Reference Guide

SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
CTL75
Message Preserved cache discarded on
arg1
.
Arguments
arg1 =
controller name
Detailed Description The controller cache was discarded by the user.Data may have been lost or
corrupted.
Recommended Response Action If data was corrupted or lost, restore the data to the disk from a backup copy.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CTL76
Message A configuration command could not be committed to disk on
arg1
Arguments
arg1 =
Controller name
Detailed Description The controller encountered errors while applying the configuration on the physical
disks. The configuration command applied has not taken effect.
Recommended Response Action Re-issue the failed configuration command or try with a different set of physical
disks. Contact technical support if the problem persists.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
231