Reference Guide

Detailed Description Dell has authorized the specified debug capabilities. Each debug capability represents
a certain action Dell engineers can perform to debug iDRAC.
Recommended Response
Action
No response action is required.
Category Audit
SubCategory FSD=Debug
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD OS Log Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE TRUE FALSE FALSE FALSE
FSD002
Message Debug authorization failed; for debugCaps:
arg1
, authorized by iDRAC user:
arg2
, and Dell
employee:
arg3
, at
arg4
for the period:
arg5
to
arg6
.
Arguments
arg1 =
DebugCaps
arg2 =
IDRAC user
arg3 =
Dell employee
arg4 =
unblock time
arg5 =
start time
arg6 =
end time
Detailed Description A RACADM Debug command failed. If the RACADM Debug command was executed under the
direction of Dell tech support then further assistance from tech support should be requested.
Otherwise this command is not intended for customer use.
Recommended
Response Action
Verify all of the following 1) ensure that the unblock, grant, and invoke/start/stop/resume
commands are all executed against the same iDRAC. 2) ensure dat.ini file has not been
changed in any way. 3) ensure that current date falls between the start and end times. Note
that Dell can further restrict both the set of debugCaps that is authorized and the start and
stop times. If an authorized person did not enter a RACADM debug command then an attacker
may have entered the command.
Category Audit
SubCategory FSD=Debug
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default. LC Log
278