Reference Guide

LCD Message CPU <number> machine check error detected. Power cycle system
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
CPU0800
Message CPU
arg1
voltage regulator module is present.
Arguments
arg1 =
number
Detailed Description None
Recommended Response Action No response action is required.
Category System Health
SubCategory CPU = Processor
Severity Severity 3 (Informational)
Trap/EventID 2243
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CPU0801
Message CPU
arg1
voltage regulator module failed.
Arguments
arg1 =
number
Detailed Description System performance may be degraded or the system may fail to operate.
Recommended Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power and
turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still
persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> voltage regulator module failed. Reseat module
189