Reference Guide

Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CTL61
Message Physical disks found missing from configuration during boot time on
arg1
.
Arguments
arg1 =
Controller name
Detailed Description The controller has detected a change in the storage configuration between since its
last shut down. This can generally happen if some configured physical disks are
removed from the system when the system was shutdown.
Recommended Response
Action
Shut down the system. Re-insert the removed physical disks and re-start the system.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL62
Message
arg1
on
arg2
has missing drives and will go offline at boot.
Arguments
arg1 =
VD names
arg2 =
Controller name
Detailed Description Physical disk(s) have been removed from a virtual disk. The virtual disk will be in
Failed state during the next system reboot. This alert is provided for informational
purposes.
Recommended Response Action No response action is required.
Category Storage
224