Reference Guide

Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID 2169
LCD Message CPU <number> <name> voltage is outside of range. Reseat CPU
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
VLT0302
Message CPU
arg1
arg2
voltage is greater than the upper warning threshold.
Arguments
arg1 =
number
arg2 =
name
Detailed Description High voltages may be the result of problem with the voltage regulator or a problem with
the processor. Elevated voltages may result in damage to the processor or other
electronic components in side the system.
Recommended Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists,
contact technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID 2170
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
VLT0303
Message CPU
arg1
arg2
voltage is greater than the upper critical threshold.
Arguments
arg1 =
number
arg2 =
name
1042