Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
BAT0013
Message The storage battery for disk drive bay
arg1
is present.
Arguments
arg1 =
bay
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID 2227
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
BAT0014
Message The storage battery for disk drive bay
arg1
is absent.
Arguments
arg1 =
bay
Detailed Description The PERC RAID controller battery may report absent due to disconnect or thermal
exceptions.
Recommended Response Action 1) Verify the PERC RAID controller battery installation for the associated bay. 2) If
installed, reseat or reconnect the battery and cables. 3) Check the system logs for
thermal related issues.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Battery for disk drive bay <bay> is absent. Check battery.
Initial Default. LC Log
133