Reference Guide

BAT1018
Message Battery on
arg1
is degraded.
Arguments
arg1 =
Controller name
Detailed Description The temperature of the battery is high. This may be due to the battery being charged.
Recommended Response
Action
If the battery is being charged, then charging the battery should be stopped until the
battery cools down and charging should be resumed. If this is not case, then some
other condition exists and should be investigated.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
BAT1019
Message Battery on
arg1
is charging.
Arguments
arg1 =
Controller name
Detailed Description This alert is provided for informational purposes.
Recommended Response Action No response action is required.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
BAT1020
Message The
arg1
battery is executing a learn cycle.
145