Reference Guide

SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
Trap/EventID 4274
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
BAT1025
Message
arg1
is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments
arg1 =
controller name
Detailed Description The controller was unable to recover data from the cache. This may indicate data loss
has occurred.
Recommended Response
Action
Verify that the battery is charged and in good health. See the hardware documentation
for more information. When the battery charge is unacceptably low, the battery cannot
maintain cached data. Data loss may also have occurred, restoring data from backups
may be needed. Verify whether the battery has met its recharge limit. The battery may
need to be recharged. Contact technical support if the issue persists.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 4273
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
BAT1026
Message The
arg1
has recovered cached data from the Battery Backup Unit (BBU).
Arguments
arg1 =
controller name
Detailed Description The controller has retrieved cached data.
Recommended Response Action No response action is required.
148