Reference Guide

CTL58
Message
arg1
SAS SMP communications error
arg2
Arguments
arg1 =
Controller name
arg2 =
args
Detailed Description The text for this alert is generated by the firmware and can vary depending on the
situation. The reference to SMP in this text refers to SAS Management Protocol.
Recommended Response
Action
There may be a SAS topology error. See the hardware documentation for information on
correct SAS topology configurations. There may be problems with the cables such as a
loose connection or an invalid cabling configuration. See the Cables Attached Correctly
section for more information on checking the cables. See the hardware documentation for
information on correct cabling configurations. Verify that the firmware version is
supported.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL59
Message
arg1
SAS expander error:
arg2
Arguments
arg1 =
Controller name
arg2 =
args
Detailed Description There may be a problem with the enclosure. Verify the health of the enclosure and its
components. To verify the health of the enclosure, select the enclosure object in the tree
view. The Health subtab displays a red X or yellow exclamation point for enclosure
components that are failed or degraded. See the enclosure documentation for more
information.
Recommended
Response Action
There may be a problem with the enclosure. Verify the health of the enclosure and its
components. To verify the health of the enclosure, select the enclosure object in the tree
view. The Health subtab displays a red X or yellow exclamation mark for enclosure
components that are failed or degraded. See the enclosure documentation for more
information.
222