Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR8
Message
arg1
has become degraded.
Arguments
arg1 =
virtual disk
Detailed Description This message occurs when a physical disk in the disk group was removed or when a
physical disk included in a redundant virtual disk fails. Because the virtual disk is
redundant (uses mirrored or parity information) and only one physical disk has failed, the
virtual disk can be rebuilt.
Recommended Response
Action
Configure a hot spare for the virtual disk if it is not already configured. Rebuild the virtual
disk. If a physical disk was removed from the disk group, either replace the disk or restore
the original disk.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR9
Message
arg1
consistency check has started.
Arguments
arg1 =
virtual disk
Detailed Description A consistency check operation on a virtual disk has started.
Recommended Response Action No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
1002