Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
VDR6
Message
arg1
configuration has changed.
Arguments
arg1 =
VD Name
Detailed Description This alert is provided for informational purposes.
Recommended Response Action No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR7
Message
arg1
has failed.
Arguments
arg1 =
virtual disk
Detailed Description One or more physical disks included in the virtual disk have failed. If the virtual disk is
non-redundant (does not use mirrored or parity data), then the failure of a single
physical disk can cause the virtual disk to fail. If the virtual disk is redundant, then more
physical disks have failed than you can rebuild using mirrored or parity information.
Recommended Response
Action
Create a new virtual disk and restore from a backup.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. None
1001