Message
arg1
firmware mismatch.
Arguments
arg1 =
Enclosure Name
Detailed Description The firmware on the EMM modules is not the same version. It is required that both
modules have the same version of the firmware. This alert may be caused when you
attempt to insert an EMM module that has a different firmware version than an existing
module.
Recommended Response
Action
Download the same version of the firmware to both EMM modules.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ENC40
Message A new enclosure was detected on
arg1
.
Arguments
arg1 =
controller name
Detailed Description The controller detected a new enclosure. This is due either to a hot plug of an
enclosure, or a power state change of an enclosure. In addition, this message is
generated if the daisy chain order of the enclosures changes.
Recommended Response Action No response action is required.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
Trap/EventID 4339
LCD Message No LCD message display defined.
Initial Default. SNMP Alert