Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR054
Message System Reset or System Services Canceled, System Profile Failure Recovery
unsuccessful.
Detailed Description The attempt to clean up after a failed Backup/Restore of a system profile operation has
failed. The System Services related operations may not execute as expected until the
system is properly cleaned.
Recommended Response
Action
Enter the iDRAC configuration utility. Select the System Services option in the main
selection screen. Choose the "Cancel System Services" operation and follow the
directions to ensure this operation is performed.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR055
Message Previously stored configuration values not applied to Device:
arg1
Arguments
arg1 =
device name
Detailed Description Attempted configuration import was not successful for the specified device.
Recommended Response Action The system event log captures the values that were not set, and must be reset
manually.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE