Reference Guide

8
CBL Event Messages
CBL0001
Message Backplane
arg1
power cable disconnected.
Arguments
arg1 =
Bay ID
Detailed Description A backplane signal cable was detected, but the accompanying power cable was not
present.
Recommended Response Action Check backplane configuration. Re-connect cable. If the issue persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health
SubCategory CBL = Cable
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE TRUE FALSE FALSE FALSE
CBL0002
Message Backplane
arg1
signal cable disconnected.
Arguments
arg1 =
Bay ID
Detailed Description A backplane power cable was detected, but the accompanying signal cable was not
present.
Recommended Response Action Check backplane configuration. Re-connect cable. If the issue persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health
SubCategory CBL = Cable
Severity Severity 1 (Critical)
175