arg1 = Security_Key arg2 = Slot_num arg3 = Username Detailed Description The PKSSH security key was deleted for listed slot number for the user Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DKM1000 Message A network problem detected. Cannot contact key management server. Detailed Description None Recommended Response Action Check for network connectivity. Review network, server, and client configuration.
Category System Health SubCategory DKM = Dell Key Mngr Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DKM1004 Message The key management server received a bad request. Detailed Description None Recommended Response Action Check for network connectivity.
15 ENC Event Messages ENC1 An Enclosure Management Module (EMM) was inserted into arg1. Message Arguments – arg1 = enclosure name Detailed Description This message is generated after an EMM is inserted into an enclosure. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) Trap/EventID 4339 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC11 The arg1 service tag was changed. Message Arguments – Detailed Description arg1 = Enclosure Name An enclosure service tag was changed. In most circumstances, this service tag should only be changed by Dell support. Recommended Response Action Ensure that the service tag was changed under authorized circumstances.
ENC13 Unsupported configuration detected on arg1. arg2 arg3 Message Arguments arg1 = Enclosure Name arg2 = EMM0 1 arg3 = EMM1 2 – – – Detailed Description An unsupported configuration was detected. The SCSI rate of the Enclosure Management Modules (EMMs) are not the same. Recommended Response Action Replace one of the EMMs with the matching SCSI rate EMM. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC15 An enclosure blink operation has initiated on arg1. Message Arguments – arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
ENC17 An Enclosure Management Module (EMM) has been discovered on arg1. Message Arguments – arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
ENC19 The Enclosure Management Module (EMM) has failed in arg1. Message Arguments arg1 = Enclosure Name – Detailed Description An Enclosure Management Module (EMM) has failed. The failure may be caused by a loss of power to the EMM. The EMM self test may also have identified a failure. There may also be a firmware problem or a multi-bit error. Recommended Response Action Reseat the Enclosure Management Module (EMM). See the storage hardware documentation for information on replacing the EMM.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC20 arg1 has been inserted. Message Arguments – arg1 = Enclosure element name Detailed Description This message is generated after a device was inserted into enclosure. Recommended Response Action No response action is required.
ENC22 The arg1 has a bad sensor arg2. Message Arguments – – Detailed Description arg1 = Enclosure Name arg2 = args The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and so on. Recommended Response Action Refer to the storage hardware documentation for more information. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 2 (Warning) Trap/EventID 4338 LCD Message No LCD message display defined. Initial Default.
ENC24 Communication with arg1 is intermittent. Message Arguments arg1 = enclosure name – Detailed Description The controller is not receiving a consistent response from the enclosure.There could be a firmware problem or an invalid cabling configuration.If the cables are too long, they degrade the signal. Recommended Response Action Power down all enclosures attached to the system and reboot . If the problem persists, upgrade the firmware to the latest supported version.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC26 arg1 is not responding. Message Arguments – arg1 = enclosure name Detailed Description The enclosure or an enclosure component is in a Failed or Degraded state. It is not responding to storage management commands or there is a connectivity problem between the controller and enclosure.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC28 Message Enclosure Management Module (EMM) firmware version mismatch detected in arg1.arg2 arg3. Arguments – – – arg1 = enclosure name arg2 = EMM 0 version arg3 = EMM 1 version Detailed Description The firmware on the EMM modules is not the same version. Both modules must have the same firmware version.
Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC3 arg1 is shutdown. Message Arguments arg1 = Enclosure Name – Detailed Description The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature range. Recommended Response Action Check for factors that may cause overheating or excessive cooling.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC31 Firmware download on arg1 has failed. Message Arguments arg1 = Enclosure Name – Detailed Description The system was unable to download firmware to the enclosure. The controller may have lost communication with the enclosure. There may have been problems with the data transfer or the download media may be corrupt.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC33 Redundancy on arg1 is normal. Message Arguments arg1 = Enclosure Name – Detailed Description Data redundancy has been restored to an enclosure that previously suffered a loss of redundancy. Recommended Response Action This alert is provided for informational purposes.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC4 arg1 firmware mismatch. Message Arguments arg1 = Enclosure Name – Detailed Description The firmware on the EMM modules is not the same version. It is required that both modules have the same version of the firmware. This alert may be caused when you attempt to insert an EMM module that has a different firmware version than an existing module.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC5 Redundancy on arg1 is degraded Message Arguments arg1 = Enclosure Name – Detailed Description One or more of the enclosure components has failed. For example, a fan or power supply may have failed. Although the enclosure is currently operational, the failure of additional components could cause the enclosure to fail.
Verify that the controller has the supported driver and firmware versions installed and that each Enclosure Management Modules (EMMs) are running the same version of supported firmware. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC9 The arg1 asset tag was changed. Message Arguments – Detailed Description arg1 = Enclosure Name You have changed the enclosure asset tag. This alert is provided for informational purposes.
16 FAN Event Messages FAN0000 Fan arg1 RPM is less than the lower warning threshold. Message Arguments – Detailed Description arg1 = number The fan is not performing optimally. The fan may be installed improperly or may be failing. Recommended Response Action Remove and re-install the fan at the next scheduled service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Trap/EventID 2153 LCD Message Fan RPM is outside of range. Check fan. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE FAN0002 Fan arg1 RPM is greater than the upper warning threshold. Message Arguments – Detailed Description arg1 = number The fan is not performing optimally. The fan may be installed improperly or may be failing.
Severity Severity 1 (Critical) Trap/EventID 2153 LCD Message Fan RPM is outside of range. Check fan. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE FAN0004 Fan arg1 RPM is outside of range. Message Arguments – Detailed Description arg1 = number The fan is not performing optimally. The fan may be installed improperly or may be failing.
Trap/EventID 2155 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE FAN0006 Fan arg1 is removed. Message Arguments – arg1 = number Detailed Description The fan may be required for optimal performance. Recommended Response Action If unintentional, install a fan.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE FAN0008 Fan arg1 is present. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory FAN = Fan Event Severity Severity 3 (Informational) Trap/EventID 2155 LCD Message No LCD message display defined. Initial Default.
FAN0010 Fan arg1 is disabled. Message Arguments – arg1 = number Detailed Description The fan may be required for optimal performance. Recommended Response Action No response action is required. Category System Health SubCategory FAN = Fan Event Severity Severity 2 (Warning) Trap/EventID 2154 LCD Message No LCD message display defined. Initial Default.
FAN1000 arg1 was removed. Message Arguments – Detailed Description arg1 = Fan Sensor Name An enclosure fan was removed and the enclosure is no longer functioning in optimal condition.. Recommended Response Action Re-insert the fan into the enclosure. Contact technical support if the issue persists. Category Storage SubCategory FAN = Fan Event Severity Severity 1 (Critical) Trap/EventID 4201 LCD Message No LCD message display defined. Initial Default.
17 FSD Event Messages FSD000 Debug authorized by customer; debugcaps: arg1, was authorized by: arg2, at arg3 for the period: arg4 to arg5. Message Arguments – arg1 = DebugCaps – arg2 = iDRAC User – arg3 = unblock time – arg4 = start time – arg5 = end time Detailed Description The customer has authorized the specified debug capabilities on this iDRAC. (This should occur in response to a request from Dell tech support.
Detailed Description Dell has authorized the specified debug capabilities. Each debug capability represents a certain action Dell engineers can perform to debug iDRAC. Recommended Response Action No response action is required. Category Audit SubCategory FSD=Debug Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD OS Log Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TRUE 279
18 HWC Event Messages HWC0001 Message Requested operation cannot be completed. No response from iDRAC. Detailed Description The error is caused due to iDRAC failure. For more information about the failure, see the Lifecycle Log from iDRAC. Recommended Response Action 1.) Turn off the system and disconnect the power cord. 2.) Wait five seconds. 3.) Reconnect the power cord and turn on the system.
HWC0003 Message vFlash Initialization is successful. Detailed Description vFlash SD card media Initialized successfully. Recommended Response Action No response action is required. Category Configuration SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action 1.) Turn off the system and disconnect the power cord. 2.) Wait five seconds. 3.) Reconnect the power cord and turn on the system. Category Configuration SubCategory HWC = Hardware Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC1000 The arg1 is present. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC1002 The arg1 is disabled. Message Arguments – arg1 = name Detailed Description None Recommended Response Action If device disabled unexpectedly, re-enable device. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
HWC1004 Message The storage adapter is present. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC1007 Message The storage adapter is enabled. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC1009 Message The backplane is absent. Detailed Description The backplane may be necessary for proper operation. System functionality may be degraded. Recommended Response Action If removal was unintended, check presence, then re-install or reconnect.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC1012 Message The USB cable is present.
LCD Message The USB cable is absent. Check cable Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC1014 The mezzanine card arg1 is present. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC1100 The arg1 was installed in slot arg2. Message Arguments – – arg1 = name arg2 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
HWC2000 The arg1 cable or interconnect is connected. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
HWC2002 The storage arg1 cable or interconnect is connected. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
HWC2004 The system board arg1 cable or interconnect is connected. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
HWC2006 The arg1 is not installed correctly. Message Arguments – Detailed Description arg1 = name The device may be necessary for proper operation. System functionality may be degraded. Recommended Response Action Check presence, then re-install or reconnect. Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message is not installed correctly. Check connection Initial Default.
HWC2008 A fabric mismatch detected for mezzanine card arg1. Message Arguments – arg1 = number Detailed Description The fabric type for the IOM and mezzanine cards must match. Once an IOM or mezzanine card is inserted into the chassis, the fabric type is then set for the CMC and the CMC will ensure that all subsequent IOMs and mezzanine cards match. Recommended Response Action Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
HWC2010 Message The riser board cable or interconnect is connected. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
Detailed Description The removed device may be necessary for proper operation. System functionality may be degraded. Recommended Response Action If removal was unintended, check presence, then re-install or reconnect Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC3003 Server arg1 was inserted. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC3005 IO module arg1 was inserted. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
HWC4001 Message A hardware incompatibility was corrected between BMC/iDRAC firmware and CPU. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC4010 Hardware successfully updated for mezzanine card arg1.
Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC4012 Message Hardware successfully updated for embedded NIC. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC4014 Message Link Tuning data successfully updated. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
HWC4016 Hardware incompatibility detected with mezzanine card arg1. Message Arguments – Detailed Description arg1 = number The system has detected a mezzanine card that is not supported on this system. Recommended Response Action 1) Review system documentation for supported mezzanine cards. 2) Replace mezzanine card with a supported mezzanine card.
Arguments – arg1 = name Detailed Description None Recommended Response Action If unexpected, check presence, then re-install or reconnect. Category System Health SubCategory HWC = Hardware Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5004 A link tuning failure detected on arg1.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5008 Console is not available for the arg1. Message Arguments – Detailed Description arg1 = name None Recommended Response Action Contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5012 On screen display (OSCAR) is not functional for the arg1. Message Arguments – Detailed Description arg1 = name None Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
HWC5030 IO module arg1 is online. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – arg1 = number Detailed Description The fabric type for IOMs on the same chassis fabric must match. Recommended Response Action Check chassis fabric type in CMC GUI and compare to the type of both IOMs. Category System Health SubCategory HWC = Hardware Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory HWC = Hardware Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5036 A failure is detected on IO module arg1. Message Arguments – Detailed Description arg1 = number The IOM module performance may be impact. Recommended Response Action Contact technical support.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC6001 The arg1 controller is online. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
HWC6003 The arg1 controller is booting. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC7000 Server arg1 health changed to a normal state.
SubCategory HWC = Hardware Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC7004 Server arg1 health changed to a critical state from either a normal or warning state.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC7008 Server arg1 health changed to a warning state from more severe state. Message Arguments – arg1 = number Detailed Description Server health changed to a warning state from more severe state. Recommended Response Action Review System Log or front panel for additional information.
HWC7012 Server arg1 health changed to a non-recoverable state. Message Arguments – arg1 = number Detailed Description Server health changed to a non-recoverable state. Recommended Response Action Review System Log or front panel for additional information. Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
19 IPA Event Messages IPA0001 Message Invalid NIC IP address parameter specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the valid IP Address. Category Audit SubCategory IPA = DRAC IP Change Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the appropriate subnet mask. Category Audit SubCategory IPA = DRAC IP Change Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE IPA0004 Message Invalid gateway address specified.
20 JCP Event Messages JCP001 Message Task successfully scheduled. Detailed Description The UEFI automated task related to the job was successfully scheduled. Recommended Response Action No response action is required. Category Configuration SubCategory JCP = Job Control Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
JCP003 Message Job failed. Detailed Description An iDRAC reboot caused a failure of the scheduled jobs. Recommended Response Action Retry the update and schedule the update job. Category Configuration SubCategory JCP = Job Control Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory JCP = Job Control Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP006 Message Invalid job attribute. Detailed Description One or more of the input values for creating a job are invalid or an internal error has occurred when scheduling the job.
JCP008 Message Job completed with errors. Detailed Description Multiple attributes were set in the operation but some set attribute actions were not successful. For example, setting an attribute that is not valid for the component being configured, Recommended Response Action Examine the results of the configuration job in the Lifecycle Log for the source of the errors. Modify the settings as necessary and resubmit the job.
Detailed Description The method invoked was successful. Recommended Response Action No response action is required. Category Configuration SubCategory JCP = Job Control Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory JCP = Job Control Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP013 Missing parameter(s) arg1 Message Arguments – Detailed Description arg1 = parameters One or more required input parameters needed for the operation are missing.
SubCategory JCP = Job Control Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP015 Message A running job cannot be deleted. Detailed Description The job is currently executing and cannot be deleted. The job needs to finish running, whether successful or not, before it can be deleted.
JCP017 Message Job creation request unsuccessful. Maximum number of jobs reached. Detailed Description The current job count has reached the maximum value supported. No more jobs are created until the number of jobs on the system is reduced. Completed jobs are automatically deleted if they are older than the DeleteOnCompletionTimeout setting. Recommended Response Action Perform one of the following to reduce the job count: 1) Delete one or more jobs and retry the operation.
JCP019 Message Cannot create new jobs until the existing Import System Profile job is completed or cancelled. Detailed Description A new job cannot be created until the existing Import Server Profile job is complete or deleted. Only one Import Server Profile job can be running at any given time. Recommended Response Action Perform one of the following: 1) Retry the operation after the Import Server Profile job is complete. 2) Delete the scheduled Import Server Profile job and retry the operation.
Category Configuration SubCategory JCP = Job Control Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP022 Invalid Job ID arg1 for scheduling or deletion operation.
SubCategory JCP = Job Control Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP024 Message Lifecycle Controller is in use. This job starts when Lifecycle Controller is available.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP026 Message Update packages are being downloaded. This job resumes when the downloads are completed. Detailed Description Update packages are being downloaded for other jobs initiated on this system. This job resumes when the downloads complete. Recommended Response Action No response action is required.
21 LC Event Messages LC001 Message Command successful. Detailed Description The command completed successfully. Recommended Response Action No response action is required. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description An error occurred while trying to set the firmware update mode. Recommended Response Action Verify that the firmware version supports this mode. Also confirm that the command and parameters are correct. The parameter choices are: 1) Disable "0" (default) 2) Allow version upgrade only "1" 3) Match firmware of replaced part "2" Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC006 Message Invalid Auto-Discovery action. Detailed Description The Auto-Discovery action selected is invalid. Recommended Response Action Verify that the selected Auto-Discovery action is supported.
LC008 Message Unsupported method parameter value. Detailed Description The parameter value is not supported. Recommended Response Action Confirm that the parameters provided are correct. For a list of parameters for this method refer to the Lifecycle Controller User Guide. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC0100 Message Lifecycle Controller has entered Recovery mode. Detailed Description A persistent error has occurred while carrying out a Lifecycle Controller operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC011 Message Certificate import operation failed. Detailed Description There was a general failure in the certificate import process. Recommended Response Action Try one of the following: 1) Rerun the command. 2) Reset iDRAC and run the command.
LC013 Message A configuration job cannot be created because there are no pending values to change. Detailed Description No changes are available between the previous configuration and the current configuration. At least one attribute should be changed to create a configuration job. Recommended Response Action Change the configuration of one or more attributes before creating a configuration job.
Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC016 Message Missing required parameter. Detailed Description A required method argument was missing. Recommended Response Action Include all the parameters required for the command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC018 Message Server certificate successfully modified. iDRAC will now restart and be unavailable during restart. Detailed Description The command was successful. Communication to iDRAC will be lost as iDRAC restarts to use the new server certificate. Recommended Response Action No response action is required.
LC020 Message PKCS12 decrypt of the certificate could not complete. Detailed Description The contents of the PKCS12 parameter was not valid because: 1) not a valid PKCS12 file 2) not a valid pfx file 3) did not contain a certificate that matched the private key in the file. Recommended Response Action Validate that the PKCS12 content was Base64 encoded. OpenSSL can be used to create or validate a PKCS12 encoding.
Recommended Response Action No response action is required. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC023 Message Cannot access network share.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC025 Message Insufficient space on network share. Detailed Description Insufficient space on network share. Recommended Response Action Make more space available on the network share and try the operation again.
Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC028 Message Unable to retrieve Hardware Inventory information. Detailed Description Hardware Inventory information is not retrievable due to an internal error.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC030 Message The file path is to a read-only file system. Detailed Description The file path specified for the operation is a read-only file system. Recommended Response Action Enable write access to the file path and try again.
Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC033 Message As-Shipped Hardware Inventory export was successful.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC035 Message As-Shipped Hardware Inventory Export method is not supported. Detailed Description This method is not supported in this version of Firmware. Recommended Response Action Update the iDRAC Firmware to a version that supports this method.
Detailed Description Lifecycle Controller is locked by another instance of Lifecycle ControllerLog Export operation. Wait for that operation to complete before attempting to run another command. Recommended Response Action Try one for the following: 1) Wait approximately 2 minutes and retry the operation. 2) Reset iDRAC and retry the operation. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC040 Message Memory resource allocation failure. Detailed Description Unable to allocate required memory to perform the operation. Recommended Response Action Power cycle system and retry the operation.
LC042 Message Configure Console name in FlexAddr mode Detailed Description Configure Console name while Virtual Address Management is in FlexAddr mode Recommended Response Action Configure the Virtual Address Management to Console mode, and then configure the name of a console. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Wait for the Lifecycle Controller system configuration wipe operation that is currently running to complete before requesting another operation. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC047 Message An instance of DownloadClientCerts is already running. Detailed Description The DownloadClientCerts operation is in progress. The operation may take a few minutes to compete before the operation can be attempted again. Recommended Response Action Wait a few minutes before retrying retry the operation.
LC049 Message Invalid value for VirtualAddressManagement. Detailed Description The value provided to set the attribute is invalid.. Recommended Response Action For more information on the valid values, see Lifecycle Controller-Remote Services documentation. Retry the operation with a valid value for the VirtualAddressManagement attribute. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Wait for the existing Server Profile Export job to run and complete or cancel it, before retrying the operation. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC054 Message Unable to write to the network share. Detailed Description The network share may be read-only or it may not have sufficient space for the export operation.. Recommended Response Action Verify the network share is not read-only and has sufficient space for exporting, then retry the operation.
LC056 Message AttributeName and AttributeValue count mismatch. Detailed Description The name value pairs in the input parameter arrays do not match in the input. Recommended Response Action Retry the operation with a valid (AttributeName, AttributeValue) pair. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC059 Message Cannot set read only attribute specified in AttributeName parameter. Detailed Description The attribute specified is read only and the value cannot be changed.
LC061 Message Lifecycle controller is ready to take provisioning requests Detailed Description Jobs, invoke methods, enumerates can now be performed on Lifecycle controller. Lifecycle controller is ready to take provisioning requests. Recommended Response Action No response action is required. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
22 LIC Event Messages LIC000 Message The License Manager action succeeded. Detailed Description This command was successful. Recommended Response Action No response action is required. Category Audit SubCategory LIC = Licensing Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
LIC002 Message License Manager is unable to allocate the required resources at startup. Detailed Description The error may occur when License Manager: 1) Is unable to allocate system resources. 2) Determines one or more files is incompatible with the current firmware version. This occurs when an older firmware version has been uploaded to a system that was previously running a newer firmware version.
LIC004 Message An internal system error has occurred. Detailed Description This error condition is reported when one of the following conditions occur: 1) Operating system detected a file error (for example, bad CRC, bad sector) when reading/writing a license manager file. The error could indicate bad or corrupt FLASH device. 2) License Manager detected an internal memory data corruption. 3) The command or command parameters passed to License Manager is invalid.
LIC006 Message The license has expired. Detailed Description The license end date has been reached. Recommended Response Action Obtain a replacement license and import it. Category Audit SubCategory LIC = Licensing Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Detailed Description All bound perpetual licenses contain the unique identifier of a specific device. The unique identifier binds a license to the device. For example, iDRACs unique identifier is the service tag. Recommended Response Action Obtain a new license file with the correct unique identifier for the device. To use this license, import to the device with the correct unique identifier.
Category Audit SubCategory LIC = Licensing Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC011 Message A non-evaluation license cannot be replaced with an evaluation license.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC013 Message These license features are not supported by this firmware version. Detailed Description The license includes features not supported in this firmware release. Recommended Response Action Update the firmware to the latest version.
LIC015 Message The License Manager database restore operation failed. Detailed Description This error occurs when the Lifecycle Controller restore operation is interrupted before it completes. This can occur due to a power outage or when a system is rebooted before the operation is completed. Recommended Response Action Repeat the Lifecycle Controller restore operation. If the problem persists, contact technical support.
Detailed Description This error can occur when the license file: 1) Signature is not valid. 2) Data is not in the correct format. 3) Missing needed data. 4) Contains unknown data. 5) Has not been unzipped. Recommended Response Action Download the license file, unzip and import the license. Category Audit SubCategory LIC = Licensing Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC020 Message Import failed: End User License Agreement (EULA) import upgrade warning. Detailed Description Importing an upgrade license without a base license is not allowed, as it may be a violation of the license EULA agreement.
LIC022 Message License Manager database locked due to ongoing backup and restore operation. Detailed Description License Manager database is locked while a backup and restore operation is in progress. License import/export/delete operations are not allowed but a user can view license information. Recommended Response Action Wait until the backup or restore operation completes and try again.
LIC202 Message A system error was detected during License Manager startup. Detailed Description This error can occur when: 1) Platform table has invalid value for default license feature set and permissible license upgrade path. In this case, the system sets the default licensed feature set to Basic Management and does not restrict the license upgrade path. 2) License Manager fails to load due to lack of system resources. Recommended Response Action Reset iDRAC.
Detailed Description This error occurs when the Lifecycle Controller restore operation is interrupted before it completes. This can occur due to a power outage or when the iDRAC is reset while the restore operation is in progress. Recommended Response Action Repeat the Lifecycle Controller restore operation. If the problem persists, contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
Recommended Response Action Remove the license if the import violates the EULA. Category Audit SubCategory LIC = Licensing Severity Severity 2 (Warning) Trap/EventID 8514 LCD Message No LCD message display defined. Initial Default. SNMP Alert;#EMAIL Alert;#LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE LIC207 License arg1 on device arg2 has expired.
Recommended Response Action No response action is required. Category Audit SubCategory LIC = Licensing Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE LIC209 License arg1 exported from device arg2 successfully.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE LIC211 Message The iDRAC feature set has changed. Detailed Description License import/delete/expiration resulted in a feature set change. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC502 Message Features not available. Detailed Description The attempted features are not available in the system. Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you.
LIC900 Message The command was successful. Detailed Description The operation was successful. Recommended Response Action No response action is required. Category Configuration SubCategory LIC = Licensing Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory LIC = Licensing Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC903 Missing parameters arg1. Message Arguments – Detailed Description arg1 = parameters One or more parameters were not specified for the invoked method.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC905 Message The LicenseName value cannot exceed 64 characters. Detailed Description The LicenseName value is greater than the allowed max length of 64. Recommended Response Action Correct the length of the LicenseName value and retry the operation.
Recommended Response Action Retry the operation. If this fails, reset iDRAC. Category Configuration SubCategory LIC = Licensing Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
23 LNK Event Messages LNK0001 Message No Share Name/Details present. Detailed Description No Share Name/Details present. Recommended Response Action Configure the network settings and retry. For more information, see configure USC network settings in Lifecycle Controller Users Guide. Category System Health SubCategory LNK = Link Status Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LNK2701 The arg1 LAN heartbeat is detected. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory LNK = Link Status Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
24 LOG Event Messages LOG001 Message Missing required InstanceID or JobID parameter. Detailed Description One or more required parameters needed for the method invoked in the operation are missing. Recommended Response Action To provide the correct value for the specified parameter, see Lifecycle ControllerRemote Services documentation. Category Configuration SubCategory LOG = Log event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LOG003 Message ConfigResults not available for log entry specified. Detailed Description The log entry with the specified InstanceID does not have any associated configuration results. Recommended Response Action Verify the ConfigResults availability for the InstanceID through enumeration of the LogEntry class and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation.
Category Configuration SubCategory LOG = Log event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LOG201 Message Recovered from LC Log corruption. Detailed Description LC Log corruption was detected during iDrac boot. LC Log was truncated at the point of corruption.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE TRUE 388 FALSE FALSE
25 MEM Event Messages MEM0000 Message Persistent correctable memory errors detected on a memory device at location(s) arg1. Arguments – Detailed Description arg1 = location The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Trap/EventID 2265 LCD Message Multi-bit memory error on . Reseat memory Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0002 Parity memory errors detected on a memory device at location arg1. Message Arguments – Detailed Description arg1 = location The memory is operational. This is an early indicator of a possible future uncorrectable error.
Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0004 Memory device at location arg1 is disabled. Message Arguments – Detailed Description arg1 = location The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Persistent correctable memory error limit reached for . Reseat memory. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0006 Memory device at location arg1 is present. Message Arguments – arg1 = location Detailed Description None Recommended Response Action No response action is required.
LCD Message Unsupported memory configuration. Check memory . Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0008 Memory device at location arg1 is spare memory. Message Arguments – arg1 = location Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0010 Memory device at location arg1 is over heating. Message Arguments – arg1 = location Detailed Description System performance is degraded. Recommended Response Action If unexpected, review system logs for power or thermal exceptions.
MEM0020 Memory device at location arg1 is enabled. Message Arguments – arg1 = location Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
MEM0022 Memory device at location arg1 is absent. Message Arguments – Detailed Description arg1 = location The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced. Recommended Response Action If unexpected, check presence, then re-install. Category System Health SubCategory MEM = Memory Severity Severity 2 (Warning) Trap/EventID 2266 LCD Message No LCD message display defined. Initial Default.
MEM0600 Memory device was added at location arg1. Message Arguments arg1 = location – Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
MEM0700 Message The persistent correctable memory error rate is at normal levels for a memory device at location arg1. Arguments – Detailed Description arg1 = location None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
MEM0702 Correctable memory error rate exceeded for arg1. Message Arguments – Detailed Description arg1 = location The memory may not be operational. This an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Correctable memory error rate exceeded for . Reseat memory.
MEM1001 Memory device at location arg1 failed to transition to a running state. Message Arguments – arg1 = location Detailed Description None Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory device failed to transition to a running state. Reseat memory Initial Default.
MEM1003 Memory device at location arg1 failed to transition to in test. Message Arguments – arg1 = location Detailed Description None Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health SubCategory MEM = Memory Severity Severity 2 (Warning) Trap/EventID 2266 LCD Message No LCD message display defined. Initial Default.
MEM1005 Memory device at location arg1 failed to power off. Message Arguments arg1 = location – Detailed Description None Recommended Response Action Re-attempt memory removal process Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default.
MEM1007 Memory device at location arg1 failed to transition to online. Message Arguments – arg1 = location Detailed Description None Recommended Response Action Re-attempt memory removal process Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default.
MEM1009 Memory device at location arg1 failed to transition to offline. Message Arguments – arg1 = location Detailed Description None Recommended Response Action Re-attempt memory removal process Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default.
MEM1011 Memory device at location arg1 is on-duty. Message Arguments – arg1 = location Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
MEM1013 Memory device at location arg1 is in a full state. Message Arguments – arg1 = location Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
MEM1015 Memory device at location arg1 is in a power active state. Message Arguments – arg1 = location Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
MEM1017 Memory device at location arg1 is installed correctly. Message Arguments – arg1 = location Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
Arguments arg1 = location – Detailed Description None Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory RAID lost on . Power cycle system Initial Default.
SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1204 Message Memory mirror is redundant. Detailed Description None Recommended Response Action No response action is required.
LCD Message Memory mirror lost on . Power cycle system Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1206 Memory mirror redundancy is degraded. Check memory device at location arg1. Message Arguments – Detailed Description arg1 = location The memory may not be seated correctly, misconfigured, or has failed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1208 Memory spare redundancy is lost. Check memory device at location arg1. Message Arguments arg1 = location – Detailed Description The assigned spare is no longer available. Recommended Response Action Review system logs for memory exceptions.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1210 Message Memory is redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
MEM1214 Message Memory redundancy is degraded. Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Recommended Response Action Review system logs for memory exceptions. Re-install memory at location Category System Health SubCategory MEM = Memory Severity Severity 2 (Warning) Trap/EventID 2266 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Review product documentation for proper memory riser installation and configuration Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory riser mismatch detected. Check memory riser Initial Default.
Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
26 NIC Event Messages NIC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration SubCategory NIC = NIC Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
NIC003 Message Missing required parameter Detailed Description An invalid number of arguments was passed to the method. Recommended Response Action Enter all the required command parameters. Check documentation and try again. Category Configuration SubCategory NIC = NIC Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory NIC = NIC Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC008 Message No pending data present to create a Configuration job Detailed Description No changes are available between the previous configuration and the current configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC010 Message Lifecycle Controller is not enabled, cannot create Configuration job. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC012 Message No pending data to delete. Detailed Description No changes to BIOS attribute data are available between the previous configuration and the current configuration. Recommended Response Action No response action is required.
NIC014 Invalid AttributeValue for AttributeName arg1 Message Arguments – arg1 = attribtue name Detailed Description AttributeValue may be invalid because of the following causes: \n1. Length of new AttributeValue is not within minLength and maxLength \n2. Value of new AttributeValue is not within LowerBound and UpperBound \n3.
NIC016 AttributeValue cannot be changed for disabled AttributeName arg1. Message Arguments – arg1 = attribute name Detailed Description A set attribute operation was attempted on a disabled attribute. Recommended Response Action No response action is required. Category Configuration SubCategory NIC = NIC Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory NIC = NIC Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC021 Message Cannot authenticate specified BIOS password. Detailed Description The incorrect old BIOS password was used during the operation to change the BIOS password to a new value.
NIC023 Message Cannot perform the operation due to an unknown error in iDRAC. Detailed Description The operation failed to run due to an unknown error in iDRAC. Recommended Response Action Retry the action. If this fails, reset iDRAC. Category Configuration SubCategory NIC = NIC Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Detailed Description The network link is down. Either the network cable is not connected or the network device is not working. Recommended Response Action Verify that the network port is enabled and if the port has Activity/Speed LEDs, that they are lit. Check the network cable, network cable connections, and the attached network switch. Category System Health SubCategory NIC = NIC Config Severity Severity 2 (Warning) Trap/EventID 2090 LCD Message No LCD message display defined.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC502 Message DHCP is required to be enabled on the NIC before DHCP can be \nenabled for DNS server or domain name objects. Detailed Description The value of the specified parameter cannot be changed.
NIC504 Message The IPv6 DNS Server IP address is not allowed to be configured if\n IPv6 DNS Server DHCP (cfgIPv6DNSServersFromDHCP6) is enabled Detailed Description The value of the specified parameter cannot be changed. Recommended Response Action Disable the cfgIPv6DNSServersFromDHCP6 object. Category System Health SubCategory NIC = NIC Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory NIC = NIC Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC507 Message Unable to determine current NIC state. Detailed Description For the requested operation, enable the NIC to get the NIC details.
NIC509 Message NIC is now ENABLED Detailed Description Success message. Recommended Response Action No response action is required. Category System Health SubCategory NIC = NIC Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC512 Message DHCP is already ENABLED Detailed Description Success message. Recommended Response Action No response action is required.
NIC514 Message DHCP is now ENABLED Detailed Description Success message. Recommended Response Action No response action is required. Category System Health SubCategory NIC = NIC Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
27 OSD Event Messages OSD1 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
OSD11 Message Driver Pack does not have drivers for the selected operating system. Detailed Description Lifecycle Controller does not have any drivers for the selected operating system. The operating system installation uses the native drivers present on the operating system media. Recommended Response Action No response action is required. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description iDRAC was unable to mount the drivers as a USB device for the OS installation to proceed. Recommended Response Action Reset iDRAC and rerun the command. Category Configuration SubCategory OSD = OS Deployment Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD16 Message Mount network share failed - incorrect IP address or share name. Detailed Description Unable to mount the network share using the parameters specified in the command because either the IP address or share name is incorrect.
OSD18 Message Unable to locate the ISO image on the network share point. Detailed Description Unable to find the ISO file specified in the network share. Make sure that the correct ISO file path was entered into the command and that all other user credentials are correct. Recommended Response Action Rerun the command with the correct ISO file path. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory OSD = OS Deployment Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD20 Message Unable to get size or label from Driver Pack for selected operating system.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD22 Message Unable to detach ISO image from the host. Detailed Description Unable to detach ISO image from the host because either the image is already detached, or iDRAC may not be operating normally. Recommended Response Action Reset iDRAC to automatically detach the ISO image.
OSD24 Message Unable to continue with DetachDrivers - UnPackAndAttach is in progress. Detailed Description Unable to continue with DetachDrivers - UnPackAndAttach is in progress. Recommended Response Action Wait until UnpackAndAttach finishes and then run DetachDrivers. This can take more than 5 minutes. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action See ConcreteJob status to make sure that the running process is complete, and then run BootToPXE. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD29 Message Driver Pack configuration file not found in Lifecycle Controller. The Driver Pack might be corrupt. Detailed Description Driver Pack config file not found in Lifecycle Controller. Driver Pack may be unusable.
OSD30 Message Invalid value for ExposeDuration - must be 60 - 65535 seconds Detailed Description The value specified for ExposeDuration is out of range. It must be between 60 and 65535 seconds Recommended Response Action Rerun the command with a ExposeDuration value between 60 and 65535 seconds. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action The call to DetachISOImage is unnecessary since the ISO image is not currently attached. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD33 Message Installed BIOS version does not support this method.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD35 Message Lifecycle Controller is not enabled. Detailed Description Lifecycle Controller is disabled on the system, so none of the remote operating system deployment commands will work. Make sure Lifecycle Controller is enabled before running any command.
OSD37 Message ISO image size too large. Detailed Description ISO Image size is bigger than the available size in VFlash. Recommended Response Action 1) Use a smaller size ISO Image. 2) Format the VFlash using the iDRAC GUI, RACADM, or iDRAC configuration utility and then retry this command. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD4 Message Cannot access Lifecycle Controller Driver Pack partition. Detailed Description Driver Pack partition in Lifecycle Controller is not accessible.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD41 Message ISO Image not found on VFlash. Detailed Description VFlash does not contain the ISO Image because either the image was deleted, or it was never copied. Recommended Response Action 1) Download the ISO Image to the VFlash again using the DownloadISOToVFlash winrm command.
OSD43 Message VFlash unavailable. Detailed Description VFlash is not present on the server. Recommended Response Action Insert a Dell-licensed VFlash and then retry this command. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD46 Message VFlash in use. Detailed Description Another process (iDRAC GUI /racadm/iDRAC configuration utility) is currently accessing VFlash.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD48 Message ISO Images of more than 4GB not supported. Detailed Description ISO Images of more than 4GB are not supported and cannot be copied to VFlash. Recommended Response Action Use an ISO that is smaller than 4GB.
Recommended Response Action Update the Driver Pack using USC or DUP and then run the command again. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD50 Message Lifecycle Controller is in field service mode.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD52 Message vFlash is disabled. Detailed Description vFlash is disabled. Recommended Response Action Enable the vFlash from the iDRAC GUI or RACADM, and then proceed. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Make sure that there are less than 16 partitions before creating another partition on vFlash. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD57 Message Remote File Share (RFS) is in Auto-Attach mode. Detailed Description Remote File Share (RFS) is currently configured to be in auto-attach mode. For Web services to attach an ISO, RFS should be changed to attach mode.
OSD59 Message Unable to disconnect from ISO using Remote File Share (RFS). Detailed Description Disconnecting ISO using Remote File Share (RFS) operation did not complete successfully. Recommended Response Action Reset iDRAC and retry the operation. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD61 Message IP Address format is invalid. Detailed Description The IP Address format is invalid and cannot be validated. The input IP address may not be a valid IPv4 or IPv6 address.
OSD8 Message Setting Boot to PXE through IPMI failed. Detailed Description The BIOS boot order set to PXE using a standard IPMI command has failed. Recommended Response Action 1) Check BIOS PXE settings. 2) Rerun the command. 3) Reset iDRAC and rerun the command. Category Configuration SubCategory OSD = OS Deployment Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
28 OSE Event Messages OSE0000 Message A critical stop occurred during OS load. Detailed Description The system halted due to an exception during operating system load or operating system initialization. Recommended Response Action Review operating system logs and system video for additional information Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID 2409 LCD Message No LCD message display defined. Initial Default.
OSE0002 Message An OS graceful stop occurred. Detailed Description (IPMI sensor type 20h - offset 02h). Recommended Response Action No response action is required. Category System Health SubCategory OSE = OS Event Severity Severity 3 (Informational) Trap/EventID 2411 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID 2409 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE OSE0005 Message Agent is not responding.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE OSE1001 Message Failed to boot from A. Detailed Description None Recommended Response Action review system boot configuration and boot media. Verify the media in a: is bootable. See system video for additional information.
OSE1003 Message Failed to boot from C. Detailed Description None Recommended Response Action Review system boot configuration and boot media. Verify the media in C: is bootable. See system video for additional information. Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID 2409 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Review system boot configuration, local PXE configuration, and PXE server configuration Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID 2409 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE OSE1006 Message Diagnostic boot completed.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE OSE1008 Message CD-ROM boot completed. Detailed Description The system OS has successfully booted from the CD-ROM. Recommended Response Action No response action is required. Category System Health SubCategory OSE = OS Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Detailed Description The system has successfully booted to ROM. Recommended Response Action No response action is required. Category System Health SubCategory OSE = OS Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE OSE1011 Message Failed to boot from ROM.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE OSE1013 Message Failed to boot. Detailed Description None Recommended Response Action Review system boot configuration and boot media. See system video for additional information Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
29 PCI Event Messages PCI1300 Message A front panel diagnostic interrupt was detected. Detailed Description The front panel diagnostic was pressed, and the system may be halted as a result. The interrupt was user induced. Recommended Response Action Reset the system to continue operation. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1304 Message An I/O channel check error was detected. Detailed Description None Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1308 A PCI parity error was detected on a component at bus arg1 device arg2 function arg3. Message Arguments – – – Detailed Description arg1 = bus arg2 = device arg3 = func System performance may be degraded, or system may fail to operate.
Trap/EventID 2417 LCD Message PCI system error on bus device function . Power cycle system. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1312 Message An EISA fail-safe time-out was detected. Detailed Description None Recommended Response Action No response action is required.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1316 A bus uncorrectable error was detected on a component at bus arg1 device arg2 function arg3. Message Arguments – – – Detailed Description arg1 = bus arg2 = device arg3 = func System performance may be degraded, or system may fail to operate.
Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message Fatal error on bus device function . Power cycle system. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1320 A bus fatal error was detected on a component at bus arg1 device arg2 function arg3.
Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device. Category System Health SubCategory PCI = PCI Device Severity Severity 2 (Warning) Trap/EventID 2418 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message An I/O channel check error detected. Power cycle system. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1346 A software error was detected on a component at slot arg1.
Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message PCI parity error on slot . Reseat PCI card Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1350 A PCI system error was detected on a component at slot arg1. Message Arguments – Detailed Description arg1 = number System performance may be degraded, or system may fail to operate.
Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1356 A bus uncorrectable error was detected on a component at slot arg1. Message Arguments – Detailed Description arg1 = number System performance may be degraded, or system may fail to operate.
LCD Message Fatal error on slot . Reseat PCI card Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1360 A bus fatal error was detected on a component at slot arg1. Message Arguments – Detailed Description arg1 = number System performance may be degraded, or system may fail to operate.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI2000 A fatal IO error detected on a component at bus arg1 device arg2 function arg3. Message Arguments arg1 = bus arg2 = device arg3 = func – – – Detailed Description System performance may be degraded, or system may fail to operate.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI2002 A fatal IO error detected on a component at slot arg1. Message Arguments – arg1 = number Detailed Description System performance may be degraded, or system may fail to operate.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3000 Message Device option ROM on embedded NIC failed to support Link Tuning or FlexAddress. Detailed Description Either the BIOS, BMC/iDRAC, or LOM firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, BMC/iDRAC, and LOM firmware. If problem persists please contact customer support.
PCI3002 Failed to program virtual MAC address on a component at bus arg1 device arg2 function arg3. Message Arguments – – – Detailed Description arg1 = bus arg2 = device arg3 = func Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, BMC/iDRAC, LOM, and mezzanine card firmware. If problem persists please contact customer support.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3004 Device option ROM on mezzanine card arg1 failed to support Link Tuning or FlexAddress. Message Arguments – Detailed Description arg1 = number Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3006 Message Failed to get Link Tuning or FlexAddress data from iDRAC. Detailed Description Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, and BMC/iDRAC firmware. If problem persists please contact customer support.
PCI3008 A non-fatal PCIe error detected on a component at bus arg1 device arg2 function arg3. Message Arguments – – – Detailed Description arg1 = bus arg2 = device arg3 = func System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next service window. Category System Health SubCategory PCI = PCI Device Severity Severity 2 (Warning) Trap/EventID 2418 LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3010 A non-fatal IO error detected on a component at bus arg1 device arg2 function arg3. Message Arguments – – – Detailed Description arg1 = bus arg2 = device arg3 = func System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next service window.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3012 Message The QuickPath Interconnect (QPI) width degraded. Detailed Description System performance may be degraded. The bus is not operating at maximum speed or width. Recommended Response Action Reset the system, if the problem persists reinstall processors.
PCI3014 A non-fatal PCIe error detected on a component at slot arg1. Message Arguments arg1 = number – Detailed Description System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next scheduled service time. Category System Health SubCategory PCI = PCI Device Severity Severity 2 (Warning) Trap/EventID 2418 LCD Message No LCD message display defined. Initial Default.
30 PDR Event Messages PRD96 Security was disabled on arg1. Message Arguments – arg1 = physical disk Detailed Description Security on a secure encrypted disk was disabled. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
31 PR Event Messages PR1 A replacement part was detected for device: arg1 Message Arguments – arg1 = device name Detailed Description The specified device has been replaced. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR11 Message Part Replacement license is not present, replacement action(s) will not be performed: arg1 Arguments – Detailed Description arg1 = device name A valid license for this feature is not present.
PR13 Message Firmware mismatch detected. Configuration changes not applied. Detailed Description The Part Replacement feature deteced a firmware difference and cannot apply the configuration changes. After the device firmware is updated, configuration changes can be applied. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments arg1 = device name – Detailed Description The configuration changes requested have not passed the device specific verification check and will not be applied. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Detailed Description Some of the configuration values stored for the previous device could not be applied to the current device. This may be due to firmware version or other differences in the part. Recommended Response Action Check the devices configuration and ensure that the new configuration is correct for the system. Category Configuration SubCategory PR = Part Exchange Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory PR = Part Exchange Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR2 Configuration difference detected for device: arg1 Message Arguments – Detailed Description arg1 = device name The specified device configuration is different from the previous device configuration.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR21 Message Job failed. Detailed Description The indicated job has failed. Recommended Response Action Check the Lifecycle Log for more details associated with this failure then retry the operation. Category Configuration SubCategory PR = Part Exchange Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Detailed Description The specified job is ready to start. It is waiting for scheduling from job control. This message is no longer in use in Lifecycle Controller 2.0 as the job control functionality handles this operation. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR26 Message Missing or corrupt job information. Detailed Description The configuration data associated with the inidicated job could not be located. Recommended Response Action Retry the operation.
PR28 Message Unable to locate device in current configuration. Detailed Description The device that the job was intended for is no longer detected. This could be due to the device being removed, disabled, or a failure. Recommended Response Action If the device was removed, reinsert the device and retry the operation. If the device was disabled, reenable the device and retry the operation.
Detailed Description The current component firmware version is higher than the replaced component firmware version. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR32 Message Failed verification of configuration changes. Detailed Description The configuration changes requested, for the indicated job, have not passed the device specific verifcation check and will not be applied.
PR34 arg1 failed after exceeding retry attempt limit. Message Arguments – Detailed Description arg1 = Job ID The job was attempted but failed unexpectedly. An AC Power loss, system crash, or other interruption during the jobprocessing can cause this failure.. Recommended Response Action Recreate and resubmit the job. Category Configuration SubCategory PR = Part Exchange Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
PR36 Firmware version change detected on arg1. Previous version: arg2, Current version: Message arg3 Arguments – – – arg1 = device name arg2 = previous version arg3 = current version Detailed Description The system has detected a different firmware version than previously recorded for the indicated device. This may be due to a firmware update, rollback, or part replacement. Recommended Response Action No response action is required.
PR5 Message The configuration values stored for the previous device could not be applied to device: arg1 Arguments arg1 = device name – Detailed Description Some or all configuration values stored for the previous device could not be applied to the current device. This may be due to firmware version or other differences in the part. Recommended Response Action Check the devices configuration and ensure that the new configuration is correct for the system.
PR7 New device detected: arg1 Message Arguments – arg1 = device name Detailed Description The specified device was added to the system. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
PR9 Message Firmware update operation initiated. Detailed Description The Part Replacement feature started the firmware update process based on Part Firmware Update attribute settings. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
32 PST Event Messages PST0128 Message No memory is detected. Detailed Description System BIOS was unable to detect memory in the system . This exception occurred early in system power on, thus the system may not display video (BIOS Post Exception 80). Recommended Response Action Inspect System Memory. Category System Health SubCategory PST = BIOS POST Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message No memory is detected. Inspect memory devices Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0130 Message Memory is configured, but not usable. Detailed Description During memory configuration system BIOS encountered device failures or speed configurations that resulted in unused memory. This exception occurred early in system power on, thus the system may not display video.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0132 Message CMOS failed. Detailed Description System BIOS detected a failure with CMOS memory during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception Code 84) Recommended Response Action Check system event log for CMOS battery exceptions. Remove and reapply input power.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0134 Message Interrupt controller failed. Detailed Description System BIOS detected a failure with the interrupt controller during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 86) Recommended Response Action Remove and reapply input power.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0136 Message Programmable interval timer error. Detailed Description System BIOS detected an failure with the programmable interval timer during POST. This exception occurred early in system power on, thus the system may not display video.(BIOS POST Exception code 88) Recommended Response Action Remove and reapply input power.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0138 Message SuperIO failed. Detailed Description System BIOS detected a failure with the SIO. This exception occurred early in system power on, thus the system may not display video. (BIOS POST code exception code 8A) Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0140 Message System management interrupt initialization failed. Detailed Description System BIOS failed to initialize the system management interrupt. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code 8C) Recommended Response Action Remove and reapply input power.
PST0142 Message MRC fatal error. Detailed Description BIOS Memory testing failed. Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration. This exception occurred early in system power on, thus the system may not display video. Recommended Response Action Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration.
PST0192 Message Shut-down test failed. Detailed Description System BIOS shutdown test failed during POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C0). Recommended Response Action Check system event log for CMOS battery exceptions. Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
PST0194 Message Remote access controller configuration failed. Detailed Description System BIOS could not configure the Remote Access controller This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code C2) Recommended Response Action Cycle input power and power on the system. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
PST0196 Message Incorrect memory configuration. Detailed Description System BIOS detected an invalid memory population. Reinstall the memory to match the supported population. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code C4) Recommended Response Action Re-install memory to match supported memory configuration.
PST0256 Message POST fatal error detected. Detailed Description System BIOS detected a functional or configuration issue during system POST. Check the system video screen for more information. The system event log may contain additional details. Recommended Response Action Check system video and review event log for additional information. Category System Health SubCategory PST = BIOS POST Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message POST fatal error detected.
33 PSU Event Messages PSU0000 Power supply arg1 is present. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID 2187 LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0002 A predictive failure detected on power supply arg1. Message Arguments – Detailed Description arg1 = number System performance and power redundancy may be degraded or lost. Recommended Response Action Remove and re-install the power supply at the next service window. If the issue persists, contact technical support.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0004 The power input for power supply arg1 is outside of range. Message Arguments – arg1 = number Detailed Description The operating requirements for the power supply may be found in product documentation or on the power supply itself. Recommended Response Action Verify the input source is attached to the power supply.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0006 Power supply arg1 is incorrectly configured. Message Arguments – Detailed Description arg1 = number Power supplies should be of the same input type and power rating. Recommended Response Action Install matched power supplies and review product documentation for proper configuration.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0017 Power supply arg1 is operating normally. Message Arguments arg1 = number – Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PSU0022 Power supply arg1 is correctly configured. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID 2187 LCD Message No LCD message display defined.
PSU0031 Cannot communicate with power supply arg1. Message Arguments – Detailed Description arg1 = number The power supply may operate, however power supply monitoring will be degraded. System performance may be degraded. Recommended Response Action Remove and re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
PSU0033 The temperature for power supply arg1 is outside of range. Message Arguments arg1 = number – Detailed Description System performance may be degraded. Recommended Response Action Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message PSU temperature outside of range.
PSU0035 An over voltage fault detected on power supply arg1. Message Arguments arg1 = number – Detailed Description None Recommended Response Action Check input power, replace or re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Over voltage fault on PSU .
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0037 Fan failure detected on power supply arg1. Message Arguments – arg1 = number Detailed Description None Recommended Response Action Check for fan blockage. If not replace the power supply.
PSU0076 A power supply wattage mismatch is detected; power supply arg1 is rated for arg2 watts. Message Arguments – – Detailed Description arg1 = number arg2 = value Power supplies should be of the same input type and power rating. Recommended Response Action Install matched power supplies and review product documentation for proper configuration.
PSU0078 Power supply arg1 revision mismatch detected. Message Arguments arg1 = number – Detailed Description This power supply revision is not supported for this system. Recommended Response Action Review product documentation, change power supply with correct revision. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message No LCD message display defined. Initial Default.
PSU0090 Power supply arg1 wattage mismatch corrected. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID 2187 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0801 Power Supply arg1: CRC error detected Message Arguments arg1 = PSU_Name – Detailed Description The Power Supply had a CRC error detected Recommended Response Action Aquire the power supply firmware image and update the power supply indicated in the message.
Detailed Description Insufficient power in chassis to power on blade. Recommended Response Action Utilize the Chassis Management Controller web interface to check available power and blade power requirements. If sufficient power is available, retry the operation. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0902 Power unit arg1 was power cycled. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0906 An interlock power down error detected on power unit arg1. Message Arguments – arg1 = number Detailed Description In order to meet service requirements the supply must be shut down. Recommended Response Action Remove input power at the power supply.
PSU0908 Power lost on power unit arg1. Message Arguments – Detailed Description arg1 = number The power supply is installed correctly but an input source is not connected or is not functional. Recommended Response Action Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) LCD Message No LCD message display defined.
Arguments arg1 = number – Detailed Description The system did not respond correctly to a power down request. Recommended Response Action Disconnect Input Power Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Check input power. Re-install the power supply. If problem persists contact support. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0913 Power unit arg1 is operating normally.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU1 Power supply in arg1 was disrupted. Message Arguments arg1 = Enclosure name – Detailed Description The power supply unit is not receiving input power. The power cable may not be connected properly or removed.
Severity Severity 1 (Critical) Trap/EventID 4233 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE PSU12 Power supply was removed from arg1. Message Arguments arg1 = enclosure name – Detailed Description An enclosure PSU was removed and is no longer functioning in optimal condition.
LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE PSU3 Message The DC power supply is switched off. Detailed Description The power supply unit is switched off. Either you have switched off the power supply unit or it is defective. Recommended Response Action Check to see whether the power switch is turned off or on.
PSU500 Message Unable to get the current server power status. Detailed Description Racadm tool cannot obtain the power status possible reason is that the IPMI call failed. Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PSU503 Server power status: arg1 Message Arguments – arg1 = Status Detailed Description Success message. Recommended Response Action No response action is required.
PSU6 Power supply in arg1 was inserted. Message Arguments arg1 = enclosure name – Detailed Description The enclosure detected that a power supply unit was inserted. Recommended Response Action No response action is required. Category Storage SubCategory PSU = Power Supply Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
34 PSUA Event Messages PSUA0016 Power supply arg1 is absent. Message Arguments – arg1 = number Detailed Description The supply has been removed or has failed. Recommended Response Action Install the power supply if needed. Category System Health SubCategory PSUA = PSU Absent Severity Severity 1 (Critical) Trap/EventID 2465 LCD Message PSU is absent. Check PSU Initial Default.
35 PWR Event Messages PWR0100 Message The power button was pressed. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR0103 Message The sleep button was released.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR0105 Message The reset button was released. Detailed Description The system will reset. Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR0108 The arg1 service was requested.
SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR1000 Message The system performance restored. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PWR1002 Message The system performance degraded because of thermal protection. Detailed Description To avoid shutdown, system performance has been degraded. Recommended Response Action Review system configuration and system logs for thermal or environmental failures and warnings.
PWR1004 Message The system performance degraded because power capacity has changed. Detailed Description To avoid shutdown, system performance has been degraded. Recommended Response Action if unintended, review system configuration changes and power policy. Category System Health SubCategory PWR = Power Usage Severity Severity 2 (Warning) Trap/EventID 2274 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Review system configuration, upgrade power supplies or reduce system power consumption. Category System Health SubCategory PWR = Power Usage Severity Severity 1 (Critical) Trap/EventID 2273 LCD Message System power exceeds capacity. System halted. Contact support Initial Default.
Severity Severity 1 (Critical) Trap/EventID 2273 LCD Message System power exceeds threshold. Performance degraded. Check PSU configuration Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PWR2000 Message The system powered up. Detailed Description None Recommended Response Action No response action is required.
PWR2002 Message The system warm reset. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2003 Message User requested a PXE boot.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2005 Message The OS run-time software initiated a hard reset. Detailed Description None Recommended Response Action No response action is required.
PWR2007 Message System restarted. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2200 Message The system is in the ON state.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2202 Message The system is sleeping with lost processor context. Detailed Description None Recommended Response Action No response action is required.
PWR2204 Message The system is in a non-volatile sleep state. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2208 Message The system is in a sleep state. Detailed Description None Recommended Response Action No response action is required.
PWR2210 Message The system was forced into a soft-off state. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PWR2402 Message Power management firmware not responsive. Detailed Description The iDRAC controller cannot communicate with the power management firmware. The system may operate in a performance degraded state. Recommended Response Action "1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash system BIOS.
36 RAC Event Messages RAC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – arg1 = parameter name Detailed Description One or more required parameters for the method are missing Recommended Response Action Refer to the profile document and provide the required parameters Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default.
RAC008 Message Invalid boolean Value Detailed Description The attribute boolean value is not valid for the given attribute Recommended Response Action Provide valid boolean value for the specified attribute Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0100 Message The Smart Card is removed. Further communication is not possible. Detailed Description Communication with the Smart Card has been lost.
RAC0102 Message The Smart Card Logon plug-in is not installed. Install the plug-in from the iDRAC Web GUI to log in using Smart Card. Detailed Description The software to communicate with the Smart Card is not loaded in this browser. Smart Card can be used for log in only if the appropriate Smart Card software is installed in the browser. Recommended Response Action Install the plug-in prompted by the iDRAC Web GUI to log in using Smart Card.
Detailed Description An invalid PIN was entered. Too many log in attempts with a Smart Card login can result in a user being locked out of the system. Recommended Response Action 1. Enter a valid Smart Card PIN and try again. 2. Use a different Smart Card. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0107 Message The inserted Smart Card cannot be recognized. Ensure that the correct Smart Card CSP drivers are installed.
LCD Message No LCD message display defined. Initial Default.
Detailed Description The IPv4 address does not conform to the addressing standard or the supported IPv4 address range. Recommended Response Action Enter the Destination IP Address value between [1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0118 Message Unsupported vFlash SD card detected. Detailed Description The SD card is not a valid vFlash SD card. The use of non-Dell media prevents the use of some extended capabilities and functions.
RAC0120 Message The selected partition size exceeds the available space. Detailed Description Requested partition size exceeds the available space. Recommended Response Action Enter a partition size smaller than the unused space on the vFlash SD card. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0126 Message The label value is invalid. Expected range: 1-6 alphanumeric characters. Detailed Description The label field is empty. A label is required to create an empty partition.
RAC0128 Message An error has occurred in vFlash. Detailed Description A non-specific error has been detected while accessing the vFlash. Recommended Response Action Try the operation again in a few minutes. If the problem persists, reset iDRAC before trying the operation again. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0130 Message An error has occurred while creating a partition. Detailed Description A seperate message will provide more detail about this error which was detected while creating the vFlash partition.
RAC0132 Message An error has occurred while formatting a partition. Detailed Description A seperate message will provide more detail about this error which was detected while formatting the vFlash partition. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0135 Message An error has occurred while detaching a partition.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0137 Message An error has occurred while changing the read-write state for the partition. Detailed Description A seperate message will provide more detail about this error which was detected while changing the read-write state of the vFlash partition. Recommended Response Action No response action is required.
Recommended Response Action Provide valid attribute Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0140 Message Firmware update has failed. Detailed Description The firmware update process returned an Update Failed status.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0142 Message File is not valid for iDRAC firmware update. Detailed Description The firmware update process identified an invalid firmware image. Recommended Response Action Upload a valid iDRAC firmware image.
RAC0147 Message Rollback firmware is not available. Detailed Description Firmware rollback image is missing or is corrupt. Recommended Response Action Upload a new firmware image. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
RAC0151 Message Unable to retrieve the removable flash media information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about removable flash media. Recommended Response Action Turn the system on to view this information. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0154 Message Non-redundant power mode: Secondary power supply has degraded.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0156 Message Unable to retrieve the voltage information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about system voltage. Recommended Response Action Turn the system on to view this information.
RAC0159 Message Certificate upload failed: No pending CSR or private key. Detailed Description Certificate upload failed because there is no pending Certificate Signing Request (CSR) or private key. Recommended Response Action Upload failed due to no pending Certificate Signing Request (CSR). Try creating a new CSR and then upload the certificate. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0169 Message Certificate upload failed: Certificate is not valid. Detailed Description Certificate upload failed because the certificate is not valid.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0171 Message Certificate upload failed: Certificate has expired. Detailed Description Certificate upload failed because the certificate has expired. Recommended Response Action Certificate has expired. Try creating a new Certificate Signing Request (CSR) and then upload the certificate.
Detailed Description Certificate upload failed. Unable to get local issuer certificate. The local issuer certificate is the certificate for the Certificate Authority (CA) that has signed the certificate for the Active Directory (AD) server, unless it is self signed. The iDRAC needs to verify that the CA is legitimate. Recommended Response Action Certificate has expired. Try creating a new CSR and then upload the certificate.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0206 Message Certificate upload failed: Not a certificate file. Detailed Description Certificate upload failed because this is not a certificate file. Recommended Response Action Upload a valid certificate.
RAC0208 Message Upload failed: May be due to invalid key data. Detailed Description Upload failed possibly due to invalid key data. Recommended Response Action Upload a certificate with a valid key. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0211 Message Firmware update has failed. Detailed Description Firmware update has failed. This may be due to a corrupt firmware image, poor network connection, or another issue.
RAC0213 Message Missing Username. Detailed Description Login page is missing a username. Recommended Response Action Enter a valid username. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0214 Message Missing Password.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0216 Message Login failed. Detailed Description Login failed because of an unknown reason. Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation.
RAC0218 Message The maximum number of user sessions is reached. Detailed Description A maximum of 4 iDRAC Web GUI sessions can be open at any time. Recommended Response Action Close one or more sessions before opening another session. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0221 Message The Destination E-mail Address is too long. The maximum length is 64 characters. Detailed Description The Destination E-mail Address can contain upto 64 characters.
RAC0223 Message Enter an alphanumeric value or a valid symbol for the following (see the online help for more information): Detailed Description The Subject line in the email contains invalid characters. Recommended Response Action Invalid character. Enter a valid value as mentioned in the online help. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0226 Message Send Failed: Request processing failed. Detailed Description Sending the test mail failed. This will prevent alert messages from being sent to this email address.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0228 Message SD Card is detected with an unrecognized format. Click Initialize to initialize the card. Detailed Description SD Card needs to be formatted to make it usable. The card must be initialized. Recommended Response Action Click Initialize to initialize the card and make it usable.
Detailed Description This message is displayed when a confirmation is required to initialize the vFlash SD Card. Recommended Response Action Press OK to initialize the SD Card. This will erase all data. If undesired press Cancel. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0236 Message Invalid image: Upload failed Detailed Description vFlash image upload failed because the image is not valid. Recommended Response Action Image may be corrupt. Try uploading a valid vFlash image.
RAC0238 Message vFlash is currently in-use by another process. Try again later. Detailed Description vFlash is unable to service the request at this time. Try again later. Recommended Response Action Try the operation after a few minutes. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0240 Message vFlash is disabled. Detailed Description vFlash needs to be enabled before attempting this operation. Recommended Response Action Enable vFlash before trying the operation.
RAC0242 Message The selected partition does not exist. Detailed Description The vFlash partition does not exist. This may be due to another user deleting that partition. Recommended Response Action Refresh the Web GUI page to see the available partitions. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0245 Message The partition is in-use by another process. Detailed Description The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0247 Message The partition is currently attached. Detailed Description This message is displayed when trying to format or download to an attached vFlash partition. Recommended Response Action Detach this partition and try again.
Detailed Description The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed. Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0251 Message One or more partitions are currently attached. Detailed Description The vFlash partitions are attached. Therefore, the current operation cannot proceed. Recommended Response Action Detach the partitions and try again.
Detailed Description This error message is displayed to indicate that the IPv4 address does not conform to the required format. Recommended Response Action Enter a valid IP Address. Expected range: [1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)]. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Enter a valid Subnet Mask. Expected ranges are: 255.XXX.0.0 [Class A], 255.255.XXX.0 Action [Class B], 255.255.255.XXX [Class C], and XXX.0.0.0 [others], where XXX must be valid (0,128,192,224,240,248,252,254). Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0259 Message Invalid IPv6 address. Detailed Description This error message is displayed to indicate that the IPv6 address does not conform to the required format.
RAC0260 Message Invalid IPv6 prefix length. Expected range: 0-128. Detailed Description The specified IPv6 address prefix length is invalid. Recommended Response Action Enter a valid IPv6 prefix length. Expected range: 0-128. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0263 Message The Alternate IPv6 DNS Server Address is invalid.
RAC0266 Message Invalid VLAN ID. Expected range: 1-4094. Detailed Description Specify a valid VLAN ID. Recommended Response Action Enter a valid VLan ID. Expected range: 1-4094. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0269 Message The NIC MTU is invalid. Expected range: 576-1500 or 0x240-0x5DC. Detailed Description Specify a valid NIC MTU. Recommended Response Action Enter a valid NIC MTU. Expected range: 576-1500 or 0x240-0x5DC.
RAC0270 Message IPv4 and IPv6 are disabled. Detailed Description This is a warning message that continuing this operation does not allow subsequent GUI interactions to this NIC. Recommended Response Action Enable IPv4 or IPv6 before continuing the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Disable NIC only if remote access is undesired. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0275 Message Click OK to disable the NIC. Click Cancel to keep the setting unchanged. Detailed Description If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled. Recommended Response Action Disable NIC only if remote access is undesired.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0278 Message Disabling IPv6 prevents access to iDRAC using an IPv6 address. Detailed Description This warning message appears when IPv6 is disabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC028 Message DHCP is Disabled so cannot Enable DNS Domain Name From DHCP or DNS From DHCP Detailed Description Cannot set enable those settings values when DHCP is disabled Recommended Response Action Enable DHCP to Enable DNS Domain Name From DHCP or DNS From DHCP Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Wa
Detailed Description This error message is displayed to indicate that the IP Subnet Mask does not conform to the required format. Recommended Response Action Enter a valid IP Subnet Mask. Expected range: 0.0.0.0 - 255.255.255.255. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0284 Message IP Blocking Fail Penalty Time is invalid. Expected range: 10-65535. Detailed Description This is the time span (in seconds) within which login attempts from an IP address with excessive failures are rejected.
RAC0286 Message New Password and Confirm New Password fields cannot be empty. Detailed Description When creating a user account, the New Password and Confirm New Password fields cannot be empty. Recommended Response Action Enter valid passwords for New Password and Confirm New Password. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
RAC0291 Message The user name cannot contain: /, \, @, ., or " (quotation mark). Detailed Description The user name value does not accept these characters. Recommended Response Action Do not enter /, \, @, ., or " (quotation mark) for user name. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0294 Message The Character Accumulate Interval value is invalid. Expected range: 1-255.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0297 Message Specify a Domain Controller Address must be configured. Detailed Description The Domain Controller Address be specified for Active Directory configuration.
RAC030 Message Required Attribute that this Attribute is dependent on has incorrect value Detailed Description The attribute value provided for the required attribute is invalid. Check documentation for correct values. Recommended Response Action Retry command with valid required attribute value Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0303 Message Virtual Console is disabled or you do not have the Access Virtual Console privilege.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC031 Message Invalid value specified for the User name Detailed Description User name specified is invalid Recommended Response Action Retry command with valid User name Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC036 Message Attribute dependency failed. Detailed Description The value of the specified attribute is dependent on the value of another attribute. The current value dependency is invalid. The other attribute value must be changed before the specified attribute value can be set.
Detailed Description The operation failed to run due to an unknown error in iDRAC. Recommended Response Action Retry the action. If this fails, reset iDRAC. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0400 Message iDRAC memory low. Detailed Description iDRAC is running low on memory. System performance may be degraded. Recommended Response Action No response action is required.
RAC042 Message Invalid number of input parameters. Detailed Description The number of input parameters provided is not valid to perform the operation. Recommended Response Action Verify that all required parameters are provided. Refer to the Lifecycle ControllerRemote Services documentation. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Verify the input parameters provided and retry the operation. Refer to the Lifecycle Controller-Remote Services documentation. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC047 Message Unsupported event action for the specified event filter. Detailed Description The event action selected is not supported for the event filter specified.
Recommended Response Action Reset iDRAC and retry the operation. Category Configuration SubCategory RAC = RAC Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0500 Message There are no batteries to be displayed. Detailed Description Batteries cannot be displayed.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0502 Message There are no virtual disks to be displayed. Detailed Description Virtual disks cannot be displayed. This error may occur if the host system is powered off or there are no virtual disks created. Recommended Response Action 1.
RAC0504 Message There are no enclosures to be displayed. Detailed Description Enclosures cannot be displayed. This error may occur if the host system is powered off, there is no enclosure connected to the controller, or there is a bad or disconnected adapter cable for the enclosure. Recommended Response Action 1. Check if the host system is ON. 2. Check if the Storage Enclosure is ON. 3. Verify that the adapter cables are properly connected and there are no bent pins.
Detailed Description This error occurs when the user tries to access a program or function that is beyond user granted privileges. Recommended Response Action Contact the system administrator to perform the operation or grant the required privileges. Category Storage SubCategory RAC = RAC Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0509 Message The server is temporarily unavailable. Try again after sometime Detailed Description The server is currently unable to handle the request due to temporary overloading or server maintenance.
RAC0511 Message There are no physical disks to be displayed. Detailed Description Physical disks cannot be displayed. This error may occur if the host system is powered off, physical disks are removed, or incorrect filters are applied. Recommended Response Action 1. Check if the host system is powered off or shutdown. 2. Check if the physical disks are inserted into the enclosure or attached to the backplane. 3. Check if correct filters are applied. 4. Check that the Storage Enclosure is on. 5.
Arguments – arg1 = email address Detailed Description An email page was successfully sent. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0703 Message Requested system hardreset. Detailed Description Requested system hardreset Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0706 Message Requested system NMI. Detailed Description Requested system NMI.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0708 Message Previous reboot was due to a firmware watchdog timeout. Detailed Description Previous reboot was due to a firmware watchdog timeout. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Recommended Response Action Ensure that the IO Module (IOM) and Mezzanine (Mezz) cards are appropriately matched. Check the M1000e Hardware Manual for correct component compatibility. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0713 Message Blade failed to power up due to fabric mismatch. Detailed Description Blade failed to power up due to fabric mismatched. Recommended Response Action Ensure that the hardware comtibility between the IO Module (IOM) and the Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct component compatibility.
RAC0715 Message Image file does not exist in the given remote share path. Detailed Description Image file does not exist in the given remote share path. Recommended Response Action Ensure that the image file is available on the share path provided. Retry the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0718 Message Remote File Share service is busy with the previous connection. Detailed Description Remote File Share service is busy with the previous connection.
RAC0720 Unable to mount remote share arg1. Message Arguments – arg1 = sharename Detailed Description Unable to mount remote share. Recommended Response Action Retry the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description Failed to program the Chassis assigned MAC address for the NIC.Integrated in the specified slot number. Recommended Response Action Reseat the blade and retry. Category Audit SubCategory RAC = RAC Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0903 Message The -d option cannot be used with any other options. Detailed Description The syntax of the specified command is invalid. In this case, the usage of the -d option is invalid. Recommended Response Action See the help text/documentation for valid syntax of the subcommand.
RAC0905 Message Failed to get the USC version details. Detailed Description Unable to obtain the USC version details. Recommended Response Action No response action is required. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0908 Message System ID LED blink off. Detailed Description The System ID LED was successfully set to off. Recommended Response Action No response action is required.
RAC0910 Message Invalid subcommand syntax: Specify group and object name. Detailed Description The specified command is missing group and object name syntax. Recommended Response Action Specify the correct subcommand group and object name syntax. See the help text or documentation for the valid syntax. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC913 Message Unable to login to RAC using the specified address Detailed Description The management system could not login to the iDRAC.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC915 Message 1000Mbps speed setting is Read Only and cannot be configured for the iDRAC NIC. Detailed Description Only possible configurations for the DRAC NIC are 10Mbps and 100 Mbps. For documentation with respect to this setting, refer to the racadm User Guide under cfgNetTuning group.
37 RDU Event Messages RDU0001 Message The fans are redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RDU = Redundancy Severity Severity 3 (Informational) Trap/EventID 2475 LCD Message No LCD message display defined. Initial Default.
RDU0003 Message Fan redundancy is degraded. Detailed Description One of more fans have failed or have been removed or a configuration change occurred which requires additional fans. Recommended Response Action Remove and re-install failed fans or install additional fans. Category System Health SubCategory RDU = Redundancy Severity Severity 2 (Warning) Trap/EventID 2474 LCD Message No LCD message display defined. Initial Default.
Detailed Description One of more fans have failed or have been removed or a configuration change occurred which requires additional fans. Recommended Response Action Remove and re-install failed fans or install additional fans. Category System Health SubCategory RDU = Redundancy Severity Severity 1 (Critical) Trap/EventID 2473 LCD Message No LCD message display defined. Initial Default.
SubCategory RDU = Redundancy Severity Severity 1 (Critical) Trap/EventID 2473 LCD Message Lost PSU redundancy. Check PSU cables Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE RDU0013 Message Power supply redundancy is degraded.
Trap/EventID 2475 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE RDU0015 Message The power supplies are not redundant. Insufficient resources to maintain normal operations. Detailed Description The system may power down or operate in a performance degraded state.
38 RED Event Messages RED000 Message Unrecognized error code encountered. Detailed Description An unknown error was returned. Recommended Response Action Check the uniform resource identifier (URI) target path and make sure the repository server is available. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
RED002 Message Package successfully downloaded. Detailed Description Package has been successfully downloaded. The Job Scheduler will schedule it at the time specified. Recommended Response Action Schedule the job if it is not already scheduled. Category Updates SubCategory RED = FW Download Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory RED = FW Download Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED005 Message The specified URI is invalid. Detailed Description The uniform resource identifier (URI) specified for the share location is invalid.
RED007 Message Package verification failed. Detailed Description Package verification failed. Recommended Response Action Verify that the package is a Dell-signed update package. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED010 Message The target specified is invalid. Detailed Description The target specified is invalid. Recommended Response Action Correct the target information and retry the operation.
RED011 Message USC version is not compatible. Detailed Description Current USC version does not support this component. Check InstanceID Recommended Response Action Use the latest version of USC available if possible. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED014 Message Job for this device is already present. Detailed Description A job for this update already exists in the queue and prevents the new job from being scheduled.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED016 Message Mount of remote share failed. Detailed Description The remote share location that has the ISO image did not mount correctly. Recommended Response Action 1. Verify that the path to the share is correct and that the parameters to the call are correct. 2. Verify that there are no network connectivity issues. 3.
Recommended Response Action 1. Update the device directly using the update methods since rollback is not supported for this device. 2. Verify that the target specified in the command is correct. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED021 Message The component InstanceID specified is not present on the system. Detailed Description The component InstanceID specified could not be located on the system. Recommended Response Action Ensure the component specified for updates is present in the system.
RED023 Message Lifecycle Controller in use. This job will start when Lifecycle Controller is available. Detailed Description Lifecycle Controller is unable to gain access to internal storage due to use by another application or operation. Recommended Response Action Wait for current Lifecycle Controller operation to complete.
39 RFL Event Messages RFL2000 Internal Dual SD Module arg1 is present. Message Arguments arg1 = name – Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFL = IDSDM Media Severity Severity 3 (Informational) Trap/EventID 2211 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE RFL2003 Internal Dual SD Module arg1 is online. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFL = IDSDM Media Severity Severity 3 (Informational) Trap/EventID 2211 LCD Message No LCD message display defined. Initial Default.
RFL2005 Internal Dual SD Module arg1 is operating normally. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFL = IDSDM Media Severity Severity 3 (Informational) Trap/EventID 2211 LCD Message No LCD message display defined. Initial Default.
RFL2007 Internal Dual SD Module arg1 is writable. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFL = IDSDM Media Severity Severity 3 (Informational) Trap/EventID 2211 LCD Message No LCD message display defined. Initial Default.
40 RFLA Event Messages RFLA2001 Internal Dual SD Module arg1 is absent. Message Arguments – arg1 = name Detailed Description The SD card module is not detected or not installed. Recommended Response Action If unintended, reinstall the SD module. Category System Health SubCategory RFLA = IDSDM Absent Severity Severity 1 (Critical) Trap/EventID 2481 LCD Message Internal Dual SD Module is absent. Check SD card. Initial Default.
41 RFM Event Messages RFM1018 Message Removable Flash Media is absent. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1021 Message Removable Flash Media is not IPMI-function ready.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1023 Message Removable Flash Media is not ready. Detailed Description The media is being prepared or is under maintenance. If the problem persists, reinstall the card. Recommended Response Action If unintended, reinstall the flash media.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1026 Message Failure detected on Removable Flash Media.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1028 Message Removable Flash Media was activated. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1031 Message Removable Flash Media has finished booting. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1033 Message Removable Flash Media is writable. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
42 RRDU Event Messages RRDU0001 Message Internal Dual SD Module is redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 3 (Informational) Trap/EventID 2491 LCD Message No LCD message display defined. Initial Default.
RRDU0003 Message Internal Dual SD Module redundancy is degraded. Detailed Description Either one of the SD card or both the SD cards are not functioning properly. Recommended Response Action Replace the failed SD card. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 2 (Warning) Trap/EventID 2490 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Review product documentation and SD card configuration. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 1 (Critical) LCD Message Internal Dual SD Module is not redundant. Insufficient resources. Check SD Cards Initial Default.
43 RSI Event Messages RSI0001 Message The Lifecycle Controller Remote Services is available. Detailed Description The Lifecycle Controller Remote Services instrumentation is available Recommended Response Action No response action is required. Category Configuration SubCategory RSI = Remote Service Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description The Remote Service database is being updated Recommended Response Action Retry request later Category Configuration SubCategory RSI = Remote Service Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
44 SEC Event Messages SEC0000 Message The chassis is open. Detailed Description The chassis is open. System performance may be degraded, and security may be compromised. Recommended Response Action Close the chassis. Check system logs. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message Intrusion detected. Check chassis cover Initial Default.
SEC0002 Message The I/O card area is open. Detailed Description The I/O card area is open. I/O cards may be added or removed. System performance may be degraded. Recommended Response Action Close the I/O card area. Check system logs. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
SubCategory SEC = Security Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0005 Message Unauthorized docking is detected. Detailed Description A removable component may have been tampered with, or installed incorrectly, or does not meet system requirements.
SEC0016 Message The chassis is closed. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) Trap/EventID 2387 LCD Message No LCD message display defined. Initial Default.
SubCategory SEC = Security Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0019 Message The processor area is closed. Detailed Description None Recommended Response Action No response action is required.
SEC0021 Message The docking is authorized. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0022 Message The fan area is closed.
Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message Intrusion detected. Check chassis cover Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE SEC0032 Message The chassis is closed while the power is on. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE SEC0034 Message The chassis is closed while the power is off. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) Trap/EventID 2387 LCD Message No LCD message display defined. Initial Default.
Detailed Description TXT initialization failure. System configuration may have changed. Recommended Response Action Check system hardware inventory and software configuration. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message BIOS detected an error configuring TXT. Check system configuration. Initial Default.
Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message BIOS detected a TXT error during POST. Check system configuration. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEC0044 Message SINIT Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) error at boot. Detailed Description TXT initialization failure.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEC0600 Message A secure mode violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Category System Health SubCategory SEC = Security Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0603 Message User password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
SEC0605 Message A setup password violation was corrected. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0608 Message A password violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
SEC0610 Message An Out-of-band password violation detected. Detailed Description This may apply to a remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies. Category System Health SubCategory SEC = Security Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
45 SEL Event Messages SEL0002 Message Logging is disabled. Detailed Description This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h) Recommended Response Action If unintended, re-enable logging. Category System Health SubCategory SEL = Sys Event Log Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
SEL0004 Message Log cleared. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID 2379 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL0008 Message Log is full. Detailed Description When the event log is full, additional events are not written to the log; or older events will be overwritten and lost.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEL0012 Message Could not create or initialize the system event log. Detailed Description if the system event log failed to initialize platform status and failure events are not captured. Some management software will not report platform exceptions. Recommended Response Action Reboot the management controller or iDRAC.
SEL1200 Message The system was reconfigured. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1202 Message OEM system boot.
SubCategory SEL = Sys Event Log Severity Severity 1 (Critical) Trap/EventID 2377 LCD Message Unknown system hardware failure. Contact support Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEL1205 Message The unknown system hardware failure was corrected. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1207 Message An entry was removed from auxiliary log. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Review platform event configuration. Category System Health SubCategory SEL = Sys Event Log Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1210 Message The time-stamp clock is synchronized.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1300 Message No bootable media found. Detailed Description System setup displays the system boot order. The local video screen may also show additional information. (IPMI sensor type code 1eh - offset 00h) Recommended Response Action Check system boot settings. Check mass storage controller configuration settings is applicable.
Detailed Description The disk in the drive is not formatted correctly or does not contain the necessary operating system files(IPMI sensor type code 1eh - offset 01h) Recommended Response Action Replace diskette with bootable disk. Category System Health SubCategory SEL = Sys Event Log Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1305 Message The PXE server found. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1308 Message A time-out occurred while waiting for user to select a boot source.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1400 Message The platform generated a page alert. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1406 Message The platform generated a SNMP trap. Detailed Description None Recommended Response Action No response action is required.
SEL1501 Message Chassis management controller (CMC) redundancy is lost. Detailed Description An action or failure has taken place that breaks CMC redundancy. This includes loss of network connection, hardware failures, firmware update, firmware mismatch between CMCs, CMC reset, and unplugging a CMC. Recommended Response Action Check CMC network cables and network connections. Check that CMC firmware versions match.
Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1504 Message The chassis management controller (CMC) is not redundant. Insufficient resources to maintain normal operations.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1507 Communications restored with Chassis Group Member arg1. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SEL1509 Member arg1 has joined the Chassis Group. Message Arguments arg1 = number – Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL9900 Message An unsupported event occurred.
Recommended Response Action See product documentation for additional information Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL9902 Message System software event.
46 STOR Event Messages SRD0505 Message Cannot delete virtual disks. Detailed Description Cannot delete virtual disks. Recommended Response Action Exit the RAID configuration wizard and retry, or reboot the system. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Detailed Description Provided parameter value is not valid Recommended Response Action Refer to the RAID profile to determine the valid parameters values Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR009 Message Physical disk FQDD did not identify a valid physical disk for the operation Detailed Description Physical disk did not identify valid physical disk for the operation.
Recommended Response Action Check if the server has power, RAID controller is available, and that a RAID controller is connected to the system. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0102 Message No batteries are displayed.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0104 Message No virtual disks are displayed. Detailed Description No virtual disk data to display. The system is powered off, physical disks are not present on the system, or virtual disks are not created.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0106 Message Fans are not connected to enclosures or data about fans is unavailable. Detailed Description No fan data to display. The system is powered off, no fan enclosures are present in the system, or the fans are not connected to the enclosures.
STOR0108 Message Temperature probes are not connected to enclosures or data about temperature is unavailable. Detailed Description No temperature data to display. The system is powered off, no enclosure temperature probes are present in the system, or the temperature probes are not connected to the enclosures. Recommended Response Action Check if the server has power, enclosure temperature probe is available, and temperature probe is connected to the enclosure.
Detailed Description Stripe size provided not valid for this controller. Recommended Response Action Provide a valid stripe size Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR012 Message Provided Physical disk not valid for this operation Detailed Description One or more of provided physical disks cannot be used.
STOR015 Message Maximum virtual disks allowed for this controller has been reached Detailed Description Hit maximum limit for virtual disks on the controller Recommended Response Action A new virtual disk cannot be created until one is deleted. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR018 Message No foreign drives detected Detailed Description This operation did not detect any foreign drives. This may be due to not having any foreign drives or the only foreign drives being secured.
STOR020 Message Controller Key is already present Detailed Description Controller key cannot be set because the key is already present. Recommended Response Action Controller already has a key. Key must be deleted to key the controller again. Category Configuration SubCategory STOR = Storage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR023 Message Configuration already committed, cannot set configuration Detailed Description A configuration has already been committed for this device.
STOR025 Message Configuration already committed, cannot delete pending configuration Detailed Description Cant delete pending configuration, job is already scheduled Recommended Response Action Must delete the configuration job to stop pending configuration changes. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR028 Message Virtual Disk not found Detailed Description Could not find the provided virtual disk Recommended Response Action Provide a valid virtual disk FQDD.
STOR030 Message Controller not found Detailed Description The provided controller could not be found Recommended Response Action Provide a valid controller FQDD. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
STOR032 Message Lifecycle Controller is currently in use. Detailed Description Lifecycle Controller is unable to gain access to internal storage due to use by another application or operation. Recommended Response Action Wait for current Lifecycle Controller operation to complete.
Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR038 Invalid parameter value for arg1 Message Arguments – arg1 = parameter Detailed Description The parameter value for the given parameter is invalid Recommended Response Action Provide a valid parameter value for specifed parameter Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD
Arguments – arg1 = attribute Detailed Description The attribute name provided is not valid for the current method Recommended Response Action Provide valid attribute Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR045 Message StartingLBA and Size parameters are required to create a Virtual Disk Detailed Description The input Physical Disks have fragmented disk space, so starting LBA and size parameters are required to create a Virtual Disk Recommended Response Action Provide startingLBA and size parameters.
Detailed Description AttributeValue cannot be changed for ReadOnly Attribute Name Recommended Response Action Cannot change this attribute. No action required Category Configuration SubCategory STOR = Storage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR050 Message Controller is in Dell Key Management mode Detailed Description Controller is in Dell Key Management mode Recommended Response Action Informational Message.
STOR0502 Message Failed to Launch RAID Configuration Wizard. Detailed Description USC- LCE failed while creating RAID configuration. Recommended Response Action Make sure the RAID controller is installed. Then, do the following: 1) Reboot the system. 2) Press the F10 key to re-enter Lifecycle Controller. 3) Retry RAID configuration. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory STOR = Storage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
STOR053 Message Controller key not present, controller needs key from Dell Key Management Server Detailed Description System could not obtain key from the Dell Key Management Server Recommended Response Action Refer to the DKM documentation for setting the Key management server. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR056 Message Physical disk is not security capable Detailed Description The physical disk does not support data encryption Recommended Response Action Informational Message. Refer to the controller users guide for more info.
STOR058 Message This operation is not supported on this device. Detailed Description The operation is not supported on the target device. Recommended Response Action Informational Message. Refer to the controller users guide for more info. Category Configuration SubCategory STOR = Storage Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action See the storage hardware documentation for information on checking the cables. Check for problems with any enclosures attached to the system. Verify that the controller has a supported version of the driver and firmware. Rebooting the system may resolve this problem. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID 4178 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Reboot the system or iDRAC. If the problem is not resolved, contact technical support. Category Storage SubCategory STOR = Storage Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR4 Message CEM Storage Management encountered internal error.
Recommended Response Action Identify and replace the failed components. To identify the failed component, select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a failed or degraded component. Click the controller that displays a Warning or Failed status. This action displays the controller Health subtab which displays the status of the individual controller components.
47 SUP Event Messages SUP001 Message Insufficient parameters provided. Detailed Description Insufficient Parameters provided for the WSMAN command. Recommended Response Action Make sure the parameters are correct and in the right number and format and retry the action. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SUP003 Message Invalid URI, target or reboot flag. Detailed Description One of the uniform resource input (URI) string, target or reboot flag parameters is missing or exceeds the prescribed length. Recommended Response Action Verify that the URI, target or reboot flag parameter values are correct and retry the action Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Wait until the update package is downloaded and retry the action. The download can take more than 5 minutes depending on network speed and size of the update package. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0100 Message Firmware update operation failed. Detailed Description The firmware update operation failed. Recommended Response Action No response action is required.
SUP0102 Message Invalid TFTP IP address specified. Detailed Description The TFTP IP Address specified is invalid. Recommended Response Action Specify a valid TFTP IP Address. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0105 Message Invalid firmware image Detailed Description The firmware image provided by the user is not valid. Recommended Response Action Provide a valid firmware image.
SUP0107 Message File path too long. Detailed Description The file path provided as a parameter is too long. Recommended Response Action Shorten the length of the string given as file path by either moving the file or renaming the folders along the path. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP011 Message Invalid Job ID specified. Detailed Description The specified Job ID was not found in the job queue. Recommended Response Action Verify the job ID and retry the action. Retrieve all open jobs by issuing the GetAllJobs command.
SUP0111 Message Timeout waiting for firmware update process to complete. Detailed Description Firmware Update time-out occurred. Recommended Response Action Re-try the firmware update process. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0114 Message The firmware update operation could not be completed successfully. Detailed Description The firmware update process failed. Recommended Response Action No response action is required.
SUP0116 Message The RAC configuration has initiated restoration to factory defaults. \nPlease wait up to a minute for this process to complete before accessing \nthe RAC again. Detailed Description Success message. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0119 Message Firmware rollback failed Detailed Description Success message. Recommended Response Action No response action is required.
SUP0121 Firmware update in progress [arg1 percent complete] Message Arguments – arg1 = Extent of completion Detailed Description Success message. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0124 Message Firmware update is not currently in progress Detailed Description Success message. Recommended Response Action No response action is required.
SUP0126 Message Firmware update in progress. Please wait... Detailed Description Success message. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0129 Message Resetting the RAC. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
SUP0130 Message TFTP firmware update has been initiated. This update process may take several minutes to complete. Detailed Description Success message. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory SUP = FW Update Job Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP015 Message Input parameters values should not be NULL. Detailed Description One of the parameters specified received a NULL value that prevented the action from completing.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP017 Message Invalid start time. Detailed Description The specified start time is invalid. Recommended Response Action Start Time should be in the form YYYYMMDDHHMMSS. Or it should be TIME_NOW to specify an immediate update or reboot. Verify the specified start time and retry the action.
Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation.
Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP022 Message Job store has reached the maximum storage limit. Detailed Description JobStore file has exceeded the size limit. Delete all unneeded JobIDs from the job store. \n \n Recom
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP024 Message InstanceID value provided for the update operation is invalid Detailed Description The InstanceID value provided for update operation is invalid.
Recommended Response Action If the catalog file is customized, then recreate the file using repository manager. Else, update the catlog file using Server Update Utility or from the service providers FTP server and retry. For more information, see Lifecycle Controller Users Guide. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0504 Message The catalog file in the update repository is not digitally signed. Detailed Description OEM produced update catalogs are digitally signed to prevent modifications.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0506 Message Decompression of the catalog file failed. Detailed Description The catalog file is corrupt or compressed in an unsupported format. Recommended Response Action Retry the operation with a different catalog.
Recommended Response Action Provide the correct login credentials and share name, and retry. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0509 Message Cannot mount the network share.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0511 Message Diagnostics content not found. Please use Platform Update to update diagnostics. Detailed Description The Diagnostics software is not installed or is corrupt.
SUP0513 Message update package path not found or path not accessible. Detailed Description An error occurred while copying the Update Package. Recommended Response Action Provide the correct file path and retry or exit the wizard and retry. If the problem persists, reboot the system and retry. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0516 Updating firmware for arg1 to version arg2. Message Arguments – – arg1 = component arg2 = Version Detailed Description Component firmware update is in progress.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0518 The firmware for arg1 to version arg2 updated successfully. Message Arguments – – arg1 = component arg2 = version Detailed Description The firmware for the component updated successfully. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0520 Firmware update operation for arg1 to version arg2 did not succeed. Message Arguments – – Detailed Description arg1 = component arg2 = version Firmware update operation by the component did not complete successfully. Recommended Response Action Retry the operation.
SUP0522 Message BIOS firmware image write protection is Enabled. Flash update is not allowed. Detailed Description Local BIOS update is disabled. Flash update is aborted. Recommended Response Action To flash the BIOS locally, enable Local BIOS update. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP1903 Message Firmware update verify image headers. Detailed Description Firmware update verify image headers. Recommended Response Action No response action is required.
SUP1905 Message Firmware update programming flash. Detailed Description Firmware update programming flash. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP1908 Message Firmware update failed checksum. Detailed Description Firmware update failed checksum. Recommended Response Action Reacquire the image from the original source and retry the operation.
SUP1910 Message Firmware update is not pending. Detailed Description Firmware update is not pending. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
48 SWC Event Messages SW0725 Message iDRAC7 communication failure. Detailed Description iDRAC7 is busy and does not respond to iDRAC7 configurator IPMI requests. Recommended Response Action Try AC power cycling the server or upgrade the iDRAC firmware. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
SWC0002 Message Error setting Component Configuration Policies. Detailed Description An unrecoverable error occurred in the operation while communicating with iDRAC. An iDRAC reset or power cycle is recommended. Additional information about the failure may be available in the Lifecycle Log. Recommended Response Action Retry the operation. If the problem persists 1) Turn off the system and disconnect the power cord. 2) Wait five seconds. 3) Reconnect the power cord and turn on the system.
Detailed Description An unrecoverable error occurred in the operation while communicating with iDRAC. An iDRAC reset or power cycle is recommended. Additional information about the failure may be available in the Lifecycle Log. Recommended Response Action Retry the operation. If the problem persists 1.) Turn off the system and disconnect the power cord. 2.) Wait five seconds. 3.) Reconnect the power cord and turn on the system.
Recommended Response Action Retry the operation. If the problem persists 1) Turn off the system and disconnect the power cord. 2) Wait five seconds. 3) Reconnect the power cord and turn on the system. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0009 Message Cannot load the iDRAC settings. Detailed Description An unrecoverable error occurred in the operation while communicating with iDRAC. An iDRAC reset or power cycle is recommended.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0011 Message The LCD Panel Security Settings were modified successfully. Detailed Description The LCD Panel Security Settings were modified successfully. Recommended Response Action No response action is required.
SWC0013 Message Cannot save the LCD Panel Security settings. Detailed Description An unrecoverable error occurred in the operation while communicating with iDRAC. An iDRAC reset or power cycle is recommended. Additional information about the failure may be available in the Lifecycle Log. Recommended Response Action Retry the operation. If the problem persists 1.) Turn off the system and disconnect the power cord. 2.) Wait five seconds. 3.) Reconnect the power cord and turn on the system.
Recommended Response Action Update Lifecycle Controller with the latest operating system driver packs from the service providers FTP server. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0018 Message Cannot apply the new boot mode settings for BIOS. Detailed Description As the new options cannot be applied, the current boot settings will be used.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0020 Message Cannot complete the Key Manager client configuration. Detailed Description iDRAC cannot set the Key Manager client configuration settings. Recommended Response Action Retry the operation. If the problem persists, 1) Turn off the system and disconnect the power cord. 2) Wait five seconds.
Detailed Description The Local Key Encryption passphrase provided does not authenticate. Recommended Response Action Use the correct passphrase and retry. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0025 Message The operation completed successfully, but the system cannot automatically shut down. Shut the system down manually. Detailed Description The operation completed successfully, but the system cannot automatically shut down. Shut the system down manually. Recommended Response Action Manually shut down the system.
SWC0027 Message The Server Profile backup operation that was initiated from Lifecycle Controller completed successfully. Detailed Description The Server Profile backup operation that was initiated from Lifecycle Controller completed successfully. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Additional information about the failure may be available in the Lifecycle Log. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0032 Message Backup file exported to USB device successfully. Detailed Description Exporting Backup file to the USB device was successful. Recommended Response Action No response action required.
Detailed Description Racadm is unable to read the available log records at this point. Retry the command. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0104 Message The -R option is not valid for the specified log. Detailed Description The specified log does not take in the -r option. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0107 Message More than one option is not allowed with this command. Detailed Description The command takes in only one option which is the Session ID.
SWC0109 Message No process information is currently available. Detailed Description There is no RAC diagnostic information available. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0112 Message Timeout while waiting for server to perform requested power action. Detailed Description A network time-out occurred while trying to perform the power action. Recommended Response Action No response action is required.
SWC0114 Message The -o option cannot be used with any other options. Detailed Description The syntax of the setniccfg command is invalid. Recommended Response Action Refer the help text for setniccfg subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0117 Message Invalid syntax. Both -f and -t must be specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Refer the help text for sslcertdownload subcommand.
SWC0119 Message Invalid certificate type specified with -t option. Detailed Description The syntax of the sslcertview command is invalid. Recommended Response Action Refer the help text for sslcertview subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0122 Message Invalid syntax. SSL key type (-t) must be specified. Detailed Description The syntax of the sslcertupload command is invalid. Recommended Response Action Refer the help text for sslcertupload subcommand.
SWC0124 Message The -u option requires -f to be specified. Detailed Description The syntax of the sslcsrgen command is invalid. Recommended Response Action Refer the help text for sslcsrgen subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0127 Message Unable to open file for writing. Detailed Description The file may be write protected and hence could not be edited. Recommended Response Action Check if the file is write protected.
SWC0129 Message Unable to send test email. Please make sure that your email alerts\nhave been configured correctly and connectivity to \nthe SMTP server exists. Detailed Description Racadm tool was not able to send a test email for the configuration. Recommended Response Action Check for the parameters mentioned in the message. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0132 Message Unable to send test trap. Please make sure that your trap\nhas been configured correctly and connectivity to \nthe destination endpoint exists.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0134 Message The RAC log was cleared successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0137 Message The coredump was deleted successfully Detailed Description Success message. Recommended Response Action No response action is required.
SWC0139 Total Records: arg1 Message Arguments – arg1 = Number of Records Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0142 Message Certificate successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required.
SWC0144 Message Certificate successfully uploaded to the RAC. The RAC will now reset\nto enable the new certificate and may be offline temporarily. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0147 Message ASR request completed successfully Detailed Description Success message. Recommended Response Action No response action is required.
SWC0149 Message Test trap sent successfully. Detailed Description The requested SNMP test trap alert was successfully sent. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0152 Message RAC configuration from file completed successfully Detailed Description Success message. Recommended Response Action No response action is required.
SWC0154 Message Generating CSR. Please wait... Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0157 Message User certificate successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required.
SWC0159 Message Kerberos Keytab successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0201 Message All keys successfully deleted Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0203 Message Key file successfully uploaded Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0206 Message View user certificate information Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0208 Message Disconnect Virtual Media connections Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0211 Message Perform vFlash operations Detailed Description Help Text. Recommended Response Action No response action is required.
SWC0213 Message Disable the Virtual Console from a local Console Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0216 Message The -c option requires -l to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command.
SWC0218 Message The -c option requires -p to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0221 Message The -l option requires -c to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command.
SWC0223 Message Invalid syntax. The -d option is not valid with -p. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0226 Message No valid directory service certificate exists Detailed Description The Remote/Firmware racadm did not find any AD/LDAP certificate at specified path. Recommended Response Action No response action is required.
SWC0228 Message Partition label must be an alphanumeric character string. Detailed Description Invalid values passed to the function. Recommended Response Action Enter a shorter Partition label. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0231 Message Partition of type \"image\" not supported on local racadm. Detailed Description The partition image type specified is not available on local racadm.
SWC0233 Message No indexes are available to configure additional groups. Detailed Description Indexed groups in the configuration file is more than the indexed groups in iDRAC. Recommended Response Action Verify if the number of indexed groups available in iDRAC match the indexed groups in the configuration file. If it does not match, either reset the unecessary indexes on iDRAC or remove the extra groups from the configuration file.
SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0236 Message Key successfully deleted. Detailed Description The specified public key was deleted from iDRAC. Recommended Response Action No response action is required.
SWC0238 Message Key is too long. Detailed Description The key specified by the public key is too long. Recommended Response Action Request for a valid public key from the system and re-try the command. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0241 Message Power Cap Enable not set. Unable to modify this property Detailed Description To modify this property, set the Power Cap Enable option.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0243 Message Certificate regenerated successfully and webserver restarted Detailed Description SSL Certificate is regenerated successfully and the Web server is restarted. Recommended Response Action No response action is required.
SWC0245 Message Failed to set object value because local configuration using RACADM is disabled. Detailed Description Local configuration using RACADM is disabled. This limits local configuration privileges such as resetting object values. Recommended Response Action Within group cfgRacTuning set the property cfgRacTuneLocalConfigDisable to 0. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Refer the list of subcommands. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0248 Message Invalid command syntax. Detailed Description The specified command has invalid syntax.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0250 Message Invalid syntax. The specified subcommand does not require any options. Detailed Description Extra parameters were passed. Recommended Response Action Enter the subcommand without any options.
SWC0252 Message No options were specified. The subcommand requires options to be used. Detailed Description Invalid number of arguments were passed to the command. Recommended Response Action Refer the help text for the command, and enter the required parameters. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0255 Message Unable to open file. Detailed Description Unable to open the specified file. Recommended Response Action No response action is required.
SWC0257 Message Invalid syntax. Too many options specified. Detailed Description Invalid number of arguments were passed to the command. Recommended Response Action Refer the help text for the command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0260 Message Invalid object specified. Detailed Description The value of specified parameter is invalid. Recommended Response Action Refer the list of objects in the corresponding group.
SWC0262 Message Unable to perform operation. Please make sure RAC controller and \nappropriate IPMI drivers are installed. Detailed Description The IPMI drivers or the RAC contorller may not be installed. Recommended Response Action Check if the required modules are installed. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0265 Message This option is not supported on this type of DRAC. Detailed Description The option requested is not available on the DRAC being used.
SWC0267 Message Unable to perform the requested operation. Make sure a non write protected SD card is inserted. Detailed Description Unable to edit the SD card, since it is write protected. Recommended Response Action Check if the SD card is write protected. If yes, disable the write protection. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0270 Message Unable to clear the SEL. \nPossible reason may be that Local Configuration using RACADM is disabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0272 Message Invalid syntax. The -g option is only valid with -o, -i, and -c. Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0275 Message Invalid syntax. The -c option is only valid with -f or -g. Detailed Description The syntax for the config command is invalid.
SWC0277 Message Invalid syntax. The -i option is only valid with -g and -o. Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0280 The indexed group specified requires -i arg1. Message Arguments – arg1 = index Detailed Description The group is indexed and an index needs to be specified.
SWC0282 Message The specified object is READ ONLY for this index and cannot be modified. Detailed Description The value being modified is READ only. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0285 Message Object value is invalid. Detailed Description The value given for the object is not valid. Recommended Response Action Enter a valid value for the corresponding object.
SWC0287 Message Invalid entry in configuration file. Detailed Description The value of a parameter in the config file is invalid. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
– – – arg2 = Object Name arg3 = Value arg4 = Line No. Detailed Description The specified objec value is invalid. Recommended Response Action Configure the specified object and assign a valid value. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0292 The specified object at index arg1 does not exist. Message Arguments – arg1 = index number Detailed Description The queried object does not exist at the specified index.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0294 Message Invalid group name specified. Detailed Description The group name specified is incorrect. Recommended Response Action Refer to the list of groups available and choose the correct one. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined.
Recommended Response Action Enter the command with the username and password. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0297 Message Unable to remove passwords because file could not be saved.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0299 Message The Destination Email Address is invalid. Detailed Description The Email Address provided is invalid. Recommended Response Action Specify a valid Email address.
Detailed Description The IP address provided is not valid. Recommended Response Action Specify a valid IP Address. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0302 Message The -s option is not valid with any other option.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0304 Message The -g option requires -u to also be specifed. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0307 Message The -d option requires -p or -g to also be specifed. Detailed Description The syntax of the fwupdate command is invalid.
SWC0309 Message The -p option is not supported with the interface being used. Detailed Description The platform does not support the specified functionality of fwupdate. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0312 Message Invalid syntax. The -u option is not valid with any other options. Detailed Description The syntax of the getconfig command is invalid. Recommended Response Action Refer the help text for getconfig subcommand.
SWC0314 Message Invalid syntax. The -o option requires -g to be specified also. Detailed Description The syntax of the getconfig command is invalid. Recommended Response Action Refer the help text for getconfig subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0317 Message The number of records to display must be greater than zero. Detailed Description The value for -c must be greater than zero. Recommended Response Action Enter a value greater than zero, for the option -c.
SWC0319 Message The -i option is not valid with any other options. Detailed Description The syntax for the getraclog command is invalid. Recommended Response Action Refer the help text for getraclog command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0322 Message Starting record specified exceeds number of records available. Detailed Description The starting record value has to be lesser than the number of records available.
SWC0324 Message There are no records available to display. Detailed Description There are no records to display. This might be a result of the log being cleared. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0701 Message Power capping is enabled. Detailed Description Power capping is enabled and sets user-defined power capping limits for the system. Recommended Response Action No response action is required.
SWC0717 Message iDRAC Local Configuration is disabled. iDRAC Settings are accessed in read-only mode. Detailed Description For security reasons, the local configuration is disabled. Enable local configuration from the iDRAC Web interface Recommended Response Action Enable iDRAC local configuration from iDRAC Web interface. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0724 Message Error occurred while Resetting to defaults due to a timeout. Detailed Description Resetting to defaults did not complete within the maximum process alloted time.
SWC1905 Message RAC Virtual Console configuration has been changed. Detailed Description RAC Virtual Console configuration has been changed. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC1911 User ID arg1 User Password has been changed.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC4004 A firmware or software incompatibility detected between iDRAC in slot arg1 and CMC. Message Arguments – Detailed Description arg1 = number FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Recommended Response Action Check firmware versions of iDRAC and CMC.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC4006 A firmware or software incompatibility detected between system BIOS in slot arg1 and CMC. Message Arguments – Detailed Description arg1 = number FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Recommended Response Action Check firmware versions of BIOS and CMC. Update to latest version.
SWC4008 Message A firmware or software incompatibility detected between CMC 1 and CMC 2. Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Recommended Response Action Check firmware versions. Update CMC 1 and CMC 2 firmware to match. Category System Health SubCategory SWC = Software Config Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory SWC = Software Config Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC5001 arg1 upgrade failed. Message Arguments – arg1 = name Detailed Description None Recommended Response Action Reboot the system and attempt the upgrade again.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE 914 FALSE FALSE
49 SYS Event Messages SYS001 Message The operation was successful. Detailed Description The operation requested successfully completed. Recommended Response Action No response action is required. Category Configuration SubCategory SYS = System Info Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – Detailed Description arg1 = parameter names One or more required parameters needed for the operation are missing. Recommended Response Action Refer to the Lifecycle Controller Remote Services documentation and retry the operation with the required parameters. Category Configuration SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS006 Unable to set read only attribute: arg1 Message Arguments – Detailed Description arg1 = attribute name The attribute being set is currently read-only and cannot be changed.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS008 Invalid boolean in value for attribute: arg1. Message Arguments – Detailed Description arg1 = attribute name The input value for the specified attribute is not a valid boolean value for the attribute.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS010 Invalid character in value for attribute: arg1 Message Arguments – Detailed Description arg1 = attribute name The input value for the specified attribute is not valid. Recommended Response Action Refer to Lifecycle Controller-Remote Services docuementation and provide valid attribute value for the specified attribute.
SYS012 Message User privileges are not sufficient to perform operation. Detailed Description The user credentials provided do not have appropriate privileges to perform the operation requested. Recommended Response Action Retry operation using user credentials that have appropriate privileges to perform the operation. Category Configuration SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Arguments – Detailed Description arg1 = attribute name The value provided for the specified attribute is invalid. Recommended Response Action For more information, refer to the Lifecycle Controller-Remote Services documentation and provide a valid value for the specified attribute. Category Configuration SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS017 Message Job did not complete successfully. Detailed Description The job did not complete successfully.
SYS019 Message Required dependency input not found. Detailed Description The input is missing a required dependency necessary for the operation. Recommended Response Action Provide the required dependency and retry. For more information, see Lifecycle Controller Remote Services documentation. Category Configuration SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Retry the operation. If the failure persists, 1) verify the value being set is correct, 2) reset the iDRAC. Category Configuration SubCategory SYS = System Info Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS022 Message Resource allocation failure.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS024 Message Attribute dependency failed. Detailed Description The provided attribute dependency value is invalid. Recommended Response Action For more information on the attribute dependency, see Lifecycle Controller Remote Services documentation.
Recommended Response Action None. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID 8579 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SYS1001 Message Host System is powering off Detailed Description Host system is powering off Recommended Response Action None.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SYS1003 Message Host System is performing a LPC reset Detailed Description Host System is performing a LPC reset Recommended Response Action None. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID 8579 LCD Message No LCD message display defined. Initial Default.
50 TMP Event Messages TMP0100 The system board arg1 temperature is less than the lower warning threshold. Message Arguments – arg1 = name Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0102 The system board arg1 temperature is greater than the upper warning threshold. Message Arguments – arg1 = name Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures.
TMP0104 The system board arg1 temperature is outside of range. Message Arguments – arg1 = name Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message System board temperature is outside of range Check Fans Initial Default.
TMP0106 The memory module arg1 temperature is less than the lower warning threshold. Message Arguments – arg1 = number Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
TMP0108 The memory module arg1 temperature is greater than the upper warning threshold. Message Arguments – Detailed Description arg1 = number Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
TMP0110 The memory module arg1 temperature is outside of range. Message Arguments – arg1 = number Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message Memory module temperature is outside of range. Check Fans Initial Default.
TMP0112 The arg1 temperature is less than the lower warning threshold. Message Arguments arg1 = name – Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
TMP0114 The arg1 temperature is greater than the upper warning threshold. Message Arguments – arg1 = name Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
TMP0116 The arg1 temperature is outside of range. Message Arguments – arg1 = name Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message The temperature is outside of range. Check Fans Initial Default.
TMP0118 Message The system inlet temperature is less than the lower warning threshold. Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0121 Message The system inlet temperature is greater than the upper critical threshold. Detailed Description Ambient air temperature is too warm.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0123 Message The system inlet temperature is within range. Detailed Description None Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 3 (Informational) Trap/EventID 2163 LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0128 Message Disk drive bay temperature is outside of range. Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures.
TMP0130 Message The control panel temperature is less than the lower warning threshold. Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0133 Message The control panel temperature is greater than the upper critical threshold.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0135 Message The control panel temperature is within range. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory TMP = Temperature Severity Severity 3 (Informational) Trap/EventID 2163 LCD Message No LCD message display defined. Initial Default.
TMP0201 CPU arg1 temperature is less than the lower critical threshold. Message Arguments arg1 = number – Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message CPU temperature is outside of range. Check fans Initial Default.
TMP0203 CPU arg1 temperature is greater than the upper critical threshold. Message Arguments arg1 = number – Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment, fans, and heatsinks. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message CPU temperature is outside of range. Check fans Initial Default.
TMP0205 CPU arg1 temperature is within range. Message Arguments – arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory TMP = Temperature Severity Severity 3 (Informational) Trap/EventID 2163 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE TMP2 arg1 has crossed the minimum warning threshold. Message Arguments – Detailed Description arg1 = tempsensor name The enclosure is too cold. Recommended Response Action Check whether the thermostat setting is too low and whether the room temperature is too cool.
LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE TMP4 arg1 has crossed the minimum failure threshold. Message Arguments – Detailed Description arg1 = tempsensor name The enclosure is too cold. Recommended Response Action Check whether the thermostat setting is too low and whether the room temperature is too cool.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE TMP6 The temperature probe minimum warning value was changed on arg1. Message Arguments – Detailed Description arg1 = Enclosure name You have changed the value for the minimum temperature probe warning threshold. This alert is provided for informational purposes. Recommended Response Action No response action is required.
51 TST Event Messages TST100 Message The operation was successful. Detailed Description The operation completed successfully. Recommended Response Action No response action is required. Category Configuration SubCategory TST = Test Alert Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description The destination address of the email is not configured. Recommended Response Action Configure the email alert destination address and retry the operation. Category Configuration SubCategory TST = Test Alert Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE TST105 Invalid parameter value for arg1. Message Arguments – Detailed Description arg1 = parameter name The value provided for the specified parameter is invalid.
52 UEFI Event Messages UEFI0000 Message CPU Exception Type 0x00: Divide by Zero (Software). Detailed Description A CPU type 0x00, divide by zero exception, (type 0x00) occurred in the pre-boot UEFI environment. The software attempted to do a mathematical divide by zero, an illegal operation. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
UEFI0002 Message CPU Exception Type 0x04: Overflow (Software). Detailed Description A CPU overflow exception (type 0x04) occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software. Category System Health SubCategory UEFI = UEFI Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software. Category System Health SubCategory UEFI = UEFI Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE UEFI0007 Message CPU Exception Type 0x09: Coprocessor Segment Overrun (Software). Detailed Description A CPU coprocessor segment overrun exception (type 0x09) occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception.
UEFI0009 Message CPU Exception Type 0x0B: Segment Not Present (Software). Detailed Description A CPU segment not present exception (type 0x0B) occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software. Category System Health SubCategory UEFI = UEFI Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software. Category System Health SubCategory UEFI = UEFI Event Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE UEFI0014 Message CPU Exception Type 0x11: Alignment Check (Software). Detailed Description A CPU alignment check exception (type 0x11) occurred in the pre-boot UEFI environment.
53 USR Event Messages USR0002 arg1 login from arg2. Message Arguments arg1 = username arg2 = ip_address – – Detailed Description Details the Username that logged in and the IP Address they are coming from. Recommended Response Action No response action is required. Category Audit SubCategory USR = User Tracking Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE USR0007 arg1 closing session from arg2. Message Arguments arg1 = username arg2 = ip_address – – Detailed Description UserID closing session from IP Address. Recommended Response Action No response action is required.
Detailed Description The user session which is currently in use is invalid. Recommended Response Action No response action is required. Category Audit SubCategory USR = User Tracking Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR0015 Message The specified user does not exist.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR0017 Message No active sessions currently exist for the specified user. Detailed Description There are no active sessions on the iDRAC for the specified user. Recommended Response Action No response action is required.
Category Audit SubCategory USR = User Tracking Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR0020 Message Invalid Session ID. Detailed Description The specified session id does not exist and is invalid. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR0022 Message The specified user already exists. Duplicate user names are not allowed. Detailed Description The username specified already exists and cannot be assigned. Recommended Response Action Choose a unique username.
Recommended Response Action No response action is required. Category Configuration SubCategory USR = User Tracking Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR103 Missing parameters arg1. Message Arguments arg1 = parameter names – Detailed Description One or more required parameters needed for the operation are missing. Recommended Response Action Refer to the Lifecycle Controller Remote Services documentation and provide the required parameters.
USR105 Message The account is not configured. Detailed Description The user account used as credentials to access iDRAC is not enabled or configured to perform the operation. Recommended Response Action Retry the operation after creating the user account. Category Configuration SubCategory USR = User Tracking Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
USR107 arg1 operation by arg2 on arg3 of arg4 Message Arguments – – – – arg1 = SET/INVOKE arg2 = username arg3 = methodname/instance arg4 = classname Detailed Description An operation has been performed on the iDRAC by the specified user. It is either a set on an instance of the class or an invoke on the method of the class Recommended Response Action No response action is required.
54 VDR Event Messages VDR1 arg1 failed. Message Arguments – arg1 = VD Name Detailed Description A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency. Recommended Response Action Replace the failed component. You can identify which component has failed by locating the component that has a red "X" for its status.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR11 arg1 has started initializing. Message Arguments arg1 = virtual disk – Detailed Description This message is generated after initialization of a virtual disk starts. Recommended Response Action No response action is required.
VDR13 arg1 rebuild has started. Message Arguments – arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – Detailed Description arg1 = virtual disk The initialization operation could not be completed. This may be due to a user action or a physical disk failure. Recommended Response Action If a physical disk failed, then replace the physical disk. Restart the virtual disk initialization. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – Detailed Description arg1 = VD Name A physical disk included in the virtual disk failed. Recommended Response Action Replace the failed physical disk. Identify the failed physical disk by locating the disk that has a red "X" for its status. Rebuild the physical disk. When finished, restart the virtual disk format operation. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
Detailed Description The reconfiguration operation was not completed. This may be due to a user action or a physical disk failure. Recommended Response Action Recreate the virtual disk and restore data from a backup copy. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) Trap/EventID 4353 LCD Message No LCD message display defined. Initial Default.
Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR21 Consistency check for arg1 has completed. Message Arguments – arg1 = virtual disk Detailed Description This message is generated after a consistency check completes on a virtual disk.
Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR23 Initialization of arg1 has completed. Message Arguments – arg1 = virtual disk Detailed Description This message is generated after initialization completes on a virtual disk. Recommended Response Action No response action is required.
VDR25 arg1 rebuild is completed. Message Arguments – arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments – arg1 = VD Name Detailed Description The check consistency on a virtual disk has resumed processing after a pause. Recommended Response Action This alert is provided for informational purposes. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Recommended Response Action This alert is provided for informational purposes. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR3 Redundancy normal on arg1.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR31 Controller cache is preserved for missing or offline arg1. Message Arguments arg1 = VD Name – Detailed Description The controller is getting disconnected from its virtual disk, while Input Output (IO) is inprogress.
Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE VDR33 Background initialization was cancelled for arg1. Message Arguments – Detailed Description arg1 = virtual disk Background initialization of a virtual disk was cancelled. This may be due to user action.
Trap/EventID 4353 LCD Message No LCD message display defined. Initial Default. SNMP Alert Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE VDR35 Background initialization has completed for arg1. Message Arguments – arg1 = virtual disk Detailed Description Background initialization of a virtual disk completed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR37 Dead disk segments are restored on arg1. Message Arguments arg1 = VD Name – Detailed Description Disk space that was formerly "dead" or inaccessible to a redundant virtual disk has been restored. This alert is provided for informational purposes. Recommended Response Action No response action is required.
VDR39 The check consistency has made corrections and completed for arg1. Message Arguments arg1 = VD Name – Detailed Description The virtual disk check consistency has identified errors and made corrections. For example, the check consistency may have encountered a bad disk block and remapped the disk block to restore data consistency. This alert is provided for informational purposes. Recommended Response Action This Alert is for informational purposes only and no additional action is required.
VDR40 The reconfiguration of arg1 has resumed. Message Arguments – arg1 = virtual disk Detailed Description This message is generated after the reconfiguration of a virtual disk resumes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR43 Dedicated hotspare unassigned physical disk arg1.
LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR45 arg1 blink has been initiated. Message Arguments – arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
VDR47 A disk media error was corrected on arg1. Message Arguments – Detailed Description arg1 = virtual disk A disk media error was detected while the controller was completing a background task. A bad disk block was identified. The disk block was remapped. Recommended Response Action Check the Lifecycle log for information related to members of this virtual disk. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
VDR49 arg1 is permanently degraded. Message Arguments arg1 = VD Name – Detailed Description A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the failure of more than one physical disk. In this case, both the source physical disk and the target disk with redundant data have failed. A rebuild is not possible because there is no longer redundancy. Recommended Response Action Replace the failed disks and restore from backup.
VDR50 Background Initialization (BGI) completed with uncorrectable errors on arg1. Message Arguments arg1 = virtual disk – Detailed Description The background initialization task encountered errors that cannot be corrected. The virtual disk contains physical disks that have unusable disk space or disk errors that cannot be corrected. Recommended Response Action Review other messages to identify whether the physical disk that has errors.
VDR52 The consistency check found inconsistent parity data on arg1. Message Arguments arg1 = virtual disk – Detailed Description The data on physical disk members of the virtual disk does not match. Redundancy may be lost. Recommended Response Action Rerun the consistency check task. If you receive this message again, verify the health of the physical disks included in the virtual disk. See the storage hardware documentation for more information.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE VDR54 arg1 initialization is terminated. Message Arguments – arg1 = VD Name Detailed Description You have cancelled the virtual disk initialization. Recommended Response Action Restart the initialization. Category Storage SubCategory VDR = Virtual Disk Severity Severity 2 (Warning) LCD Message No LCD message display defined.
VDR56 Redundancy of arg1 was lost. Message Arguments arg1 = virtual disk – Detailed Description This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt. Recommended Response Action Replace the missing or failed physical disk.
VDR58 Bad block medium error is detected at block arg1 on arg2. Message Arguments arg1 = args arg2 = VD Name – – Detailed Description Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member physical disks. Recommended Response Action Recovering a physical disk bad block depends on the RAID level and state of the virtual disk. If a virtual disk is redundant, the controller can recover a bad block on a physical disk.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE VDR6 arg1 configuration has changed. Message Arguments – arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR8 arg1 has become degraded. Message Arguments arg1 = virtual disk – Detailed Description This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE VDR91 Consistency check for arg1 has detected multiple uncorrectable medium errors. Message Arguments arg1 = virtual disk – Detailed Description This message occurs if there are medium errors in the physical drives. Recommended Response Action Replace the failed drives.
VDR93 arg1 bad block medium error is cleared. Message Arguments – arg1 = VD Name Detailed Description This alert message occurs if there are medium errors in the physical drives. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default.
VDR95 Unable to log block arg1.Bad block table on arg2 is full. Message Arguments – – Detailed Description arg1 = arg arg2 = VD Name This alert message occurs if the virtual disk has bad blocks. Recommended Response Action Replace the disk in the Virtual disk, generating this alert and restore from backup. You may have lost data. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default.
VDR97 Patrol Read corrected a media error on arg1. Message Arguments – Detailed Description arg1 = VD Name The Patrol Read task has encountered an error such as a bad disk block and remapped data to correct the error. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
55 VF Event Messages VFL0719 Message One or more partitions are in use; the SD card could not be initialized. Detailed Description The SD card is in use by another process. Initialization requires exclusive access to the SD card to complete the initialization. Recommended Response Action The SD card is in use by another process. Retry after a few minutes. Category Configuration SubCategory VF = vFlash Media Severity Severity 1 (Critical) LCD Message No LCD message display defined.
56 VFL Event Messages VFL1001 Removable Flash Media arg1 is present. Message Arguments arg1 = name – Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID 2507 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VFL1003 Removable Flash Media arg1 is not IPMI-function ready. Message Arguments – Detailed Description arg1 = name The removable flash media is installed but improperly configured or failed to initialize. Recommended Response Action If unintended, reinstall the flash media and module.
VFL1005 Removable Flash Media arg1 is not ready. Message Arguments – Detailed Description arg1 = name The media is being prepared or is under maintenance. If the problem persists, reinstall the card. Recommended Response Action Please wait for the media to be ready. Category System Health SubCategory VFL = vFlash Event Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default.
VFL1007 Removable Flash Media arg1 is online. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Arguments arg1 = name – Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID 2507 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VFL1010 Removable Flash Media arg1 was activated.
Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID 2507 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VFL1012 Removable Flash Media arg1 is booting.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VFL1014 Removable Flash Media arg1 is write protected. Message Arguments – Detailed Description arg1 = name The card is write-protected by the physical latch on the SD card. IDSDM cannot use a write-protected card.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VFL1016 Media not present for Removable Flash Media arg1. Message Arguments – arg1 = name Detailed Description The SD card is not detected or not installed. Recommended Response Action If unintended, reinstall the flash media.
57 VFLA Event Messages VFLA1000 Removable Flash Media arg1 is absent. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFLA = vFlash Absent Severity Severity 3 (Informational) Trap/EventID 2515 LCD Message No LCD message display defined. Initial Default.
58 VLT Event Messages VLT0100 Processor module arg1 voltage is less than the lower warning threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins.
LCD Message Processor module voltage is outside of range. Contact support Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VLT0102 Processor module arg1 voltage is greater than the upper warning threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VLT0104 Processor module arg1 voltage is outside of range. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VLT0200 The system board arg1 voltage is less than the lower warning threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Trap/EventID 2169 LCD Message The system board voltage is outside of range. Contact support Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0202 The system board arg1 voltage is greater than the upper warning threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message The system board voltage is outside of range. Contact support Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0204 The system board arg1 voltage is outside of range.
Category System Health SubCategory VLT = Voltage Severity Severity 3 (Informational) Trap/EventID 2171 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VLT0206 The memory module arg1 arg2 voltage is less than the lower warning threshold.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
VLT0209 The memory module arg1 arg2 voltage is greater than the upper critical threshold. Message Arguments – – arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0211 The memory module arg1 arg2 voltage is within range. Message Arguments – – arg1 = number arg2 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VLT = Voltage Severity Severity 3 (Informational) Trap/EventID 2171 LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0213 The disk drive bay arg1 voltage is less than the lower critical threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0215 The disk drive bay arg1 voltage is greater than the upper critical threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0217 The disk drive bay arg1 voltage is within range. Message Arguments – arg1 = name Detailed Description None Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0219 The arg1 voltage is less than the lower critical threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
SubCategory VLT = Voltage Severity Severity 2 (Warning) Trap/EventID 2170 LCD Message No LCD message display defined. Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0221 The arg1 voltage is greater than the upper critical threshold. Message Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message The voltage is outside of range. Contact support Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0223 The arg1 voltage is within range.
Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory VLT = Voltage Severity Severity 2 (Warning) Trap/EventID 2170 LCD Message No LCD message display defined. Initial Default.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Arguments – arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Arguments – – arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
VLT0232 The mezzanine card arg1 arg2 voltage is greater than the upper warning threshold. Message Arguments – – arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0234 The mezzanine card arg1 arg2 voltage is outside of range. Message Arguments – – arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VLT0300 CPU arg1 arg2 voltage is less than the lower warning threshold. Message Arguments arg1 = number arg2 = name – – Detailed Description Low voltages may be the result of a problem with the voltage regulator or a problem with the processor. The low voltage may cause the processor to fail to operate.
Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message CPU voltage is outside of range. Reseat CPU Initial Default. LC Log Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0302 CPU arg1 arg2 voltage is greater than the upper warning threshold.
Detailed Description High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other system electrical components. The system may power down. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support.
VLT0305 CPU arg1 arg2 voltage is within range. Message Arguments – – arg1 = number arg2 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VLT = Voltage Severity Severity 3 (Informational) Trap/EventID 2171 LCD Message No LCD message display defined. Initial Default.
59 VME Event Messages VME0001 Message Virtual Console session started. Detailed Description Virtual Console session started. Recommended Response Action No response action is required. Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Detailed Description Virtual Console session fails to start. Recommended Response Action Retry the Virtual Console session initiation. Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VME0006 Message Virtual Media session exited. Detailed Description Virtual Media session exited. Recommended Response Action No response action is required. Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
60 VRM Event Messages VRM0009 Message No Virtual Media devices are currently connected. Detailed Description No virtual media was found to disconnect. Recommended Response Action No response action is required. Category System Health SubCategory VRM = Virtual Console Severity Severity 1 (Critical) LCD Message No LCD message display defined. Initial Default.
VRM0011 Message The Virtual Media image server is not currently connected. Detailed Description The Virtual Media server is already disconnected. Recommended Response Action No response action is required. Category System Health SubCategory VRM = Virtual Console Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VRM0014 Message Unable to determine current state of Virtual Media USB interface. Detailed Description Racadm tool was unable to get the status of the USB interface. Recommended Response Action No response action is required.
VRM0016 Message Virtual Console is DISABLED Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory VRM = Virtual Console Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) LCD Message No LCD message display defined. Initial Default. None Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VRM0019 Message Remote Image is now Configured Detailed Description The Remote Image is now configured and ready to use. Recommended Response Action No response action is required.