Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL13
Message The
arg1
cache has been discarded.
Arguments
arg1 =
Controller name
Detailed Description The controller has flushed the cache and all data in the cache has been lost. This may
occur when the system has memory or battery problems that cause the controller to
distrust the cache. Although user data may have been lost, this alert does not always
indicate that relevant or user data has been lost.
Recommended Response
Action
Verify that the battery and memory are functioning properly.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL14
Message Single-bit ECC error limit exceeded on the
arg1
DIMM.
Arguments
arg1 =
Controller name
Detailed Description The controller memory is malfunctioning.
Recommended Response Action Replace the controller, contact Dell technical support at support.dell.com.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
199