Reference Guide
CTL50
Message The
arg1
NVRAM has corrupt data.
Arguments
–
arg1 =
Controller name
Detailed Description The NVRAM has corrupt data. The controller is unable to correct the situation.
Recommended Response Action Replace the controller.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL51
Message
arg1
SAS port report:
arg2
Arguments
–
arg1 =
Controller name
–
arg2 =
message
Detailed Description The text for this message is generated by the controller during runtime and can vary
depending on the situation.
Recommended Response
Action
Make sure the SAS cables attached to the enclosure/backplane are attached
securely. Refer to the storage hardware documentation for more information on
checking the cables. Contact technical support if the issue persists.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE