Reference Guide

CPU0025
Message CPU
arg1
terminator is absent.
Arguments
arg1 =
number
Detailed Description System is unable to boot or may run in a degraded state.
Recommended Response Action Check presence and reinstall the terminator.
Category System Health
SubCategory CPU = Processor
Severity Severity 2 (Warning)
Trap/EventID 2242
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
CPU0700
Message CPU
arg1
initialization error detected.
Arguments
arg1 =
number
Detailed Description System BIOS was unable to boot the processor.
Recommended Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power and
turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still
persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> initialization error detected. Power cycle system
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE