Reference Guide

Trap/EventID 2227
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
BAT0007
Message The storage battery has failed.
Detailed Description The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended Response Action 1) Verify the PERC RAID controller battery installation. 2) Check the system logs for
thermal related issues.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Storage battery has failed. Check battery.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
BAT0008
Message The storage battery is present.
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID 2227
LCD Message No LCD message display defined.
Initial Default. LC Log
130