Reference Guide

Recommended Response Action Replace the Dual In-line Memory Module (DIMM) to avoid data loss or data
corruption. The DIMM is a part of the controller battery pack. Refer to hardware
documentation for information on replacing the DIMM.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL46
Message Single-bit ECC error. The
arg1
DIMM is critically degraded.
Arguments
arg1 =
Controller name
Detailed Description The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data
corruption may occur..
Recommended Response
Action
Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a
part of the controller battery pack. Refer to the storage hardware documentation for
information on replacing the DIMM.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL47
Message Single-bit ECC error on
arg1
.
Arguments
arg1 =
Controller name
215