Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0300
Message CPU
arg1
arg2
voltage is less than the lower warning threshold.
Arguments
arg1 =
number
arg2 =
name
Detailed Description Low voltages may be the result of a problem with the voltage regulator or a problem with
the processor. The low voltage may cause the processor to fail to operate.
Recommended Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power and
turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still
persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID 2170
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
VLT0301
Message CPU
arg1
arg2
voltage is less than the lower critical threshold.
Arguments
arg1 =
number
arg2 =
name
Detailed Description Low voltages may be the result of a problem with the voltage regulator or a problem with
the processor. When the critical threshold is crossed, the processor will fail to operate.
The system may power down.
Recommended Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists,
contact technical support. Refer to the product documentation to choose a convenient
contact method.
1041