Reference Guide

ENC17
Message An Enclosure Management Module (EMM) has been discovered on
arg1
.
Arguments
arg1 =
Enclosure Name
Detailed Description This alert is provided for informational purposes.
Recommended Response Action No response action is required.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ENC18
Message Communication with
arg1
was lost.
Arguments
arg1 =
enclosure name
Detailed Description The controller has lost communication with an Enclosure Management Module
(EMM). The cables may be loose or defective.
Recommended Response Action Make sure the cables are attached securely. See the storage hardware
documentation for more information on checking the cables. Reboot the system.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE