Reference Guide

ENC24
Message Communication with
arg1
is intermittent.
Arguments
arg1 =
enclosure name
Detailed Description The controller is not receiving a consistent response from the enclosure.There could
be a firmware problem or an invalid cabling configuration.If the cables are too long,
they degrade the signal.
Recommended Response
Action
Power down all enclosures attached to the system and reboot . If the problem persists,
upgrade the firmware to the latest supported version. Verify the cable configuration is
valid. See the storage hardware documentation for valid cabling configurations.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
ENC25
Message
arg1
has a hardware error.
Arguments
arg1 =
enclosure name
Detailed Description The enclosure or an enclosure component is in a Failed or Degraded state.
Recommended Response Action Verify the health of the enclosure and its components. See the storage hardware
documentation for more information. Contact technical support.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default. SNMP Alert
259