Reference Guide

Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL11
Message Configuration on
arg1
was reset.
Arguments
arg1 =
controller name
Detailed Description A user operation to reset the controller configuration was performed.
Recommended Response Action No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
Trap/EventID 4331
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL12
Message An invalid SAS configuration has been detected on
arg1
. Details:
arg2
Arguments
arg1 =
Controller name
arg2 =
error message
Detailed Description The controller and attached enclosures are not cabled correctly.
Recommended Response Action Refer to the storage hardware documentation for information on correct cabling
configurations.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
198