Reference Guide

Arguments
arg1 =
name
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe mode.
Recommended Response
Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3)
If the problem persists, contact technical support. Refer to the product documentation
to choose a convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID 2169
LCD Message Memory module <name> voltage is outside of range. Contact support
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
VLT0229
Message The memory module
arg1
voltage is within range.
Arguments
arg1 =
name
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID 2171
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0230
Message The mezzanine card
arg1
arg2
voltage is less than the lower warning threshold.
1037