Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
BAT0009
Message The storage battery is absent.
Detailed Description The PERC RAID controller battery may report absent due to disconnect or thermal
exceptions.
Recommended Response Action 1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or
reconnect the battery and cables. 3) Check the system logs for thermal related
issues.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Storage battery is absent. Check battery.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
BAT0010
Message The storage battery for disk drive bay
arg1
is low.
Arguments
arg1 =
bay
Detailed Description The system has to remain powered on to charge the battery.
Recommended Response Action Allow the PERC RAID controller battery for the associated bay to charge. If the issue
persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
Trap/EventID 2226
LCD Message No LCD message display defined.
Initial Default. LC Log
131