Reference Guide

SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CTL40
Message Multi-bit ECC error on
arg1
DIMM.
Arguments
arg1 =
Controller name
Detailed Description An error involving multiple bits has been encountered during a read or write operation. The
error correction algorithm recalculates parity data during read and write operations. If an
error involves only a single bit, it may be possible for the error correction algorithm to
correct the error and maintain parity data. An error involving multiple bits, however,
generally indicates data loss. In some cases, if the multi-bit error occurs during a read
operation, then the data on the disk may be ok. If the multi-bit error occurs during a write
operation, then data loss has occurred.
Recommended
Response Action
Replace the Dual In-line Memory Module (DIMM). The DIMM is a part of the controller
battery pack. Refer to the storage hardware documentation for information on replacing the
DIMM. You may need to restore data from backup.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL41
Message Single-bit ECC error on
arg1
.
Arguments
arg1 =
Controller name
Detailed Description An error involving a single bit has been encountered during a read or write
operation. The error correction algorithm has corrected this error.
212