Reference Guide

SubCategory CPU = Processor
Severity Severity 2 (Warning)
Trap/EventID 2242
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CPU0806
Message CPU
arg1
voltage regulator module is incorrectly configure.
Arguments
arg1 =
number
Detailed Description System performance may be degraded or the system may fail to operate.
Recommended Response Action Review product documentation for proper configuration and installation procedures.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> voltage regulator module incorrectly configure. Check configuration
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CPU0816
Message CPU
arg1
voltage regulator module is absent.
Arguments
arg1 =
number
Detailed Description System performance may be degraded or the system may fail to operate.
Recommended Response Action if removal was unintended, check presence and re-install .
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
192